Report · houses built in
What a house built in 1975 often has
- Age
- 51yrs
- On record
- 37
- Check first
- 6
- Built without
- 12
Choose one to hide issues that only apply elsewhere.
Headline findingCheck first
Federal Pacific Stab-Lok panels
1950–1990 · 1975 is in the peak yearsApproximate era: Dates are an approximate era drawn from trade and reference sources.
Federal Pacific Stab-Lok breaker panels were made from 1950 to 1980, and CPSC's own testing found breakers that failed calibration tests.
37 things on record apply to a 1975 house: 6 to check first, 12 protections it was built without, and 20 more by part of the house.
Where 1975 sits among every issue on record
Point at a band to read it · drag or use the arrow keys to compare yearsWhat the 1975 line crosses37 bands
- Electrical
- Federal Pacific Stab-Lok panels (check first)
- Aluminum branch wiring (check first)
- Garage door opener without auto-reverse (built without)
- Zinsco and Sylvania-Zinsco panels
- Missing GFCI shock protection (built without)
- No arc-fault (AFCI) breakers (built without)
- Outlets without child-safety shutters (built without)
- Split-bus panels with no main breaker
- Hazardous materials
- Lead paint (check first)
- Lead water service line (check first)
- Vermiculite attic insulation (check first)
- Asbestos floor tile and sheet flooring
- Asbestos in drywall joint compound
- Asbestos in popcorn ceilings
- Lead solder in copper water pipes
- Asbestos pipe and boiler insulation
- Arsenic-treated (CCA) deck lumber
- Asbestos-cement siding and shingles
- Chlordane termite treatment
- PCBs in old fluorescent light ballasts
- Urea-formaldehyde foam insulation (UFFI)
- Roof, walls & windows
- Structure
- Heating & cooling
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
Check these first
The 6 items most worth a look in a 1975 house: safety first, then cost.
Federal Pacific Stab-Lok panels
Federal Pacific Stab-Lok breaker panels were made from 1950 to 1980, and CPSC's own testing found breakers that failed calibration tests.
How to checkElectrical panel
- Open the panel door (not the inner cover) and read the label for 'Federal Pacific Electric', 'FPE' or 'Federal Pioneer'.
- Look for 'Stab-Lok' printed on or near the breakers.
- Breaker handles often have a red or orange stripe across the tip.
If you find itHave a licensed electrician inspect it. Replacing the whole panel is the usual fix. There was never a recall, so there is no manufacturer remedy.
How commonNo reliable count exists. Claims of 'millions of homes' come from advocacy sources, and no market-share data was found.
Keep in mindCPSC closed its investigation without a finding either way, saying it had too little data to accept or refute the maker's position. The widely quoted failure rates come from independent testing that could not be checked, and the production years come from a reference source, not from CPSC.
Details and 6 sources →1950–19901975 is in the peak years
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsMissing or outdated smoke alarms
Model building codes began requiring smoke alarms in every bedroom, linked so one sets off the rest, in 1988, so many older houses were built with far fewer.
How to checkWhole house
- Count them: one in each bedroom, one outside each sleeping area, and one on every level including the basement.
- Press TEST on one: if all of them sound, they are interconnected.
- Twist one off its base: a wiring plug behind it means hard-wired; none means battery-only.
- Check the manufacture date on the back; over 10 years old means replace it.
If you find itAdd alarms to every bedroom, hallway and level, using interconnected units; wireless interconnected alarms avoid new wiring. Replace any alarm over 10 years old.
How commonNo reliable count exists of houses with alarms in every bedroom. NIST: the share of homes with at least one smoke alarm rose from 10% in 1975 to at least 92% by 2000.
Keep in mindThe code dates come from reference sources and varied by code family and local adoption, so 1988 to 1993 is a transition and later is possible. Many older houses have been upgraded since.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 5 sources →Built 1995 or earlier1975 is in the peak years
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsAluminum branch wiring
From 1965 to the mid-1970s, some houses were wired with solid aluminum instead of copper, and CPSC reports that pre-1972 aluminum-wired homes were 55 times more likely to have one or more outlet connections reach fire-hazard conditions.
How to checkWiring & outlets · Electrical panel · Attic · Basement & foundation
- Look at any exposed cable in the attic, basement or near the panel for 'AL' or 'ALUMINUM' printed on the plastic jacket every few feet.
- Cable marked 'CU-clad' or 'copper-clad' uses copper-coated aluminum wire and is not covered by CPSC's aluminum repair advice; ask an electrician about it.
- Warning signs: cover plates that feel warm, flickering lights, or a smell of burning plastic at an outlet.
- Do not open outlet or switch boxes yourself.
If you find itCall a licensed electrician who uses one of the three permanent repairs CPSC approves: rewiring with copper, COPALUM crimp connectors, or AlumiConn connectors. CPSC calls CO/ALR outlets and switches at best an incomplete repair, and says twist-on pigtail connectors do not solve the overheating problem. If you notice warm plates or a burning smell, stop using that circuit until it is checked.
How commonCPSC estimated in 1974 that about two million homes and mobile homes had been built with aluminum wiring since 1965. No figure gives the share of houses of the era.
Keep in mindCPSC's hazard figure covers homes built before 1972, and it developed no information on aluminum-wired homes built after that. CPSC says homes built before 1965 are unlikely to have aluminum branch wiring and that cable installed from 1965 to the mid 1970s may contain it, so the end year is soft.
Details and 12 sources →1965–1975most likely 1965–1972
Approximate era: Dates are an approximate era drawn from trade and reference sources.PossibleLead paint
EPA says 87% of homes built before 1940 have some lead-based paint, and lead paint for homes was banned only in 1978.
How to checkWalls, ceilings & floors · Windows · Exterior walls · Whole house
- You cannot identify lead paint by sight; it takes an XRF test by a certified inspector or a lab paint-chip test.
- The most likely places are original windows, doors, trim, porches and exterior siding.
- Warning signs are many layers of old paint, a cracked 'alligator' pattern, or chalking.
If you find itIf young children live in the house or you plan to renovate, get a lead inspection or risk assessment. Under EPA's Renovation, Repair and Painting rule, anyone paid to disturb paint in a pre-1978 home must be certified; the rule generally does not apply to owners working on their own home. Options range from stabilizing and repainting to abatement by certified firms; do not dry-sand or scrape old paint yourself.
How commonEPA: 87% of homes built before 1940 and 24% of homes built from 1960 to 1978 have some lead-based paint. HUD's national survey found it in 34.6 million homes, 29.4% of all US housing.
Keep in mindPaint made before the ban could still be applied in 1978 and a little later. Most houses built from 1960 to 1978 do not have lead paint; the share is far higher in older houses.
Details and 9 sources →Built 1978 or earliermost likely up to 1939
Federal rule: Dates come from a federal rule or a model building code.LikelyLead water service line
The pipe that brings water from the street into many older houses is made of lead, and EPA estimates about 4 million of these lines are still in use.
How to checkWater pipes · Basement & foundation
- Find where the water pipe enters the house, usually in the basement or crawl space near the meter.
- Lead is dull gray and soft: scratch it gently with a coin or key and it shows shiny silver. A magnet will not stick, and joints often have a bulging 'wiped' shape.
- Galvanized steel is gray but hard and magnetic; copper is the color of a penny.
- Look up your address in the water utility's public service line inventory.
If you find itIf you find lead, or the utility lists your line as lead or unknown, use a filter certified to NSF/ANSI 53 for lead for drinking and cooking water, and ask the utility about replacement programs. EPA puts full replacement at $1,200 to $12,300 per line, averaging $4,700. Replace the whole line, not just part of it.
How commonEPA's 2025 estimate is about 4 million lead service lines nationwide, a count that includes galvanized lines EPA treats as lead; its 2023 survey estimated 9.2 million. They are concentrated in older cities, and no figure gives the share by build year.
Keep in mindWhether a given house has a lead line depends much more on the city than on the year: a trade source says lead was rarely used after about 1950, but the federal ban did not come until 1986. EPA's national estimates have also changed sharply between surveys.
Details and 9 sources →Built 1986 or earliermost likely up to 1950
Federal rule: Dates come from a federal rule or a model building code.PossibleVermiculite attic insulation
Loose, pebbly vermiculite insulation in the attic, often sold as Zonolite, may contain asbestos, and EPA advises treating it as if it does.
How to checkAttic
- Look into the attic from the hatch without stepping in or disturbing anything.
- Vermiculite is loose, lightweight granules about 1/8 to 1/2 inch, shiny and accordion-like, gray-brown to silver-gold, lying between the joists.
- It is often under newer fiberglass or cellulose. InterNACHI tells inspectors that empty Zonolite bags left in the attic are a clue.
- EPA advises against relying on a negative lab test.
If you find itLeave it undisturbed, keep boxes and other stored items out of that attic, and do not try to remove it yourself. EPA advises hiring a professional asbestos contractor before any remodeling that would disturb it. Zonolite Attic Insulation claims against W.R. Grace were settled in its bankruptcy; this guide could not confirm whether any reimbursement is still offered.
How commonWikipedia reports a US government estimate that vermiculite was used in more than 35 million homes; other estimates are far lower. Even the high figure is a minority of houses.
Keep in mindThis was largely a do-it-yourself product added to existing houses, so build year is a weak guide. Most houses do not have it, and estimates of how many do disagree widely.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 10 sources →Built 1990 or earlier
Approximate era: Dates are an approximate era drawn from trade and reference sources.Possible
Built without
Protections that became standard after 1975. A house keeps what it was built with unless someone added them, and many have been.
Garage door opener without auto-reverse
Garage door openers made before 1991 did not have to reverse when they hit something, and photo-eyes or similar protection became required on openers made from 1993.Garage door openers made before 1991 did not have to reverse when they hit something, and photo-eyes or similar protection became required on openers made from 1993.
Read the full entry →Built 1992 or earlier1975 is in the peak years
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Look for two small sensor 'eyes' near the floor on each side of the garage door opening.
- Check the date on the opener's label.
- Test it: lay a 2x4 flat on the floor under the door; the door should reverse when it touches the board.
If you find itIf the opener does not reverse or has no sensors, replace it with a current UL 325-compliant unit rather than trying to retrofit it. Until then, keep children clear of the door while it moves.
How commonNo reliable count exists of pre-1993 openers still in use.
Keep in mindThe 1993 rule can be met by a constant-contact wall button instead of photo-eyes, so a newer opener without eyes is possible. Openers are often added or replaced long after a house is built.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 4 sources →Non-tempered glass in doors and showers
Glass in doors, sliding patio doors and shower enclosures has had to be safety glass since July 1977, so older original glass may be ordinary glass that can cause serious cuts if someone falls through it.Glass in doors, sliding patio doors and shower enclosures has had to be safety glass since July 1977, so older original glass may be ordinary glass that can cause serious cuts if someone falls through it.
Read the full entry →Built 1977 or earlier1975 is in the peak years
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Look in each corner of the glass in doors, sliding doors and shower panels for a small etched or sandblasted mark naming the maker.
- A mark reading 'tempered', '16 CFR 1201' or 'ANSI Z97.1' means safety glass.
- No mark on a door or shower panel in an older house suggests ordinary glass.
If you find itReplace unmarked glass in doors and showers with tempered or laminated safety glass, starting with the places people are most likely to fall against.
How commonNo reliable count exists of original pre-1977 glass still in place.
Keep in mindSome states may have had their own safety-glazing laws earlier; that was not confirmed. Many doors and shower enclosures have been replaced since 1977.
Details and 3 sources →Florida home built before the statewide wind code
Florida homes built before the statewide Florida Building Code took effect on March 1, 2002 were built to earlier local codes; the statewide code followed Hurricane Andrew.Florida homes built before the statewide Florida Building Code took effect on March 1, 2002 were built to earlier local codes; the statewide code followed Hurricane Andrew.
Read the full entry →Built 2002 or earlier
Approximate era: Dates are an approximate era drawn from trade and reference sources.LikelyHow to check
- In the attic at the eaves, look where each truss or rafter meets the top of the wall.
- Only angled nails means toe-nailed; a small metal bracket is a clip; a metal strap wrapping over the truss is a wrap, and two straps a double wrap.
- Check windows and doors for impact-rated labels or shutter hardware.
- Your county permit record gives the original permit date.
If you find itGet a wind-mitigation inspection by a licensed inspector; it records these features for your insurer. Upgrades such as roof-to-wall straps, re-nailing the roof deck and shutters are usually done at re-roofing time.
How commonWikipedia puts the number of Florida homes that predate the modern code at about 4.7 million; every Florida home built before March 2002 predates it.
Keep in mindHouses finished around 2002 can go either way, depending on when they were approved. In South Florida's High-Velocity Hurricane Zones the stricter code dates from 1994. Some pre-2002 homes do have clips or straps.
Details and 4 sources →Gas water heaters made before 2003 (no flammable-vapor protection)
Standard gas tank water heaters made after July 1, 2003 are built to resist igniting gasoline fumes; older ones are not.Standard gas tank water heaters made after July 1, 2003 are built to resist igniting gasoline fumes; older ones are not.
Read the full entry →Built 2003 or earlier
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Check whether the water heater is a gas tank model (a burner at the bottom and a vent pipe on top).
- Read the label for the words 'Flammable Vapor Ignition Resistant' or 'FVIR'.
- Look for the manufacture date in the label or serial number: after July 2003 means it should have the protection.
- Notice whether gasoline, paint thinner or solvents are stored near it, especially in a garage.
If you find itKeep gasoline and solvents well away from any gas appliance. If the heater predates the standard, plan to replace it with a current model.
How commonAny gas tank heater made before July 2003 lacks it. Many heaters that old have been replaced; no count of how many remain exists.
Keep in mindThis was a voluntary industry standard, not a federal law, and it covers standard 30, 40 and 50 gallon gas tank heaters. Water heaters are replaced often, so the heater's own date matters far more than the house's.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 4 sources →Missing GFCI shock protection
CPSC says houses built before 1973 have no GFCI shock protection unless it was added later, and the code then added it one area at a time: bathrooms in 1975, garages in 1978, some kitchen outlets in 1987.CPSC says houses built before 1973 have no GFCI shock protection unless it was added later, and the code then added it one area at a time: bathrooms in 1975, garages in 1978, some kitchen outlets in 1987.
Read the full entry →Built 1992 or earliermost likely up to 1972
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Look for outlets with TEST and RESET buttons in bathrooms, at kitchen counters, in the garage, outdoors, in the basement and in the laundry.
- Check the panel for breakers with a test button; a GFCI breaker protects a whole circuit.
- One GFCI can protect ordinary-looking outlets further along the circuit: press TEST and see which outlets go dead.
- Press RESET afterwards. A GFCI that does not trip when you press TEST needs replacing.
If you find itAn electrician can add GFCI outlets or breakers where they are missing; they are allowed on ungrounded circuits too. Replace any GFCI that does not trip when tested.
How commonNo reliable count exists on how many older houses have had GFCIs added. CPSC notes that houses built before 1973 have no GFCI protection unless it was installed later.
Keep in mindThese are national code edition years. States and cities adopted each edition anywhere from the same year to several years later, so a house built just after a milestone may not have that protection. Many older houses have had GFCIs added since, so build year is only a rough guide.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 4 sources →Mobile home built before the HUD Code
Mobile homes made before June 15, 1976 predate the federal HUD Code and cannot get FHA-insured mortgages.Mobile homes made before June 15, 1976 predate the federal HUD Code and cannot get FHA-insured mortgages.
Read the full entry →Built 1976 or earlier
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Look for a metal certification label, about 2 by 4 inches, riveted to the outside at the tail end of each section.
- Look for a paper data plate inside, often in a kitchen cabinet, the electrical panel or a bedroom closet, giving the manufacture date.
- No label and no data plate, plus a title showing a pre-1976 year, means pre-HUD Code.
If you find itFocus on safety upgrades such as smoke alarms, a wiring evaluation and tie-downs. Expect financing limits: FHA insures only manufactured homes built on or after June 15, 1976, and HUD says a removed label cannot be reattached to make a home eligible.
How commonNo reliable count exists of surviving pre-1976 units. Every mobile home made before the date predates the HUD Code by definition.
Keep in mindThe date is when the home left the factory, not its model year or when it was placed, so a '1976' home can fall on either side.
Details and 6 sources →No arc-fault (AFCI) breakers
Arc-fault breakers, which detect the sparking that can start wiring fires, were first required in bedrooms of new houses in 2002.Arc-fault breakers, which detect the sparking that can start wiring fires, were first required in bedrooms of new houses in 2002.
Read the full entry →Built 2004 or earlier1975 is in the peak years
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Open the panel door and look for breakers with a TEST button labeled AFCI, 'Arc Fault', 'Combination AFCI' or 'Dual Function'.
- Ordinary breakers have no test button.
If you find itThis is an optional upgrade: an electrician can fit AFCI or dual-function breakers where your panel supports them.
How commonNo reliable count exists. Houses built before about 2002 will lack AFCIs unless they were added later.
Keep in mindStates adopt each code edition on their own schedule, so build year is a weak guide on its own. Only the 2002 bedroom date is confirmed by a primary source.
Details and 2 sources →Outlets without child-safety shutters
Since the 2008 electrical code, new houses get outlets with built-in shutters that stop a child pushing a key or hairpin into the slot.Since the 2008 electrical code, new houses get outlets with built-in shutters that stop a child pushing a key or hairpin into the slot.
Read the full entry →Built 2010 or earlier1975 is in the peak years
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Look closely at an outlet: 'TR' embossed on the face between the slots means tamper-resistant.
- You can see plastic shutters inside the slots.
If you find itIf small children live in or visit the house, have outlets replaced with TR-listed ones.
How commonNo reliable count exists. Houses built before their state adopted the 2008 code will generally lack them unless outlets were replaced.
Keep in mind2008 is the model code year; states adopted it at different times. As of 2016, the rule did not apply to manufactured homes.
Details and 3 sources →Manufactured home built before 1994 wind standards
After Hurricane Andrew, HUD raised the wind standards for manufactured homes made from July 13, 1994, with zones designed for 100 and 110 mph winds.After Hurricane Andrew, HUD raised the wind standards for manufactured homes made from July 13, 1994, with zones designed for 100 and 110 mph winds.
Read the full entry →Built 1994 or earlier
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Find the data plate inside the home, often in a kitchen cabinet, the electrical panel or a bedroom closet.
- Read the manufacture date and the wind-zone map showing which zone (I, II or III) the home was designed for.
- No wind-zone designation, or a date before July 1994, means the older standard.
If you find itHave the anchoring and tie-downs checked and brought up to current installation standards. Only replacement gets you the post-1994 structural design.
How commonNo reliable count exists. Every manufactured home made before the date was built to the older standard.
Keep in mindDate of manufacture governs, not the year the home was placed. Exactly which counties fall in each wind zone was not confirmed; the higher zones cover the hurricane coast.
Details and 2 sources →Built before energy codes
The first US energy standard for buildings, ASHRAE 90, was published in 1975, so a house built before then was not built to any energy code.The first US energy standard for buildings, ASHRAE 90, was published in 1975, so a house built before then was not built to any energy code.
Read the full entry →Built 1979 or earliermost likely up to 1974
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Look in the attic at the depth of insulation between and over the joists.
- Check what kind of glass the windows have: single pane or double pane.
If you find itAn energy audit shows where the house loses heat. Air sealing and attic insulation usually come first, then wall insulation.
How commonNo reliable count exists of how many older houses have been upgraded. A house built before 1975 was built without any energy code.
Keep in mind1975 is when the first standard was published, not when your state enforced one, and states adopted energy codes on their own schedules. Later code dates were not confirmed.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 4 sources →Built before mandatory airtightness testing (2012 energy code)
The 2012 energy code was the first to make new houses pass a whole-house air leakage test.The 2012 energy code was the first to make new houses pass a whole-house air leakage test.
Read the full entry →Built 2015 or earlier
Federal rule: Dates come from a federal rule or a model building code.LikelyHow to check
- Look near the electrical panel or furnace for an energy code certificate or a posted blower-door test result.
- Ask the seller or builder whether a blower-door test or energy rating was done.
- Notice drafts around outlets, attic hatches, recessed lights and window trim on a cold or windy day.
If you find itNothing is required. If the house feels drafty or bills are high, an energy audit with a blower-door test shows where air sealing would help most.
How commonHouses built before their state adopted the 2012 code were not required to pass this test. Adoption dates by state were not researched.
Keep in mindThis is a model code. States and cities adopted it at different times, so the end year here is stretched a few years and is soft. Check your state's adoption date.
Details and 3 sources →
Everything else, by part of the house
Materials and products often installed in 1975. Open any row for how to check.
Where to look. Each number counts the items in this report for that part of the house.
Electrical2
Zinsco and Sylvania-Zinsco panels
Zinsco panels, made from 1943 until about 1981 and later sold under the Sylvania name, have narrow breakers with brightly colored tips, and inspectors treat them as a problem panel.Zinsco panels, made from 1943 until about 1981 and later sold under the Sylvania name, have narrow breakers with brightly colored tips, and inspectors treat them as a problem panel.
Read the full entry →1943–19811975 is in the peak years
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Open the panel door and read the label for Zinsco, Sylvania, Sylvania-Zinsco or GTE-Sylvania.
- The breakers are distinctive: narrow, with brightly colored handle tips (red, blue, green or yellow), clipped onto vertical bus bars.
If you find itHave a licensed electrician evaluate the panel. Replacing the whole panel is the usual fix, because new breakers do not change the bus design.
How commonNo reliable count exists, and no checked source shows where they were most common.
Keep in mindThe dates rest mainly on one reference article, and the failure rates that circulate come from non-government testing. Plenty of these panels are still working, but InterNACHI treats the brand as one to have checked.
Details and 2 sources →Split-bus panels with no main breaker
Between the 1950s and the mid-1980s, many houses got a split-bus panel, which has no single main breaker: shutting off all the power can take up to six switches.Between the 1950s and the mid-1980s, many houses got a split-bus panel, which has no single main breaker: shutting off all the power can take up to six switches.
Read the full entry →1950–19851975 is in the peak years
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Open the panel door: there is no single large breaker marked 'Main'.
- Instead you see a top group of up to six double-pole breakers, one often labeled 'Lighting Main' or 'Sub Main', and a separate lower group of single-pole breakers.
- Read the brand on the label too, and check it against the Federal Pacific and Zinsco entries.
If you find itMake sure the breakers that shut off the house are clearly labeled. Have an electrician inspect it, and plan to replace it with a main-breaker panel when its condition calls for it or you add big loads such as an EV charger or heat pump.
How commonNo reliable count exists, and the share of houses of the era with one is unknown.
Keep in mindThe end date comes from one trade source ('mid-1980s'); the claim that a 1981 code change ended the design was not confirmed. Many of these panels have already been replaced.
Details and 1 source →
Plumbing & water1
Lead solder in copper water pipes
Copper water pipes installed before mid-1986 were commonly joined with lead solder, and EPA says solder and old brass fixtures are the most common lead source in homes without a lead service line.Copper water pipes installed before mid-1986 were commonly joined with lead solder, and EPA says solder and old brass fixtures are the most common lead source in homes without a lead service line.
Read the full entry →1930–19881975 is in the peak years
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Look at exposed copper pipe joints in the basement, at the water heater or under sinks. Old lead solder is dull gray and lead-free solder is brighter silver, but age blurs the difference.
- A lead swab test kit on a cleaned joint gives a better answer.
- The most reliable check is a first-draw water test through your utility or a certified lab.
If you find itTest your water. If lead shows up, run the cold tap before drinking, use cold water for cooking, and use a filter certified to NSF/ANSI 53 for lead. Replacing old brass faucets with post-2014 ones helps; repiping for solder alone is rarely needed.
How commonNo reliable count exists of how many houses built before the ban still have lead-solder joints.
Keep in mindThe federal ban took effect in June 1986, but states had until June 1988 to enforce it, so houses built from 1986 to 1988 are a gray zone. Copper has been used since the 1930s, and many older houses have been partly or fully repiped.
Details and 8 sources →
Kitchen & bath4
Asbestos floor tile and sheet flooring
CPSC says asbestos is found in some vinyl floor tiles, sheet-flooring backing and flooring adhesives, and that sanding tiles or scraping the backing can release fibers.CPSC says asbestos is found in some vinyl floor tiles, sheet-flooring backing and flooring adhesives, and that sanding tiles or scraping the backing can release fibers.
Read the full entry →1920–19861975 is in the peak years
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Look under carpet, in basements and closets, and under newer floor layers for old resilient tiles or sheet vinyl. Size and color do not tell you whether it contains asbestos.
- Note any black, tar-like 'cutback' adhesive under old tile; CPSC lists flooring adhesives as a possible source.
- Sheet flooring with a gray or white felt-like backing from before the mid-1980s is suspect.
- Only a lab test confirms it.
If you find itThe most common approach is to leave it in place and cover it with new flooring. Never sand it. If it has to come up, test first and use a licensed abatement contractor.
How commonNo reliable count exists. Resilient flooring was very common in mid-century kitchens, baths and basements, and some but not all products contained asbestos.
Keep in mindInstall years come from inspector references, not an agency, and manufacturers stopped at different times. Many tiles of the era contain no asbestos.
Details and 5 sources →Kidde plastic-handle fire extinguishers (2017 recall)
Kidde recalled about 37.8 million fire extinguishers because some may not spray when you need them.Kidde recalled about 37.8 million fire extinguishers because some may not spray when you need them.
Read the full entry →1973–2017
Court record: Dates come from a court settlement or a product recall.No reliable count existsHow to check
- Look under the kitchen sink, in the pantry, garage and utility room for any Kidde extinguisher.
- Note whether it has a plastic handle (red, white or silver models) or a push-button Pindicator top.
- Read the model number on the label and compare it with the model list on the CPSC recall notice.
- On units made in 2007 or later, a 10-digit date code is printed on the side of the cylinder near the bottom.
If you find itIf the model is on the list, replace it and contact Kidde through the product safety recall page on kidde.com. Check the recall notice for whether the replacement offer is still open.
How commonAbout 37.8 million units were recalled in the US; no count of affected homes exists.
Keep in mindExtinguishers are bought, not built in, so the year a house was built predicts little: owners add them to houses of every age. The recall did not cover every Kidde extinguisher, only the listed models.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 4 sources →Uncoated brass gas appliance connectors
Old flexible brass gas connectors behind stoves, dryers and water heaters can crack, and CPSC linked them to 35 deaths.Old flexible brass gas connectors behind stoves, dryers and water heaters can crack, and CPSC linked them to 35 deaths.
Read the full entry →Built 1986 or earlier
Court record: Dates come from a court settlement or a product recall.No reliable count existsHow to check
- CPSC says not to move a gas appliance to look; check only where the connector is already visible.
- An old connector is a dull brass-colored corrugated tube with no gray or yellow plastic coating.
- Modern connectors are stainless steel or coated.
If you find itHave a qualified gas technician check the connectors on older appliances and replace any uncoated brass one. A connector should never be reused.
How commonNo reliable count exists. Connectors are usually replaced with the appliance.
Keep in mindCPSC gave no exact year manufacture stopped, only 'at least the past 10 years' as of 1996. The age of the appliance matters more than the age of the house.
Details and 2 sources →High-flow toilets and showerheads
Since 1994, new toilets can use only 1.6 gallons per flush, less than half the water of most models in use before then.Since 1994, new toilets can use only 1.6 gallons per flush, less than half the water of most models in use before then.
Read the full entry →Built 1993 or earlier
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Lift the toilet tank lid: the gallons per flush is usually stamped or printed inside the tank, or on the bowl behind the seat, with a manufacture date.
- '1.6 gpf / 6.0 Lpf' or lower means it meets the 1994 rule.
- No marking and a large tank suggest a pre-1994 toilet.
If you find itIf you want lower water bills, replace with a WaterSense-labeled toilet and showerhead, and check whether your utility offers a rebate.
How commonNo reliable count exists. Toilets and showerheads are replaced often, so many older houses already have newer ones.
Keep in mindThe rule applied to fixtures made from January 1, 1994, so houses finished in 1994 may still have older stock. Fixtures are swapped so often that build year predicts this poorly.
Details and 3 sources →
Inside the walls & rooms2
Asbestos in drywall joint compound
Drywall joint and patching compound could contain asbestos until CPSC banned it in 1978, and you cannot tell by looking.Drywall joint and patching compound could contain asbestos until CPSC banned it in 1978, and you cannot tell by looking.
Read the full entry →1945–19781975 is in the peak years
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- This cannot be seen. Any drywalled or refinished wall or ceiling from before about 1980 is a candidate.
- Before sanding or demolition, have a lab test the joint compound layer itself, not just the board.
If you find itLeave intact walls alone. Test before renovating; if it is positive, use a licensed abatement contractor or your state's approved wet methods for the affected areas.
How commonNo reliable count exists of how many houses have it. CPSC says asbestos may be present in both textured paint and the patching compounds used on wall and ceiling joints.
Keep in mindThe ban covered consumer products, so contractor stock and already-purchased material may have been used for a while after 1978. The start year is approximate, tied to the spread of drywall after World War II.
Details and 4 sources →Asbestos in popcorn ceilings
Bumpy 'popcorn' ceilings put up through the 1980s sometimes contain asbestos, and CPSC says you cannot tell by looking, so treat it as if it does or have a professional test it.Bumpy 'popcorn' ceilings put up through the 1980s sometimes contain asbestos, and CPSC says you cannot tell by looking, so treat it as if it does or have a professional test it.
Read the full entry →1950–19851975 is in the peak years
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Look up: a bumpy, cottage-cheese-like sprayed texture, sometimes with glitter, is the type to ask about.
- You cannot see asbestos. A small sample has to go to an accredited lab (PLM analysis).
- Do not scrape or sample it yourself: CPSC says taking samples yourself is not recommended. Leave sampling to a qualified asbestos professional.
If you find itIf it is intact, leaving it alone is usually best, as CPSC advises for asbestos in good condition. Test before you remove or disturb it; if it is positive, it can be sealed, covered with new drywall, or removed wet by a licensed abatement contractor.
How commonNo reliable count exists of popcorn ceilings or of how many contain asbestos.
Keep in mindThe 1950 start and the 1980s tail are approximate; no primary source gives residential install years. A ceiling re-textured later may differ from the age of the house.
Details and 6 sources →
Heating, cooling & chimney1
R-22 (Freon) air conditioner
Since January 1, 2010, EPA has barred making new air conditioners or pre-charged parts with R-22, and US production and import of the refrigerant ended in 2020.Since January 1, 2010, EPA has barred making new air conditioners or pre-charged parts with R-22, and US production and import of the refrigerant ended in 2020.
Read the full entry →Built 2009 or earlier
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Read the data plate on the outdoor unit: 'R-22' or 'HCFC-22' means the old refrigerant; newer units say R-410A, R-454B or R-32.
- The manufacture date is usually on the same plate.
If you find itNothing to do while it works. Budget for replacing the outdoor unit and indoor coil together when it fails.
How commonNo reliable count exists of pre-2010 units still in service.
Keep in mindAir conditioning is often added or replaced long after a house is built, so the unit's age matters far more than the house's.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 5 sources →
Roof & attic1
Factory-built roof trusses
If your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.If your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.
Read the full entry →Built 1955 or later
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- In the attic, look for diagonal 2x4s forming W or M shapes, joined by toothed galvanized steel plates.
- Rafters, by contrast, are larger boards running from the ridge to the wall with open space between.
- Look for cut or notched members and plates that have backed out of the wood.
If you find itNothing is needed unless trusses are damaged or altered. Before any attic conversion, skylight or other change that touches a truss, get an engineer's design.
How commonNo reliable count exists for houses by year built.
Keep in mindTruss use grew over decades, and many houses still use rafters, especially custom homes and complex roofs. A reference source dates the connector plate to 1955.
Details and 1 source →
Exterior walls & windows3
Unreinforced brick (URM) houses
Along Utah's Wasatch Front, many solid-brick houses built before 1975 have no steel reinforcement, and FEMA counts over 185,000 such buildings in the Salt Lake Valley alone.Along Utah's Wasatch Front, many solid-brick houses built before 1975 have no steel reinforcement, and FEMA counts over 185,000 such buildings in the Salt Lake Valley alone.
Read the full entry →Built 1975 or earlier
Federal rule: Dates come from a federal rule or a model building code.PossibleHow to check
- Look at the outside brick walls: rows of bricks laid end-on (header courses) every few rows mean solid brick, not veneer.
- At a window opening, a wall much thicker than a single brick points to solid masonry.
- Star-shaped or square metal plates on the outside wall show past retrofit ties.
- Brick veneer over a wood frame has no header rows and is a different, lesser issue.
If you find itHave a structural engineer assess it, and ask your city whether a local program helps pay for seismic retrofits such as roof-to-wall ties and chimney bracing.
How commonFEMA P-774: over 185,000 unreinforced masonry buildings in the Salt Lake Valley alone, many of them single-family homes.
Keep in mindShown for Utah, where the 1975 date is confirmed. California also has unreinforced brick buildings; seismic code requirements began there in the 1930s.
Details and 5 sources →Asbestos-cement siding and shingles
Hard, thin cement shingles with a wood-grain or dimpled face were a popular siding for much of the 20th century, and many contain asbestos.Hard, thin cement shingles with a wood-grain or dimpled face were a popular siding for much of the 20th century, and many contain asbestos.
Read the full entry →1907–1980
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Look at the siding: hard, thin shingles, often 12 by 24 inches, with a wavy or straight bottom edge and a pressed wood-grain or dimpled surface.
- They crack or chip rather than dent, and show nail heads at the bottom corners.
- Check under later vinyl or aluminum siding, where they are often hidden.
- Some look-alikes were made without asbestos, so only a lab test confirms it.
If you find itKeep them painted and intact. Replace broken pieces with non-asbestos fiber-cement look-alikes, or side over them. Full removal should follow asbestos work rules.
How commonNo reliable count exists. It was one of several competing sidings, and many installs were re-siding jobs on older houses.
Keep in mindNo source gives a firm end year; manufacturers stopped at different times. Many installs were re-siding jobs on older houses, so build year predicts this poorly.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 2 sources →Urea-formaldehyde foam insulation (UFFI)
Some 500,000 homes already had foam insulation pumped into their walls when CPSC banned it in 1982, and a court overturned the ban the next year.Some 500,000 homes already had foam insulation pumped into their walls when CPSC banned it in 1982, and a court overturned the ban the next year.
Read the full entry →Built 1982 or earlier
Court record: Dates come from a court settlement or a product recall.RareHow to check
- Look on the outside walls for rows of patched 1- to 2-inch plugs in siding or mortar joints, where foam was injected.
- In the basement at the sill, or behind an outlet cover on an outside wall (power off first), look for dry, crumbly, off-white to tan foam that powders when touched.
If you find itUsually nothing needs doing. If anyone has symptoms, an indoor air test for formaldehyde is the next step. Removal means opening the walls and is rarely justified on health grounds. Some state disclosure forms ask about UFFI, so keep a note.
How commonA commissioner's statement in CPSC's 1982 release referred to some 500,000 homes already insulated with the foam, a small share of US housing.
Keep in mindIt was installed in new houses and added to existing ones, so build year is a weak guide. The start years are approximate.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 8 sources →
Foundation & basement4
Asbestos pipe and boiler insulation
CPSC says houses built between 1930 and 1950 may have asbestos insulation, often as white wrap on heating pipes and boilers in the basement.CPSC says houses built between 1930 and 1950 may have asbestos insulation, often as white wrap on heating pipes and boilers in the basement.
Read the full entry →Built 1975 or earliermost likely 1930–1950
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- In the basement or crawl space, look for white or gray wrap on pipes that looks like corrugated cardboard in cross-section.
- Look for a hard white plaster-like coating on pipe elbows, boilers and tanks.
- Check duct seams and the edges of registers for white paper or cloth tape.
- Do not touch frayed material; only a lab test confirms asbestos.
If you find itIf it is in good condition, a professional can seal and wrap it. If it is damaged, or before you replace a boiler or finish a basement, have it tested and handled by a licensed abatement contractor.
How commonNo reliable count exists. It depends on whether the house still has an original steam or hot-water system, and much of this insulation has already been removed or sealed.
Keep in mindCPSC lists steam pipes, boilers and furnace ducts wrapped in asbestos blanket or paper tape, but the sources give no clear end date for the duct tape and paper. Many houses of this era have had this insulation removed or sealed.
Details and 4 sources →House not bolted to its foundation
Many older West Coast houses on crawl spaces may not be adequately bolted to their foundations, and in a strong earthquake they can slide off.Many older West Coast houses on crawl spaces may not be adequately bolted to their foundations, and in a strong earthquake they can slide off.
Read the full entry →Built 1979 or earliermost likely up to 1949
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Go into the crawl space and look along the top of the concrete foundation at the wooden sill plate.
- Bolts with nuts and washers along the sill plate mean it is bolted.
- If there is a short wood-stud wall between the foundation and the floor, check whether plywood or OSB is nailed to its inside face.
- Houses on a concrete slab have no cripple wall.
If you find itA contractor can bolt the sill and brace the cripple walls with plywood. Ask your city or county whether it publishes retrofit plans or has a program that helps pay for the work.
How commonNo reliable count exists. Only houses on raised foundations with crawl spaces are affected; slab houses are not.
Keep in mindThere is no single code year: a reference source says many structures built before 1950 may not be adequately bolted, and the 1979 end used here is an unconfirmed program screen, not a code date. Many houses have already been retrofitted.
Details and 2 sources →Chlordane termite treatment
From 1948 to 1988, chlordane was used in the US as a pesticide, including against termites around houses, and ATSDR says more than 50 million people have lived in treated homes.From 1948 to 1988, chlordane was used in the US as a pesticide, including against termites around houses, and ATSDR says more than 50 million people have lived in treated homes.
Read the full entry →1948–1988
Federal rule: Dates come from a federal rule or a model building code.PossibleHow to check
- There is no visible sign. Look for old termite-treatment records or pest-control stickers.
- Look for patched drill holes in the slab, garage floor or along the foundation walls.
- Only an indoor air or soil lab test confirms it.
If you find itIf you are concerned, test the indoor air. Seal slab cracks and crawl-space and duct leaks, ventilate basements and crawl spaces, and avoid growing food crops right beside the foundation.
How commonATSDR: over 50 million people have lived in chlordane-treated homes; Wikipedia puts it at about 30 million homes. Use was heaviest in the deep South and Southwest.
Keep in mindTreatment was done both during construction and later on existing houses, so any house standing before 1988 in termite country may have been treated. Many houses never were.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 9 sources →Engineered I-joist floors
By 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.By 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.
Read the full entry →Built 1970 or latermost likely from 2000
Approximate era: Dates are an approximate era drawn from trade and reference sources.PossibleHow to check
- Look up at the basement or garage ceiling for I-shaped joists: a thin OSB or plywood web with small lumber flanges top and bottom.
- They are usually printed with the maker's brand name.
- If you can see them, they are unprotected from below.
If you find itConsider covering exposed I-joists with drywall, and make sure working smoke alarms cover every level, including the basement.
How commonWikipedia: about 50% of wood light-frame floors used I-joists as of 2005.
Keep in mindNewer model codes are reported to require covering them, but that was not confirmed and code adoption varies by state. The hazard applies only where the joists are exposed.
Details and 2 sources →
Garage, deck & yard2
Arsenic-treated (CCA) deck lumber
Pressure-treated wood in decks and play sets built before 2004 was commonly treated with an arsenic compound, and EPA says never to burn it.Pressure-treated wood in decks and play sets built before 2004 was commonly treated with an arsenic compound, and EPA says never to burn it.
Read the full entry →1975–2004most likely 1980–2003
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Look at decks, play sets, fences and garden edging built of pressure-treated wood before 2004.
- End tags or ink stamps may read 'CCA' with a number such as 0.40; newer wood reads ACQ, CA or MCA.
- Arsenic swab test kits and lab tests exist.
If you find itWash hands after contact, never burn the wood or use it for garden beds, and wear a mask when cutting it. Sealants may reduce surface arsenic, but CPSC testing found few held up after two years. Replace with alternative-treated wood or composite when the deck is due.
How commonNo reliable count exists. EPA says CCA-treated wood was used in decks and playsets before 2004, but no market-share figure was found.
Keep in mindAt manufacturers' request, EPA cancelled CCA for most residential wood, including decks, after December 30, 2003, but old stock could still be sold, so some decks built in 2004 may have used it. The 1975 start is approximate. Decks are often built or replaced long after the house, so the deck's age matters more than the house's.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 10 sources →PCBs in old fluorescent light ballasts
Fluorescent light ballasts made before July 2, 1979 may contain PCBs, and EPA required PCB-free ballasts made from July 1978 to July 1998 to be marked 'No PCBs'.Fluorescent light ballasts made before July 2, 1979 may contain PCBs, and EPA required PCB-free ballasts made from July 1978 to July 1998 to be marked 'No PCBs'.
Read the full entry →1950–1979
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Turn the power off, open the fluorescent fixture cover and read the ballast label.
- A 'No PCBs' label means the ballast is PCB-free. EPA required that label on PCB-free ballasts made from July 1978 to July 1998, so a later ballast may have no label at all.
- An unlabeled magnetic ballast, or oily or tarry leakage, suggests a PCB ballast. Only magnetic T12 ballasts may contain PCBs.
If you find itReplace the old fixture or ballast, and take a PCB ballast to a hazardous-waste collection rather than the trash. Before renovating a 1950 to 1979 masonry apartment building, have suspect caulk tested.
How commonNo reliable count exists for houses; EPA's material is about schools and other larger buildings.
Keep in mindEPA's guidance addresses schools and other buildings, not single-family homes.
Details and 4 sources →
What’s due at this age
A 1975 house is 51 years old. Here is where its parts stand against their typical life, and which ones have certainly been replaced by now.
- In their window
- 4
- Past life, if original
- 5
- Due within 5 yrs
- 0
- Replaced by now
- 36
36 of the 53 parts we track wear out so much faster than a 1975 house has stood that they have been replaced at least once. Know when something was last replaced? Enter the year (or a decade, like 2010s) and we’ll show where that part stands. It stays on this device only.
First life ending around now
4Long-lived parts installed in 1975 reach the end of their typical life about now. If they are original, these are the ones to look at and budget for.
- Cast-iron drain pipe (below ground)Drains & sewer · lasts 50–60 yrs
Old cast-iron drains rust from the inside. Repeated backups and slow drains in a house of this age are worth a camera inspection.
50–60 yrsIn its windowif original - Copper water supply linesWater pipes · lasts 50–70 yrs
Acidic water and high pressure shorten life. Green stains and pinhole leaks are the warning signs.
50–70 yrsIn its windowif original - Metal roofRoof · lasts 40–80 yrs
Life depends on the metal and coating. Loose fasteners and flashing are usually what fail first, not the panels.
40–80 yrsIn its windowif original - Chimney flue tileChimney · lasts 40–120 yrs
CPSC says a fireplace can start a fire if the chimney is cracked, blocked or coated with creosote. It advises a professional inspection of chimneys, flues and vents every year, so have one done before using the fireplace in an older house.
40–120 yrsIn its windowif original
Past typical life, if still original
5Older than the usual range, but not so old that an original is unlikely. Worth finding out whether they have been replaced.
- Concrete walkwayDeck & yard · lasts 40–50 yrs40–50 yrs1 yr pastif original
- Aluminum gutters and downspoutsRoof · lasts 20–40 yrs20–40 yrs11 yrs pastif original
- Boiler (hot-water or steam)Heating & cooling · lasts ~40 yrs~40 yrs11 yrs pastif original
- Septic systemDrains & sewer · lasts 15–40 yrs15–40 yrs11 yrs pastif original
- Vinyl or fiberglass windowsWindows · lasts 20–40 yrs20–40 yrs11 yrs pastif original
Replaced at least once by now: find out when36
A 1975 house has outlasted these parts’ typical life several times over, so what matters is when each was last replaced. Ask the seller or check receipts and date labels; enter a year and the part moves up to where it stands.
- Carbon monoxide alarmWhole houselasts ~5 yrs≈10 lifetimes
- Dryer vent (plastic)Whole houselasts ~5 yrs≈10 lifetimes
- Sump pumpBasement & foundationlasts ~7 yrs≈7 lifetimes
- DishwasherKitchenlasts ~9 yrs≈5 lifetimes
- CarpetWalls, ceilings & floorslasts 8–10 yrs≈5 lifetimes
- Caulking (interior and exterior)Exterior wallslasts 5–10 yrs≈6 lifetimes
- Exterior paintExterior wallslasts 7–10 yrs≈6 lifetimes
- Smoke alarmWhole houselasts ~10 yrs≈5 lifetimes
- Garbage disposalKitchenlasts ~12 yrs≈4 lifetimes
- Clothes dryerWhole houselasts ~13 yrs≈3 lifetimes
- RefrigeratorKitchenlasts 9–13 yrs≈4 lifetimes
- Central air conditionerHeating & coolinglasts 7–15 yrs≈4 lifetimes
- Electric rangeKitchenlasts 13–15 yrs≈3 lifetimes
- Garage door openerGaragelasts 10–15 yrs≈4 lifetimes
- Heat pumpHeating & coolinglasts 10–15 yrs≈4 lifetimes
- Tank water heaterWater heaterlasts 6–15 yrs≈4 lifetimes
- Washing machineBathroomlasts 5–15 yrs≈5 lifetimes
- Well pumpWater pipeslasts ~15 yrs≈3 lifetimes
- Wood deck boardsDeck & yardlasts ~15 yrs≈3 lifetimes
- Gas rangeKitchenlasts 15–17 yrs≈3 lifetimes
- Aluminum windowsWindowslasts 15–20 yrs≈2 lifetimes
- Asphalt drivewayDeck & yardlasts 15–20 yrs≈2 lifetimes
- Asphalt shingle roof (3-tab)Rooflasts ~20 yrs≈2 lifetimes
- Faucets and spray hoseBathroomlasts 15–20 yrs≈2 lifetimes
- Flat roof (modified bitumen)Rooflasts ~20 yrs≈2 lifetimes
- Tankless water heaterWater heaterlasts 10–20 yrs≈3 lifetimes
- Water softenerWater pipeslasts ~20 yrs≈2 lifetimes
- Flat roof (EPDM rubber)Rooflasts 15–25 yrs≈2 lifetimes
- Forced-air furnaceHeating & coolinglasts 15–25 yrs≈2 lifetimes
- Garage doorGaragelasts 20–25 yrs≈2 lifetimes
- Vinyl floorWalls, ceilings & floorslasts ~25 yrs≈2 lifetimes
- Wood shake roofRooflasts ~25 yrs≈2 lifetimes
- Asphalt shingle roof (architectural)Rooflasts ~30 yrs≈1 lifetimes
- Deck framingDeck & yardlasts 10–30 yrs≈2 lifetimes
- GFCI outletsKitchenlasts ~30 yrs≈1 lifetimes
- Wood windowsWindowslasts ~30 yrs≈1 lifetimes
Further out8
- Electrical service panelElectrical panellasts ~60 yrsin 9 yrs
- Heating and cooling ductworkHeating & coolinglasts 60–100 yrsin 9 yrs
- Vinyl sidingExterior wallslasts ~60 yrsin 9 yrs
- Clay or concrete tile roofRooflasts ~100 yrsin 49 yrs
- Fiber cement sidingExterior wallslasts ~100 yrsin 49 yrs
- Fiberglass exterior doorWhole houselasts ~100 yrsin 49 yrs
- Hardwood floorWalls, ceilings & floorslasts ~100 yrsin 49 yrs
- ToiletsBathroomlasts ~100 yrsin 49 yrs
Typical lives from InterNACHI Standard Estimated Life Expectancy Chart for Homes, CPSC, U.S. Department of Energy (hosted guide), US Department of Energy, Energy Saver Guide (2022), InterNACHI, Smoke Alarm Inspection, US EPA, New Homebuyer's Guide to Septic Systems, InterNACHI and U.S. Consumer Product Safety Commission. Real lives vary with climate, quality and upkeep.
Your place
Add a ZIP code for a few sourced facts about where the house stands: the homes around it, radon, climate and flood maps. All optional.
Looking up a ZIP code needs JavaScript. Everything else on this page works without it.
Part two
The year in context
What was changing around 1975, how much the country was building, how houses of this era stand today and what homes were like then. All of it describes houses in general, never this one.
The year in context · events
Around 1975: what was changing in homebuilding
What happened in 1975 first, then the nearest dated events within 1 year either side, then longer changes 1975 falls inside. Each comes with its source and how strong that source is.
In 1975
- 1975circa
Codes
Energy conservation standards enter residential codes
In this report’s record of issues: Built before energy codes
- 1975
Electrical
GFCI protection required in bathrooms
In this report’s record of issues: Missing GFCI shock protection
U.S. Consumer Product Safety CommissionPrimary source
Nearby, 1974 to 1976within 1 year of 1975
- 1974
Electrical
CPSC issues first aluminum wiring recommendations
In this report’s record of issues: Aluminum branch wiring
U.S. Consumer Product Safety CommissionPrimary source - 1974
Policy
National manufactured housing act passed
The National Manufactured Housing Construction and Safety Standards Act of 1974 gave HUD authority to set a national standard for factory-built homes, replacing a patchwork of state rules.
WikipediaReferenceQuote
“In the United States, mobile homes are regulated by the US Department of Housing and Urban Development (HUD), via the Federal National Manufactured Housing Construction and Safety Standards Act of 1974.” Wikipedia
- 1976
Policy
HUD manufactured home code takes effect
In this report’s record of issues: Mobile home built before the HUD Code
WikipediaReference - 1976
Policy
Weatherization Assistance Program created
Congress created the Weatherization Assistance Program in 1976, in response to the 1973 oil crisis, to insulate and air-seal the homes of low-income families. Older houses may have been retrofitted with insulation under it.
U.S. Department of EnergyPrimary sourceQuote
“The program was created in 1976 under Title IV of the Energy Conservation and Production Act” U.S. Department of Energy
Under way in 1975long-running
- 1973–1978
Materials
Cellulose insulation boom after the oil embargo
Demand for insulation rose after the 1973-74 oil embargo, and loose-fill cellulose was made by hundreds of small firms. The federal government began enacting insulation standards in 1978 over safety and quality concerns.
WikipediaReferenceQuotes
“Demand for insulation increased following the oil embargo of 1973–74” Wikipedia
“the U.S. federal government began enacting insulation standards beginning in 1978” Wikipedia
- 1970–1979circa
Materials
Waferboard and particleboard panels developed
InterNACHI says waferboard and particleboard panels were developed in the 1970s for use alongside plywood, which is why panel sheathing from the 1970s and 1980s may not be plywood.
InterNACHITrade referenceQuote
“Waferboard or particle board was developed in the 1970s” InterNACHI
Events come from a researched timeline of 150 dated changes to US homebuilding, each checked against the quoted source. Primary source is a government or standards body, Trade reference a trade body and Reference a general reference such as Wikipedia. A date is when something began or became required, not when every builder followed.
The year in context · building
Housing that year
How many new homes were started across the US in 1975, against every year since 1889. It is the whole country’s building, houses and apartments, not a count of houses like this one.
New homes started · 1975 · US
About 1.16 million new homes (houses and apartments) were started in 1975, the fewest since 1946, and 13% fewer than in 1974.
- Started
- 1.16 million
- Median new house price
- $39,3001975 $
- In one-family buildings
- 77%
- Before 1959 the counts are historical estimates: Historical Statistics of the United States reconstructed them from building permits and other records, in series that change method in 1920, 1930 and 1945. They leave out farm housing. The figures here were transcribed by hand from a scanned copy and checked against the table’s own totals.
- From 1959 the count is the Census Bureau’s privately owned housing units started; public housing is not in it. Mobile homes, conversions and temporary units are never counted.
- The median new house price is in the dollars of 1975, not adjusted for inflation.
Source US Census Bureau, Historical Statistics of the United States, Colonial Times to 1970, Series N 156 (1889–1958); New Residential Construction, annual housing starts (1959–2025); New Residential Sales, median sales price of new houses sold.
As built · new houses of 1975
The typical new house of 1975
How new single-family houses completed in 1975 across the US were built, from the US Census Bureau’s Survey of Construction. These describe that year’s new houses, not this one, and a house may have been altered since.
Showing the whole US · choose your state above, or a region here
New houses · 1975 · US
Most often: one story, with a basement, wood outside, electric heat and no air-conditioning.
- Median size
- 1,535sq ft
- Completed
- 875,000houses
Median size, sq ft
Floors
65% 1 story
- 1 story65%
- 2 or more23%
- Split-level12%
- Floors are counted two ways: through 2008, 1 story, 2 or more, and split-level; from 2009, split-level and 1½-story houses count as 2 stories and 3 or more is separate. Only “1 story” is roughly comparable across the change.
1 story, over time
Foundation
45% Full or partial basement
- Basement45%
- Slab or other35%
- Crawl space20%
- The Census counts slabs together with other foundations such as piers and pilings, so this is “slab or other”, never slab alone.
Full or partial basement, over time
Outside walls
36% Wood
- Brick32%
- Wood36%
- Stucco10%
- Other, incl. vinyl22%
- Vinyl siding was not counted separately until 1992. Before then it sits inside “other”, with aluminum, block and stone.
- Fiber cement was not counted separately until 2005. Before then it sits inside “other”.
Wood, over time
Heating fuel
49% Electricity
- Gas40%
- Electricity49%
- Oil9%
- Other or none2%
- Gas includes bottled gas and propane as well as natural gas.
Electricity, over time
Heating system
72% Forced-air furnace
- Forced-air furnace72%
- Hot water or steam6%
- Other or none21%
- Heat pumps were not counted separately until 1978.
Forced-air furnace, over time
Air-conditioning
54% Without
- With air-conditioning46%
- Without54%
Without, over time
Bedrooms
65% 3 bedrooms
- 2 or fewer14%
- 365%
- 4 or more21%
3 bedrooms, over time
Bathrooms
41% 1½ bathrooms or fewer
- 1½ or fewer41%
- 240%
- 2½ or more20%
- Through 1986, “2½” includes 2½ bathrooms or more.
1½ bathrooms or fewer, over time
Garage
53% Garage for 2 or more cars
- 1-car garage14%
- 2+ car garage53%
- Carport9%
- None24%
- Garages for 3 or more cars were counted with 2-car garages until 1992.
Garage for 2 or more cars, over time
Fireplaces
48% No fireplace
- None48%
- 146%
- 2 or more6%
No fireplace, over time
- These are new single-family houses completed that year in that region, including houses built for rent. They describe how houses were being built, not any one house.
- Counts before 1999 include a 3.3 percent upward adjustment for houses built without permits in areas that issue permits, so house counts before and after 1999 are not strictly comparable.
- These are survey estimates. Sampling error is larger for older years, for single regions and for small categories; “withheld” marks cells the Census did not publish.
- Roofing is not recorded by this survey. Houses were not counted by state, so a region is the closest view.
Source US Census Bureau, Survey of Construction (Characteristics of New Housing), houses completed. Tables: Stories (2008 report), Foundation, Exterior Wall Material, Heating Fuel, Heating System, Air-Conditioning, Bedrooms, Bathrooms, Parking Facility, Fireplaces, Square feet.
As they stand today · houses built in the 1970s
Houses of the 1970s, today
The typical new house above is how houses were built in 1975. This is the other view: houses built in the 1970s that are still standing and lived in, as they are now, after decades of new roofs, new siding and renovation. Not as they were built.
Showing the whole US · detached single-family houses
Roofs today · built in the 1970s · US
About 4 in 5 surviving houses from the 1970s across the US have asphalt shingle roofs today, and about 1 in 12 has a metal roof.
Roof material as reported in 2020. Most roofs have been replaced at least once since these houses were built, so this is what is on them now.
- Homes sampled
- 1,780
- Average size
- 2,149sq ft
- Asphalt shingles82%
- Metal8%
- Wood shakes4%
- Slate1%
- Clay tile3%
- Concrete tile2%
- Other1%
1,780 homes sampled · EIA RECS 2020
Asphalt shingles, by era built
The shell
Outside walls
36% Siding: vinyl, aluminum, fiber cement or steel
- Siding36%
- Brick28%
- Wood18%
- Stucco11%
- Stone1%
- Concrete block4%
- Other2%
1,780 homes sampled · EIA RECS 2020
Siding, by era built
Window glass
69% Double-pane
- Single-pane30%
- Double-pane69%
- Triple-pane2%
1,780 homes sampled · EIA RECS 2020
Double-pane, by era built
Foundation
38% Slab
- Full basement26%
- Part basement12%
- Crawl space23%
- Slab38%
- Other1%
3,974 homes sampled · AHS 2023
Slab, by era built
Stories
66% 1 story
- 1 story66%
- 2 stories25%
- 3 or more2%
- Split-level6%
1,780 homes sampled · EIA RECS 2020
1 story, by era built
Heating and cooling
Main heating fuel
44% Piped gas
- Gas44%
- Electricity42%
- Oil5%
- Propane6%
- Wood3%
- Other1%
3,974 homes sampled · AHS 2023
Piped gas, by era built
Main heating equipment
70% Forced warm-air furnace
- Furnace70%
- Boiler6%
- Heat pump13%
- Electric baseboard4%
- Wall or room heater4%
- Stove or fireplace2%
- Other or none2%
3,974 homes sampled · AHS 2023
Forced warm-air furnace, by era built
Air-conditioning
79% Central air
- Central air79%
- Room units only12%
- None8%
3,974 homes sampled · AHS 2023
Central air, by era built
The rooms
Bathrooms
41% Two full bathrooms
- No full bath<0.5%
- 116%
- 1½14%
- 241%
- 2½14%
- 3+15%
3,974 homes sampled · AHS 2023
Two full bathrooms, by era built
Fireplace
50% Usable fireplace
- Usable fireplace50%
- None50%
3,974 homes sampled · AHS 2023
No usable fireplace, by era built
Size
29% 1,500 to 1,999 sq ft
- Under 1,0006%
- 1,000–1,49925%
- 1,500–1,99929%
- 2,000–2,49920%
- 2,500+19%
3,729 homes sampled · AHS 2023
1,500 to 1,999 sq ft, by era built
Garage or carport
84% Garage or carport
- Garage or carport84%
- Neither16%
3,965 homes sampled · AHS 2023
Garage or carport, by era built
- Surviving detached single-family houses as they are today, by the decade their occupants say they were built. Roofs, siding, windows and heating include every replacement since. Houses that were torn down are not in it, so this is not how the era built.
- In the Census Bureau’s words, “some of the home characteristics … may have been more recent additions or installations and did not come with the home when it was originally built.”
- Survey estimates from samples of homes: a band with fewer than 30 sampled homes is never shown, and one with fewer than 100 is marked small sample. The EIA survey covers occupied primary homes only; the American Housing Survey also counts vacant ones.
Source US Energy Information Administration, Residential Energy Consumption Survey 2020, public microdata (roof, walls, window glass, stories, size); US Census Bureau and HUD, American Housing Survey 2023, national public use file (everything else); shares computed from the public microdata with the surveys’ weights. Caveat quoted from Census working paper 2011-18.
The year in context · the country
The country in 1980
From the 1980 census, the one nearest 1975. These describe every home standing at the time, old and new, not houses built that year.
| Fact | US |
|---|---|
| Lacking complete plumbinghot and cold piped water, a bathtub or shower, and a flush toiletCensus, plumbing | 2.7% |
| Main house heating fuelsoccupied homesCensus, house heating fuel | utility gas 53.1%electricity 18.4%oil or kerosene 18.2%bottled gas 5.6% |
| On a public sewerseptic tank or cesspool: 24.1% across the USCensus, sewage disposal | 74.0% |
| Water from a public system or companyown well: 15.1% across the USCensus, source of water | 83.6% |
| Homes owned by the people living in themCensus, homeownership | 64.4% |
| Homes built in the 1970s still standing todayACS 2020-2024, B25034 | 20.4 million 14.2% of homes |
| Half of all homes standing today were built beforethe median year builtACS 2020-2024, B25035 | 1980 |
Census figures are shares of homes counted in 1980 (year-round homes for sewer and water). Until 1990 plumbing counted as complete only when the household had it to itself. Today’s count is the US Census Bureau’s American Community Survey, 2020 to 2024, which includes vacant homes and dates them by what residents report. Choose your state above to see it beside the US.
See something in the 1975 report that looks wrong?Report an error on this page