Year Built

Built without · Electrical

Outlets without child-safety shutters

Since the 2008 electrical code, new houses get outlets with built-in shutters that stop a child pushing a key or hairpin into the slot.

Houses built without it
2010 or earlier
Dates from
Federal rule: Dates come from a federal rule or a model building code.
How common
No reliable count exists
Priority
Good to know
Mainly about
Safety
Where to look
Wiring & outlets

What it is

Tamper-resistant outlets have spring-loaded shutters that open only when both prongs of a plug push in together. They were first required by the 2008 National Electrical Code, and by 2016 that applied to new houses in all but five states. A figure cited by the electrical manufacturers' association and InterNACHI is about 2,400 children a year hurt by pushing objects into outlets.

How sure the dates are

Federal rule: Dates come from a federal rule or a model building code.

Dates come from a federal rule or a model building code. What the labels mean

How common it is

No reliable count exists

Houses built before their state adopted the 2008 code will generally lack them unless outlets were replaced.

The years

Houses built in 2010 or earlier were built without it, unless it has been added since. The gap is most common in houses built 2007 or earlier.

Earliest
Before 1880No start date. It reaches back past 1880, where these records begin.
Most likely
To 2007The years when houses most often went without it.
Latest
About 2010An approximate date. Places adopted the requirement at different times.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

How to check

  1. Look closely at an outlet: 'TR' embossed on the face between the slots means tamper-resistant.

  2. You can see plastic shutters inside the slots.

Where to look
  • Wiring & outlets

What to do

If it was never addedIf small children live in or visit the house, have outlets replaced with TR-listed ones.

Sources

3 verified sources, 1 primary. Each quote is copied word for word from the page linked.

  1. HUD Manufactured Housing Consensus Committee, draft meeting minutes October 2016 (the statement is in a NEMA comment letter reproduced in the minutes, not a HUD finding)Primary source

    TRRs have been required since the 2008 edition of the NEC, which means that they are required for new homes in all but five states.

    hud.gov/sites/documents/mhcc-oct2016-meetminsdraft.pdf (opens in a new tab)
  2. InterNACHITrade reference

    approximately 2,400 children suffer from electrical shock and burns in the home each year when they force foreign objects into unprotected electrical outlets

    nachi.org/tamper-resistant-receptacles.htm (opens in a new tab)
  3. WikipediaReference

    Starting with the 2008 National Electrical Code

    en.wikipedia.org/wiki/NEMA_connector (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Reports for houses built without it

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.