Aluminum branch wiring

From 1965 to the mid-1970s, some houses were wired with solid aluminum instead of copper, and CPSC reports that pre-1972 aluminum-wired homes were 55 times more likely to have one or more outlet connections reach fire-hazard conditions.

Houses built
1965–1975
Dates from
Approximate era: Dates are an approximate era drawn from trade and reference sources.
How common
Possible
Priority
Check first
Mainly about
Safety
Where to look
Wiring & outlets · Electrical panel · Attic · Basement & foundation

What it is

Single-strand aluminum wire was used for ordinary outlet and light circuits in an estimated two million homes and mobile homes built from 1965 on, according to CPSC. The risk is at the connections, at outlets, switches and splices, which can loosen and overheat. CPSC recognizes specific permanent repairs.

How sure the dates are

Approximate era: Dates are an approximate era drawn from trade and reference sources.

Dates are an approximate era drawn from trade and reference sources. What the labels mean

How common it is

Possible

CPSC estimated in 1974 that about two million homes and mobile homes had been built with aluminum wiring since 1965. No figure gives the share of houses of the era.

The years

Houses built from 1965 to 1975 may have it. It is most likely in houses built 1965 to 1972.

Earliest
About 1965An approximate date. It came in gradually, and sources differ by a few years.
Most likely
1965–1972The years it is most common: the solid part of the band.
Latest
About 1975An approximate date. The change came gradually, so a few later houses may have it.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

How to check

  1. Look at any exposed cable in the attic, basement or near the panel for 'AL' or 'ALUMINUM' printed on the plastic jacket every few feet.

  2. Cable marked 'CU-clad' or 'copper-clad' uses copper-coated aluminum wire and is not covered by CPSC's aluminum repair advice; ask an electrician about it.

  3. Warning signs: cover plates that feel warm, flickering lights, or a smell of burning plastic at an outlet.

  4. Do not open outlet or switch boxes yourself.

Where to look
  • Wiring & outlets
  • Electrical panel
  • Attic
  • Basement & foundation

What to do

If you find itCall a licensed electrician who uses one of the three permanent repairs CPSC approves: rewiring with copper, COPALUM crimp connectors, or AlumiConn connectors. CPSC calls CO/ALR outlets and switches at best an incomplete repair, and says twist-on pigtail connectors do not solve the overheating problem. If you notice warm plates or a burning smell, stop using that circuit until it is checked.

Sources

12 verified sources, 11 primary. Each quote is copied word for word from the page linked.

  1. US CPSC, Publication 516 'Repairing Aluminum Wiring' (June 2011)Primary source

    homes built before 1972, and wired with aluminum, are 55 times more likely to have one or more wire connections at outlets reach “Fire Hazard Conditions”

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  2. US CPSC news release, 1974Primary source

    An estimated two million homes and mobile homes have been constructed using aluminum wiring since 1965.

    cpsc.gov/Newsroom/News-Releases/1974/CPSC-Safety-Reco… (opens in a new tab)
  3. U.S. Consumer Product Safety CommissionPrimary source

    CPSC approves of only three methods for a permanent repair.

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  4. U.S. Consumer Product Safety CommissionPrimary source

    if the COPALUM repair is not available, the AlumiConn connector may be considered the next best alternative for a permanent repair.

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  5. U.S. Consumer Product Safety CommissionPrimary source

    CO/ALR devices must be considered, at best, an incomplete repair.

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  6. U.S. Consumer Product Safety CommissionPrimary source

    CPSC staff believes that this method of repair does not solve the problem of overheating present in aluminum-wired branch circuits.

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  7. U.S. Consumer Product Safety CommissionPrimary source

    CO/ALR devices may be used as an emergency, temporary repair

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  8. U.S. Consumer Product Safety CommissionPrimary source

    No information was developed for aluminum-wired homes built after 1972.

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  9. U.S. Consumer Product Safety CommissionPrimary source

    Homes built before 1965 are unlikely to have aluminum branch circuit wiring.

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  10. U.S. Consumer Product Safety CommissionPrimary source

    Electrical cables installed between 1965 and the mid 1970s in new homes, in additions, and as part of rewired/new circuits may contain aluminum wiring.

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  11. U.S. Consumer Product Safety CommissionPrimary source

    means that the cable uses copper-coated aluminum wire and is not covered by the repair recommendations outlined in this publication

    cpsc.gov/s3fs-public/516.pdf (opens in a new tab)
  12. InterNACHITrade reference

    Between approximately 1965 and 1973, single-strand (solid) aluminum wiring was sometimes substituted for copper branch-circuit wiring in residential electrical systems

    nachi.org/aluminum-wiring.htm (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Applies to houses built

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.