Check firstOften present · Electrical
Aluminum branch wiring
From 1965 to the mid-1970s, some houses were wired with solid aluminum instead of copper, and CPSC reports that pre-1972 aluminum-wired homes were 55 times more likely to have one or more outlet connections reach fire-hazard conditions.
- Houses built
- 1965–1975
- Dates from
- Approximate era: Dates are an approximate era drawn from trade and reference sources.
- How common
- Possible
- Priority
- Check first
- Mainly about
- Safety
- Where to look
- Wiring & outlets · Electrical panel · Attic · Basement & foundation
What it is
Single-strand aluminum wire was used for ordinary outlet and light circuits in an estimated two million homes and mobile homes built from 1965 on, according to CPSC. The risk is at the connections, at outlets, switches and splices, which can loosen and overheat. CPSC recognizes specific permanent repairs.
How sure the dates are
Approximate era: Dates are an approximate era drawn from trade and reference sources.Dates are an approximate era drawn from trade and reference sources. What the labels mean
How common it is
PossibleCPSC estimated in 1974 that about two million homes and mobile homes had been built with aluminum wiring since 1965. No figure gives the share of houses of the era.
The years
Houses built from 1965 to 1975 may have it. It is most likely in houses built 1965 to 1972.
- Earliest
- About 1965An approximate date. It came in gradually, and sources differ by a few years.
- Most likely
- 1965–1972The years it is most common: the solid part of the band.
- Latest
- About 1975An approximate date. The change came gradually, so a few later houses may have it.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
How to check
Look at any exposed cable in the attic, basement or near the panel for 'AL' or 'ALUMINUM' printed on the plastic jacket every few feet.
Cable marked 'CU-clad' or 'copper-clad' uses copper-coated aluminum wire and is not covered by CPSC's aluminum repair advice; ask an electrician about it.
Warning signs: cover plates that feel warm, flickering lights, or a smell of burning plastic at an outlet.
Do not open outlet or switch boxes yourself.
- Wiring & outlets
- Electrical panel
- Attic
- Basement & foundation
What to do
If you find itCall a licensed electrician who uses one of the three permanent repairs CPSC approves: rewiring with copper, COPALUM crimp connectors, or AlumiConn connectors. CPSC calls CO/ALR outlets and switches at best an incomplete repair, and says twist-on pigtail connectors do not solve the overheating problem. If you notice warm plates or a burning smell, stop using that circuit until it is checked.
Sources
12 verified sources, 11 primary. Each quote is copied word for word from the page linked.
US CPSC, Publication 516 'Repairing Aluminum Wiring' (June 2011)Primary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)homes built before 1972, and wired with aluminum, are 55 times more likely to have one or more wire connections at outlets reach “Fire Hazard Conditions”
US CPSC news release, 1974Primary source
cpsc.gov/Newsroom/News-Releases/1974/CPSC-Safety-Reco… (opens in a new tab)An estimated two million homes and mobile homes have been constructed using aluminum wiring since 1965.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)CPSC approves of only three methods for a permanent repair.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)if the COPALUM repair is not available, the AlumiConn connector may be considered the next best alternative for a permanent repair.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)CO/ALR devices must be considered, at best, an incomplete repair.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)CPSC staff believes that this method of repair does not solve the problem of overheating present in aluminum-wired branch circuits.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)CO/ALR devices may be used as an emergency, temporary repair
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)No information was developed for aluminum-wired homes built after 1972.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)Homes built before 1965 are unlikely to have aluminum branch circuit wiring.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)Electrical cables installed between 1965 and the mid 1970s in new homes, in additions, and as part of rewired/new circuits may contain aluminum wiring.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/s3fs-public/516.pdf (opens in a new tab)means that the cable uses copper-coated aluminum wire and is not covered by the repair recommendations outlined in this publication
InterNACHITrade reference
nachi.org/aluminum-wiring.htm (opens in a new tab)Between approximately 1965 and 1973, single-strand (solid) aluminum wiring was sometimes substituted for copper branch-circuit wiring in residential electrical systems
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.