Often present · Electrical

Two-prong outlets with no ground

Outlets with only two slots were normal until 1962, when grounded outlets became required in new houses.

Houses built
1966 or earlier
Dates from
Approximate era: Dates are an approximate era drawn from trade and reference sources.
How common
No reliable count exists
Priority
Worth a look
Mainly about
Safety
Where to look
Wiring & outlets · Electrical panel

What it is

Before the early 1960s, house circuits usually had two wires and no ground. Three-prong appliances and surge protectors rely on a ground, and plug adapters defeat that protection. One reference source dates the rule for every new outlet later still, to January 1, 1974.

How sure the dates are

Approximate era: Dates are an approximate era drawn from trade and reference sources.

Dates are an approximate era drawn from trade and reference sources. What the labels mean

How common it is

No reliable count exists

Before 1962 the code did not require grounded outlets, so a house of that age started with mostly two-wire circuits; how many have been rewired is unknown.

The years

Houses built in 1966 or earlier may have it. It is most likely in houses built 1961 or earlier.

Earliest
Before 1880No start date. It reaches back past 1880, where these records begin.
Most likely
To 1961The years it is most common: the solid part of the band.
Latest
About 1966An approximate date. The change came gradually, so a few later houses may have it.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

How to check

  1. Look at the outlets: two slots and no round ground hole means an ungrounded outlet.

  2. Where an older house has three-prong outlets, a plug-in outlet tester from a hardware store will show 'open ground' if no ground is connected.

  3. If an electrician opens the panel, old cables with only two conductors and no bare ground wire are another sign. Do not remove the panel cover yourself.

Where to look
  • Wiring & outlets
  • Electrical panel

What to do

If you find itAn electrician can run new grounded circuits, or protect ungrounded outlets with GFCI devices labeled 'No Equipment Ground', an accepted fix according to InterNACHI. A GFCI gives shock protection but is not a true ground.

Sources

2 verified sources. Each quote is copied word for word from the page linked.

  1. InterNACHITrade reference

    an important safety feature that has been required in new construction since 1962

    nachi.org/ungrounded-electrical-receptacles.htm (opens in a new tab)
  2. WikipediaReference

    1-15R receptacles have been prohibited in new construction in the United States and Canada since 1962, but remain in many older buildings

    en.wikipedia.org/wiki/NEMA_connector (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Applies to houses built

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.