Cloth-covered rubber-insulated wiring
Between knob-and-tube and modern plastic cable, many houses were wired with rubber-insulated wire in a woven cloth jacket, and that old rubber can get brittle.
- Houses built
- 1925–1965
- Dates from
- Approximate era: Dates are an approximate era drawn from trade and reference sources.
- How common
- No reliable count exists
- Priority
- Worth a look
- Mainly about
- Safety
- Where to look
- Wiring & outlets · Electrical panel · Basement & foundation · Attic
What it is
Nonmetallic sheathed cable was invented in 1922 and first listed in the National Electrical Code in 1926. For decades after, wiring commonly used rubber-insulated conductors inside a cloth or steel-armored jacket. Old rubber insulation can dry out and flake, especially at hot ceiling light boxes, and older cable often has no ground wire.
How sure the dates are
Approximate era: Dates are an approximate era drawn from trade and reference sources.Dates are an approximate era drawn from trade and reference sources. What the labels mean
How common it is
No reliable count existsFor a house built from about 1930 to 1955 that was never rewired, this was probably the normal wiring method, but that is an informed guess, not a measured figure.
The years
Houses built from 1925 to 1965 may have it. It is most likely in houses built 1930 to 1955.
- Earliest
- About 1925An approximate date. It came in gradually, and sources differ by a few years.
- Most likely
- 1930–1955The years it is most common: the solid part of the band.
- Latest
- About 1965An approximate date. The change came gradually, so a few later houses may have it.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
How to check
At the panel, in the basement or in the attic, look for cables with a braided fabric outer covering (black, silver or brown, sometimes tarry) instead of smooth plastic.
Inside boxes, the individual wires have cloth over black or red rubber that cracks or flakes. Ceiling light boxes, where heat damage is worst, are the place for an electrician to look first.
Do not bend or flex old wires to test them.
- Wiring & outlets
- Electrical panel
- Basement & foundation
- Attic
What to do
If you find itHave an electrician check the lighting circuits and any brittle runs. Replacing the worst runs, or rewiring, is the usual fix; GFCI or AFCI protection can be added in the meantime.
Sources
1 verified source. Each quote is copied word for word from the page linked.
WikipediaReference
en.wikipedia.org/wiki/Thermoplastic-sheathed_cable (opens in a new tab)NM was first listed and described in the NEC in 1926, but it was invented a few years earlier by the Rome Wire Company in 1922 in Rome, New York
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.