Year Built

Often present · Electrical

Fuse box and 60-amp service

Houses built from 1940 through 1965 commonly got a 60-amp fuse box with four screw-in fuses; after 1965, 100-amp service became common.

Houses built
1965 or earlier
Dates from
Approximate era: Dates are an approximate era drawn from trade and reference sources.
How common
No reliable count exists
Priority
Worth a look
Mainly about
Safety
Where to look
Electrical panel

What it is

A 60-amp fuse box was typical in houses built from 1940 through 1965, after which 100-amp panels became common. The risks are over-fusing (a bigger fuse on a small circuit, which defeats the protection) and a service too small for modern loads. Many have been upgraded, but nobody counts how many.

How sure the dates are

Approximate era: Dates are an approximate era drawn from trade and reference sources.

Dates are an approximate era drawn from trade and reference sources. What the labels mean

How common it is

No reliable count exists

Most fused services of this era have probably been upgraded, but no data shows the share.

The years

Houses built in 1965 or earlier may have it. It is most likely in houses built 1940 to 1960.

Earliest
Before 1880No start date. It reaches back past 1880, where these records begin.
Most likely
1940–1960The years it is most common: the solid part of the band.
Latest
About 1965An approximate date. The change came gradually, so a few later houses may have it.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

How to check

  1. Find the main panel: round screw-in fuses, or pull-out blocks holding cartridge fuses, instead of rows of switches mean a fuse box.

  2. The service size is printed on the main pull-out or main fuse; look for '60'.

  3. If the main fuse or pull-out shows no rating, an electrician can confirm the service size.

Where to look
  • Electrical panel

What to do

If you find itHave a licensed electrician check that each fuse matches its wire size and assess the service. Upgrading to a 100- to 200-amp breaker service, which involves the utility, is the usual long-term fix. Never fit a larger fuse to stop one blowing.

Sources

1 verified source. Each quote is copied word for word from the page linked.

  1. WikipediaReference

    A common design of fuse box that was featured in homes built from 1940 through 1965 was the 60-amp fuse box that included four plug fuses

    en.wikipedia.org/wiki/Distribution_board (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Applies to houses built

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.