Federal Pacific Stab-Lok panels
Federal Pacific Stab-Lok breaker panels were made from 1950 to 1980, and CPSC's own testing found breakers that failed calibration tests.
- Houses built
- 1950–1990
- Dates from
- Approximate era: Dates are an approximate era drawn from trade and reference sources.
- How common
- No reliable count exists
- Priority
- Check first
- Mainly about
- Safety
- Where to look
- Electrical panel
What it is
Federal Pacific Electric made Stab-Lok breakers from 1950 to 1980, and they turn up mostly in houses built before 1990. CPSC opened an investigation in June 1980, confirmed that the breakers fail certain UL calibration tests, then closed the matter in 1983 without a recall and without deciding whether they are safe.
How sure the dates are
Approximate era: Dates are an approximate era drawn from trade and reference sources.Dates are an approximate era drawn from trade and reference sources. What the labels mean
How common it is
No reliable count existsClaims of 'millions of homes' come from advocacy sources, and no market-share data was found.
The years
Houses built from 1950 to 1990 may have it. It is most likely in houses built 1955 to 1980.
- Earliest
- About 1950An approximate date. It came in gradually, and sources differ by a few years.
- Most likely
- 1955–1980The years it is most common: the solid part of the band.
- Latest
- About 1990An approximate date. The change came gradually, so a few later houses may have it.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
How to check
Open the panel door (not the inner cover) and read the label for 'Federal Pacific Electric', 'FPE' or 'Federal Pioneer'.
Look for 'Stab-Lok' printed on or near the breakers.
Breaker handles often have a red or orange stripe across the tip.
- Electrical panel
What to do
If you find itHave a licensed electrician inspect it. Replacing the whole panel is the usual fix. There was never a recall, so there is no manufacturer remedy.
Sources
6 verified sources, 5 primary. Each quote is copied word for word from the page linked.
US CPSC (issued 3 Mar 1983; revised 18 Feb 2011)Primary source
cpsc.gov/Newsroom/News-Releases/1983/Commission-Close… (opens in a new tab)the Commission closed the matter without making a determination as to the safety of FPE circuit breakers or the accuracy of the manufacturer’s position on the matter
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Newsroom/News-Releases/1983/Commission-Close… (opens in a new tab)The Commission investigation into Federal Pacific Electric (FPE) circuit breakers began in June 1980
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Newsroom/News-Releases/1983/Commission-Close… (opens in a new tab)Commission testing confirmed that these breakers fail certain UL calibration test requirements.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Newsroom/News-Releases/1983/Commission-Close… (opens in a new tab)the data currently available to the Commission does not establish that the circuit breakers pose a serious risk of injury to consumers
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Newsroom/News-Releases/1983/Commission-Close… (opens in a new tab)The Commission staff believes that it currently has insufficient data to accept or refute Reliance’s position.
WikipediaReference
en.wikipedia.org/wiki/Stab-Lok (opens in a new tab)Stab-Lok is a brand name of electrical circuit breakers that were manufactured primarily by Federal Pacific Electric from 1950 to 1980.
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.