Often present · Electrical
Split-bus panels with no main breaker
Between the 1950s and the mid-1980s, many houses got a split-bus panel, which has no single main breaker: shutting off all the power can take up to six switches.
- Houses built
- 1950–1985
- Dates from
- Approximate era: Dates are an approximate era drawn from trade and reference sources.
- How common
- No reliable count exists
- Priority
- Good to know
- Mainly about
- Safety
- Where to look
- Electrical panel
What it is
A split-bus panel puts up to six large breakers in an upper group, one of which feeds a lower group of smaller breakers. Existing ones are allowed to stay, but there is no one-switch shutoff in an emergency and the panels are now decades old. Since the 2020 National Electrical Code, new services must have one main disconnect.
How sure the dates are
Approximate era: Dates are an approximate era drawn from trade and reference sources.Dates are an approximate era drawn from trade and reference sources. What the labels mean
How common it is
No reliable count existsNo reliable count exists, and the share of houses of the era with one is unknown.
The years
Houses built from 1950 to 1985 may have it. It is most likely in houses built 1960 to 1978.
- Earliest
- About 1950An approximate date. It came in gradually, and sources differ by a few years.
- Most likely
- 1960–1978The years it is most common: the solid part of the band.
- Latest
- About 1985An approximate date. The change came gradually, so a few later houses may have it.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
How to check
Open the panel door: there is no single large breaker marked 'Main'.
Instead you see a top group of up to six double-pole breakers, one often labeled 'Lighting Main' or 'Sub Main', and a separate lower group of single-pole breakers.
Read the brand on the label too, and check it against the Federal Pacific and Zinsco entries.
- Electrical panel
What to do
If you find itMake sure the breakers that shut off the house are clearly labeled. Have an electrician inspect it, and plan to replace it with a main-breaker panel when its condition calls for it or you add big loads such as an EV charger or heat pump.
Sources
1 verified source. Each quote is copied word for word from the page linked.
InterNACHITrade reference
nachi.org/inspect-main-electric-panelboard.htm (opens in a new tab)Between the 1950s and mid-1980s, split bus panels were installed in many homes. These panels do not have a main breaker or one main disconnect.
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.