Florida homes built before the statewide Florida Building Code took effect on March 1, 2002 were built to earlier local codes; the statewide code followed Hurricane Andrew.

Houses built without it
2002 or earlier
Dates from
Approximate era: Dates are an approximate era drawn from trade and reference sources.
How common
Likely
Priority
Worth a look
Mainly about
Safety
Where to look
Attic · Roof · Windows

What it is

After Hurricane Andrew, South Florida created High-Velocity Hurricane Zones in its 1994 code, and the statewide Florida Building Code took effect March 1, 2002. Older homes may have roofs held to the walls only by nails rather than metal straps, and no protection over windows and doors. A wind-mitigation inspection documents what a house actually has.

How sure the dates are

Approximate era: Dates are an approximate era drawn from trade and reference sources.

Dates are an approximate era drawn from trade and reference sources. What the labels mean

How common it is

Likely

Wikipedia puts the number of Florida homes that predate the modern code at about 4.7 million; every Florida home built before March 2002 predates it.

The years

Houses built in 2002 or earlier were built without it, unless it has been added since.

Earliest
Before 1880No start date. It reaches back past 1880, where these records begin.
Most likely
Not narrowedSources give no narrower window, so treat every year in the range alike.
Latest
About 2002An approximate date. Places adopted the requirement at different times.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

Regional

This applies to houses in Florida, not nationwide. Reports hide it when you choose another state.

How to check

  1. In the attic at the eaves, look where each truss or rafter meets the top of the wall.

  2. Only angled nails means toe-nailed; a small metal bracket is a clip; a metal strap wrapping over the truss is a wrap, and two straps a double wrap.

  3. Check windows and doors for impact-rated labels or shutter hardware.

  4. Your county permit record gives the original permit date.

Where to look
  • Attic
  • Roof
  • Windows

What to do

If it was never addedGet a wind-mitigation inspection by a licensed inspector; it records these features for your insurer. Upgrades such as roof-to-wall straps, re-nailing the roof deck and shutters are usually done at re-roofing time.

Sources

4 verified sources. Each quote is copied word for word from the page linked.

  1. Wikipedia (Effects of Hurricane Andrew in Florida)Reference

    The Florida Building Code was established in 1998 and put into effect by 2002.

    en.wikipedia.org/wiki/Effects_of_Hurricane_Andrew_in_… (opens in a new tab)
  2. Wikipedia (Florida Building Code)Reference

    no homes built after the unified Florida Building Code (FBC) was adopted March 1, 2002 were destroyed

    en.wikipedia.org/wiki/Florida_Building_Code (opens in a new tab)
  3. Wikipedia (Florida Building Code)Reference

    The 1994 South Florida Building Code created High-Velocity Hurricane Zones (HVHZ) and each subsequent major hurricane prompted specific changes to the code.

    en.wikipedia.org/wiki/Florida_Building_Code (opens in a new tab)
  4. Wikipedia (Florida Building Code)Reference

    Approximately 4.7 million homes in Florida predate the modern FBC.