Check firstOften present · Electrical
Knob-and-tube wiring
Many houses wired before about 1940 started out with single wires strung on porcelain knobs, no ground wire, and insulation that is now more than 80 years old.
- Houses built
- 1945 or earlier
- Dates from
- Approximate era: Dates are an approximate era drawn from trade and reference sources.
- How common
- No reliable count exists
- Priority
- Check first
- Mainly about
- Safety
- Where to look
- Attic · Basement & foundation · Wiring & outlets · Electrical panel
What it is
Knob-and-tube was the standard way to wire a house from about 1880 into the 1940s: separate cloth-covered wires run on ceramic knobs and through ceramic tubes, with no ground. The insulation gets brittle with age, and the US Department of Energy says active knob-and-tube should be replaced before insulation is added around it. Many houses were only partly rewired, so old runs can survive in walls and attics.
How sure the dates are
Approximate era: Dates are an approximate era drawn from trade and reference sources.Dates are an approximate era drawn from trade and reference sources. What the labels mean
How common it is
No reliable count existsA house wired between about 1900 and 1930 most likely started with it; how much is still live depends on later rewiring, which nobody tracks.
The years
Houses built in 1945 or earlier may have it. It is most likely in houses built 1900 to 1930.
- Earliest
- Before 1880No start date. It reaches back past 1880, where these records begin.
- Most likely
- 1900–1930The years it is most common: the solid part of the band.
- Latest
- About 1945An approximate date. The change came gradually, so a few later houses may have it.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
How to check
In the unfinished basement ceiling or the attic, look for white ceramic knobs nailed to the joists and ceramic tubes passing through them.
Look for two separate cloth-covered wires running several inches apart, rather than one plastic-sheathed cable.
Supporting clues: push-button light switches, two-slot outlets and a fuse box.
Modern cable at the panel does not rule it out, because knob-and-tube is often spliced in further along the circuit.
- Attic
- Basement & foundation
- Wiring & outlets
- Electrical panel
What to do
If you find itHave a licensed electrician find out which circuits are still live, especially before adding insulation, and keep insulation off any live runs. Replacing those circuits is the usual fix. Talk to your insurer early: InterNACHI notes that many insurers refuse to cover active knob-and-tube.
Sources
3 verified sources, 1 primary. Each quote is copied word for word from the page linked.
US Department of Energy, Building Technologies Program, "Energy Renovations: Insulation" guidePrimary source
energy.gov/sites/prod/files/2013/11/f5/insulation_gui… (opens in a new tab)For fire safety, active knob-and-tube wiring should be replaced before your contractor begins the insulation project.
InterNACHITrade reference
nachi.org/knob-and-tube (opens in a new tab)in common use in North America from about 1880 to the 1940s
WikipediaReference
en.wikipedia.org/wiki/Knob-and-tube_wiring (opens in a new tab)It was common in North America and Japan starting in the 1880s, remaining prevalent until the 1940s in North America
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.