Year Built

Built without · Electrical

Missing GFCI shock protection

CPSC says houses built before 1973 have no GFCI shock protection unless it was added later, and the code then added it one area at a time: bathrooms in 1975, garages in 1978, some kitchen outlets in 1987.

Houses built without it
1992 or earlier
Dates from
Federal rule: Dates come from a federal rule or a model building code.
How common
No reliable count exists
Priority
Worth a look
Mainly about
Safety
Where to look
Bathroom · Kitchen · Garage · Exterior walls · Basement & foundation · Electrical panel

What it is

A GFCI cuts the power in a fraction of a second when current leaks to ground, the kind of fault that electrocutes people near water. CPSC dates the requirements: outdoor outlets 1973, bathrooms 1975, garages 1978, some kitchen outlets 1987, unfinished basements and crawl spaces 1990. A house built before a given year was not required to have protection there unless it was added later.

How sure the dates are

Federal rule: Dates come from a federal rule or a model building code.

Dates come from a federal rule or a model building code. What the labels mean

How common it is

No reliable count exists

No reliable count exists on how many older houses have had GFCIs added. CPSC notes that houses built before 1973 have no GFCI protection unless it was installed later.

The years

Houses built in 1992 or earlier were built without it, unless it has been added since. The gap is most common in houses built 1972 or earlier.

Earliest
Before 1880No start date. It reaches back past 1880, where these records begin.
Most likely
To 1972The years when houses most often went without it.
Latest
About 1992An approximate date. Places adopted the requirement at different times.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

Year predicts poorly

Many older houses have had this added since, so the build year says little about whether yours has it now. Check either way.

How to check

  1. Look for outlets with TEST and RESET buttons in bathrooms, at kitchen counters, in the garage, outdoors, in the basement and in the laundry.

  2. Check the panel for breakers with a test button; a GFCI breaker protects a whole circuit.

  3. One GFCI can protect ordinary-looking outlets further along the circuit: press TEST and see which outlets go dead.

  4. Press RESET afterwards. A GFCI that does not trip when you press TEST needs replacing.

Where to look
  • Bathroom
  • Kitchen
  • Garage
  • Exterior walls
  • Basement & foundation
  • Electrical panel

What to do

If it was never addedAn electrician can add GFCI outlets or breakers where they are missing; they are allowed on ungrounded circuits too. Replace any GFCI that does not trip when tested.

Sources

4 verified sources, 2 primary. Each quote is copied word for word from the page linked.

  1. US CPSC Fact Sheet "What is a GFCI?"Primary source

    Outdoors (since 1973)

    cpsc.gov/s3fs-public/099_0.pdf (opens in a new tab)
  2. US CPSC news release, May 21, 1991Primary source

    GFCIs were first required in outdoor receptacle circuits in 1973, bathrooms in 1975, garage wall outlets in 1978, some kitchen receptacles since 1987, and all receptacle outlets in unfinished basements and crawl spaces since 1990.

    cpsc.gov/Newsroom/News-Releases/1991/Electrical-Safet… (opens in a new tab)
  3. InterNACHITrade reference

    Throughout the 1970s, GFCI installation requirements were gradually added for 120-volt receptacles in areas prone to possible water contact, including bathrooms, garages, and any receptacles located outdoors.

    nachi.org/gfci.htm (opens in a new tab)
  4. WikipediaReference

    garages (1978), areas near hot tubs or spas (1981), hotel bathrooms (1984), kitchen counter sockets (1987), crawl spaces and unfinished basements (1990), near wet bar sinks (1993), near laundry sinks (2005)

    en.wikipedia.org/wiki/Residual-current_device (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Reports for houses built without it

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.