Missing or outdated smoke alarms

Model building codes began requiring smoke alarms in every bedroom, linked so one sets off the rest, in 1988, so many older houses were built with far fewer.

Houses built without it
1995 or earlier
Dates from
Approximate era: Dates are an approximate era drawn from trade and reference sources.
How common
No reliable count exists
Priority
Check first
Mainly about
Safety
Where to look
Whole house

What it is

Smoke alarms went from 10% of US homes in 1975 to at least 92% by 2000, according to NIST. Codes then raised the bar: interconnected alarms in all sleeping rooms under the 1988 model codes, and alarms in all bedrooms under NFPA 72 from 1993. Alarms also wear out and should be replaced every 10 years.

How sure the dates are

Approximate era: Dates are an approximate era drawn from trade and reference sources.

Dates are an approximate era drawn from trade and reference sources. What the labels mean

How common it is

No reliable count exists

No reliable count exists of houses with alarms in every bedroom. NIST: the share of homes with at least one smoke alarm rose from 10% in 1975 to at least 92% by 2000.

The years

Houses built in 1995 or earlier were built without it, unless it has been added since. The gap is most common in houses built 1987 or earlier.

Earliest
Before 1880No start date. It reaches back past 1880, where these records begin.
Most likely
To 1987The years when houses most often went without it.
Latest
About 1995An approximate date. Places adopted the requirement at different times.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

Year predicts poorly

Many older houses have had this added since, so the build year says little about whether yours has it now. Check either way.

How to check

  1. Count them: one in each bedroom, one outside each sleeping area, and one on every level including the basement.

  2. Press TEST on one: if all of them sound, they are interconnected.

  3. Twist one off its base: a wiring plug behind it means hard-wired; none means battery-only.

  4. Check the manufacture date on the back; over 10 years old means replace it.

Where to look
  • Whole house

What to do

If it was never addedAdd alarms to every bedroom, hallway and level, using interconnected units; wireless interconnected alarms avoid new wiring. Replace any alarm over 10 years old.

Sources

5 verified sources, 2 primary. Each quote is copied word for word from the page linked.

  1. NISTPrimary source

    Between 1975 and 2000, the share of homes with a smoke alarm rose from 10% to at least 92%

    nist.gov/fire/history/driving-residential-smoke-alarm… (opens in a new tab)
  2. NISTPrimary source

    Between 1975 and 2000, the share of homes with a smoke alarm rose from 10% to at least 92%

    nist.gov/fire/history/1970s/driving-residential-smoke… (opens in a new tab)
  3. InterNACHI, Smoke Alarm InspectionTrade reference

    Smoke alarms should be replaced when they fail to respond to testing, or every 10 years, whichever is sooner.

    nachi.org/smoke-alarm-inspection.htm (opens in a new tab)
  4. Wikipedia, Smoke detectorReference

    In 1988 BOCA, ICBO, and SBCCI model building codes begin requiring smoke alarms to be interconnected and located in all sleeping rooms.

    en.wikipedia.org/wiki/Smoke_detector (opens in a new tab)
  5. WikipediaReference

    In 1989 NFPA 74 first required smoke alarms to be interconnected in every new home construction, and 1993 NFPA 72 first required that smoke alarms be installed in all bedrooms.

    en.wikipedia.org/wiki/Smoke_detector (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Reports for houses built without it

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.