Year Built

Built without · Roof, walls & windows

Built before mandatory airtightness testing (2012 energy code)

The 2012 energy code was the first to make new houses pass a whole-house air leakage test.

Houses built without it
2015 or earlier
Dates from
Federal rule: Dates come from a federal rule or a model building code.
How common
Likely
Priority
Good to know
Mainly about
Comfort
Where to look
Whole house · Attic

What it is

The 2012 International Energy Conservation Code added a mandatory whole-house pressure (blower-door) test, and DOE put it at about 30 percent more efficient than the 2006 code. A house built before its state adopted the 2012 code was not held to that test, so it may leak more air.

How sure the dates are

Federal rule: Dates come from a federal rule or a model building code.

Dates come from a federal rule or a model building code. What the labels mean

How common it is

Likely

Houses built before their state adopted the 2012 code were not required to pass this test. Adoption dates by state were not researched.

The years

Houses built in 2015 or earlier were built without it, unless it has been added since.

Earliest
Before 1880No start date. It reaches back past 1880, where these records begin.
Most likely
Not narrowedSources give no narrower window, so treat every year in the range alike.
Latest
About 2015An approximate date. Places adopted the requirement at different times.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

How to check

  1. Look near the electrical panel or furnace for an energy code certificate or a posted blower-door test result.

  2. Ask the seller or builder whether a blower-door test or energy rating was done.

  3. Notice drafts around outlets, attic hatches, recessed lights and window trim on a cold or windy day.

Where to look
  • Whole house
  • Attic

What to do

If it was never addedNothing is required. If the house feels drafty or bills are high, an energy audit with a blower-door test shows where air sealing would help most.

Sources

3 verified sources, 2 primary. Each quote is copied word for word from the page linked.

  1. U.S. Department of EnergyPrimary source

    Mandatory whole-house pressure test

    energy.gov/sites/prod/files/2013/12/f6/iecc_overview.pdf (opens in a new tab)
  2. U.S. Department of EnergyPrimary source

    ~30% better than 2006 IECC

    energy.gov/sites/prod/files/2013/12/f6/iecc_overview.pdf (opens in a new tab)
  3. WikipediaReference

    In the US, the IECC of 2012 adopted whole building airtightness requirements, including mandatory testing.

    en.wikipedia.org/wiki/Building_airtightness (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Reports for houses built without it

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.