Year Built

Built without · Electrical

Garage door opener without auto-reverse

Garage door openers made before 1991 did not have to reverse when they hit something, and photo-eyes or similar protection became required on openers made from 1993.

Houses built without it
1992 or earlier
Dates from
Federal rule: Dates come from a federal rule or a model building code.
How common
No reliable count exists
Priority
Worth a look
Mainly about
Safety
Where to look
Garage

What it is

CPSC reported 54 children killed since 1982 after being trapped under doors with automatic openers. Federal law required openers made from January 1, 1991 to reverse on contact, and openers made from January 1, 1993 to add protection such as photo-eye sensors. It is the opener's age that matters, not the house's.

How sure the dates are

Federal rule: Dates come from a federal rule or a model building code.

Dates come from a federal rule or a model building code. What the labels mean

How common it is

No reliable count exists

No reliable count exists of pre-1993 openers still in use.

The years

Houses built in 1992 or earlier were built without it, unless it has been added since. The gap is most common in houses built 1990 or earlier.

Earliest
Before 1880No start date. It reaches back past 1880, where these records begin.
Most likely
To 1990The years when houses most often went without it.
Latest
1992A fixed date: after this, a rule or model code called for it.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

Year predicts poorly

Many older houses have had this added since, so the build year says little about whether yours has it now. Check either way.

How to check

  1. Look for two small sensor 'eyes' near the floor on each side of the garage door opening.

  2. Check the date on the opener's label.

  3. Test it: lay a 2x4 flat on the floor under the door; the door should reverse when it touches the board.

Where to look
  • Garage

What to do

If it was never addedIf the opener does not reverse or has no sensors, replace it with a current UL 325-compliant unit rather than trying to retrofit it. Until then, keep children clear of the door while it moves.

Sources

4 verified sources, 3 primary. Each quote is copied word for word from the page linked.

  1. CPSC (final rule release dated 3 December 1992)Primary source

    The legislation also requires that residential garage door openers manufactured on or after January 1, 1993 comply with additional entrapment protection requirements developed by UL.

    cpsc.gov/Newsroom/News-Releases/1993/Safety-Commissio… (opens in a new tab)
  2. 16 CFR Part 1211 (2023 edition, via govinfo; ecfr.gov refuses automated requests)Primary source

    This standard applies to all residential garage door operators manufactured on or after January 1, 1993 for sale in the United States.

    govinfo.gov/content/pkg/CFR-2023-title16-vol2/pdf/CFR… (opens in a new tab)
  3. CPSC (proposal release dated 18 March 1992)Primary source

    all automatic residential garage door openers manufactured on or after January 1, 1991 must conform to the entrapment protection requirements of the Underwriters Laboratories (UL) Standard for Safety, UL 325

    cpsc.gov/Newsroom/News-Releases/1992/Safety-Commissio… (opens in a new tab)
  4. Wikipedia, Garage door openerReference

    A requirement for redundant entrapment-prevention devices was added in 1993

    en.wikipedia.org/wiki/Garage_door_opener (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Reports for houses built without it

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.