Often present · Hazardous materials
PCBs in old fluorescent light ballasts
Fluorescent light ballasts made before July 2, 1979 may contain PCBs, and EPA required PCB-free ballasts made from July 1978 to July 1998 to be marked 'No PCBs'.
- Houses built
- 1950–1979
- Dates from
- Federal rule: Dates come from a federal rule or a model building code.
- How common
- No reliable count exists
- Priority
- Good to know
- Mainly about
- Safety
- Where to look
- Garage · Basement & foundation · Kitchen
What it is
EPA says PCB-containing building materials may have been widely used in buildings built or renovated between about 1950 and 1979, and that fluorescent light ballasts made before July 2, 1979 may contain PCBs. In a house the realistic case is an original fluorescent fixture in a garage, basement, kitchen or workshop. PCB caulk is documented mainly in schools and larger buildings.
How sure the dates are
Federal rule: Dates come from a federal rule or a model building code.Dates come from a federal rule or a model building code. What the labels mean
How common it is
No reliable count existsNo reliable count exists for houses; EPA's material is about schools and other larger buildings.
The years
Houses built from 1950 to 1979 may have it.
- Earliest
- About 1950An approximate date. It came in gradually, and sources differ by a few years.
- Most likely
- Not narrowedSources give no narrower window, so treat every year in the range alike.
- Latest
- 1979A fixed date, such as a ban, a recall or a code change.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
How to check
Turn the power off, open the fluorescent fixture cover and read the ballast label.
A 'No PCBs' label means the ballast is PCB-free. EPA required that label on PCB-free ballasts made from July 1978 to July 1998, so a later ballast may have no label at all.
An unlabeled magnetic ballast, or oily or tarry leakage, suggests a PCB ballast. Only magnetic T12 ballasts may contain PCBs.
- Garage
- Basement & foundation
- Kitchen
What to do
If you find itReplace the old fixture or ballast, and take a PCB ballast to a hazardous-waste collection rather than the trash. Before renovating a 1950 to 1979 masonry apartment building, have suspect caulk tested.
Sources
4 verified sources, 4 primary. Each quote is copied word for word from the page linked.
US EPA, PCBs in Building MaterialsPrimary source
epa.gov/pcbs/polychlorinated-biphenyls-pcbs-building-… (opens in a new tab)potential widespread use of PCB-containing building materials in schools and other buildings constructed or renovated between about 1950 and 1979
US EPA, PCB-Containing Fluorescent Light Ballasts in School BuildingsPrimary source
epa.gov/pcbs/polychlorinated-biphenyl-pcb-containing-… (opens in a new tab)EPA regulations also require that all FLBs built between July 1, 1979, and July 1, 1998, that do not contain PCBs must be labeled "No PCBs."
U.S. Environmental Protection AgencyPrimary source
epa.gov/sites/default/files/2020-07/documents/pcb-flb… (opens in a new tab)Any FLBs manufactured before July 2, 1979, may contain PCBs.
U.S. Environmental Protection AgencyPrimary source
epa.gov/sites/default/files/2020-07/documents/pcb-flb… (opens in a new tab)between July 1, 1978 and July 1, 1998, to mark the ballasts that do not contain PCBs with the statement "No PCBs".
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.