Year Built

Report · houses built in

What a house built in 1887 often has

Age
139yrs
On record
29
Check first
5
Built without
12

Choose one to hide issues that only apply elsewhere.

About your house

A few optional answers make this report specific to one house.

0 of 11 questions answered.

Headline findingCheck first

Lead paint

Built 1978 or earlier · 1887 is in the peak yearsFederal rule: Dates come from a federal rule or a model building code.

EPA says 87% of homes built before 1940 have some lead-based paint, and lead paint for homes was banned only in 1978.

Lead paint: built 1978 or earlier; the line is 1887.

29 things on record apply to a 1887 house: 5 to check first, 12 protections it was built without, and 13 more by part of the house.

Where 1887 sits among every issue on record

Point at a band to read it · drag or use the arrow keys to compare years
What the 1887 line crosses29 bands
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

Check these first

The 5 items most worth a look in a 1887 house: safety first, then cost.

  1. Check firstOften present

    Lead paint

    EPA says 87% of homes built before 1940 have some lead-based paint, and lead paint for homes was banned only in 1978.

    How to checkWalls, ceilings & floors · Windows · Exterior walls · Whole house
    1. You cannot identify lead paint by sight; it takes an XRF test by a certified inspector or a lab paint-chip test.
    2. The most likely places are original windows, doors, trim, porches and exterior siding.
    3. Warning signs are many layers of old paint, a cracked 'alligator' pattern, or chalking.

    If you find itIf young children live in the house or you plan to renovate, get a lead inspection or risk assessment. Under EPA's Renovation, Repair and Painting rule, anyone paid to disturb paint in a pre-1978 home must be certified; the rule generally does not apply to owners working on their own home. Options range from stabilizing and repainting to abatement by certified firms; do not dry-sand or scrape old paint yourself.

    How commonEPA: 87% of homes built before 1940 and 24% of homes built from 1960 to 1978 have some lead-based paint. HUD's national survey found it in 34.6 million homes, 29.4% of all US housing.

    Keep in mindPaint made before the ban could still be applied in 1978 and a little later. Most houses built from 1960 to 1978 do not have lead paint; the share is far higher in older houses.

    Details and 9 sources →

    Built 1978 or earlier1887 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.Likely
  2. Check firstOften present

    Lead water service line

    The pipe that brings water from the street into many older houses is made of lead, and EPA estimates about 4 million of these lines are still in use.

    How to checkWater pipes · Basement & foundation
    1. Find where the water pipe enters the house, usually in the basement or crawl space near the meter.
    2. Lead is dull gray and soft: scratch it gently with a coin or key and it shows shiny silver. A magnet will not stick, and joints often have a bulging 'wiped' shape.
    3. Galvanized steel is gray but hard and magnetic; copper is the color of a penny.
    4. Look up your address in the water utility's public service line inventory.

    If you find itIf you find lead, or the utility lists your line as lead or unknown, use a filter certified to NSF/ANSI 53 for lead for drinking and cooking water, and ask the utility about replacement programs. EPA puts full replacement at $1,200 to $12,300 per line, averaging $4,700. Replace the whole line, not just part of it.

    How commonEPA's 2025 estimate is about 4 million lead service lines nationwide, a count that includes galvanized lines EPA treats as lead; its 2023 survey estimated 9.2 million. They are concentrated in older cities, and no figure gives the share by build year.

    Keep in mindWhether a given house has a lead line depends much more on the city than on the year: a trade source says lead was rarely used after about 1950, but the federal ban did not come until 1986. EPA's national estimates have also changed sharply between surveys.

    Details and 9 sources →

    Built 1986 or earlier1887 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.Possible
  3. Check firstBuilt without

    Missing or outdated smoke alarms

    Model building codes began requiring smoke alarms in every bedroom, linked so one sets off the rest, in 1988, so many older houses were built with far fewer.

    How to checkWhole house
    1. Count them: one in each bedroom, one outside each sleeping area, and one on every level including the basement.
    2. Press TEST on one: if all of them sound, they are interconnected.
    3. Twist one off its base: a wiring plug behind it means hard-wired; none means battery-only.
    4. Check the manufacture date on the back; over 10 years old means replace it.

    If you find itAdd alarms to every bedroom, hallway and level, using interconnected units; wireless interconnected alarms avoid new wiring. Replace any alarm over 10 years old.

    How commonNo reliable count exists of houses with alarms in every bedroom. NIST: the share of homes with at least one smoke alarm rose from 10% in 1975 to at least 92% by 2000.

    Keep in mindThe code dates come from reference sources and varied by code family and local adoption, so 1988 to 1993 is a transition and later is possible. Many older houses have been upgraded since.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 5 sources →

    Built 1995 or earlier1887 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists
  4. Check firstOften present

    Knob-and-tube wiring

    Many houses wired before about 1940 started out with single wires strung on porcelain knobs, no ground wire, and insulation that is now more than 80 years old.

    How to checkAttic · Basement & foundation · Wiring & outlets · Electrical panel
    1. In the unfinished basement ceiling or the attic, look for white ceramic knobs nailed to the joists and ceramic tubes passing through them.
    2. Look for two separate cloth-covered wires running several inches apart, rather than one plastic-sheathed cable.
    3. Supporting clues: push-button light switches, two-slot outlets and a fuse box.
    4. Modern cable at the panel does not rule it out, because knob-and-tube is often spliced in further along the circuit.

    If you find itHave a licensed electrician find out which circuits are still live, especially before adding insulation, and keep insulation off any live runs. Replacing those circuits is the usual fix. Talk to your insurer early: InterNACHI notes that many insurers refuse to cover active knob-and-tube.

    How commonNo reliable count exists. A house wired between about 1900 and 1930 most likely started with it; how much is still live depends on later rewiring, which nobody tracks.

    Keep in mindSources put the end of new installs anywhere from about 1930 (DOE) to the 1940s (trade and reference sources), so the end date is soft. Many houses of this age have been fully or partly rewired.

    Details and 3 sources →

    Built 1945 or earliermost likely 1900–1930

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists
  5. Check firstOften present

    Vermiculite attic insulation

    Loose, pebbly vermiculite insulation in the attic, often sold as Zonolite, may contain asbestos, and EPA advises treating it as if it does.

    How to checkAttic
    1. Look into the attic from the hatch without stepping in or disturbing anything.
    2. Vermiculite is loose, lightweight granules about 1/8 to 1/2 inch, shiny and accordion-like, gray-brown to silver-gold, lying between the joists.
    3. It is often under newer fiberglass or cellulose. InterNACHI tells inspectors that empty Zonolite bags left in the attic are a clue.
    4. EPA advises against relying on a negative lab test.

    If you find itLeave it undisturbed, keep boxes and other stored items out of that attic, and do not try to remove it yourself. EPA advises hiring a professional asbestos contractor before any remodeling that would disturb it. Zonolite Attic Insulation claims against W.R. Grace were settled in its bankruptcy; this guide could not confirm whether any reimbursement is still offered.

    How commonWikipedia reports a US government estimate that vermiculite was used in more than 35 million homes; other estimates are far lower. Even the high figure is a minority of houses.

    Keep in mindThis was largely a do-it-yourself product added to existing houses, so build year is a weak guide. Most houses do not have it, and estimates of how many do disagree widely.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 10 sources →

    Built 1990 or earlier

    Approximate era: Dates are an approximate era drawn from trade and reference sources.Possible

Built without

Protections that became standard after 1887. A house keeps what it was built with unless someone added them, and many have been.

  • Garage door opener without auto-reverse

    Built 1992 or earlier · peakGarage door openers made before 1991 did not have to reverse when they hit something, and photo-eyes or similar protection became required on openers made from 1993.

    Garage door openers made before 1991 did not have to reverse when they hit something, and photo-eyes or similar protection became required on openers made from 1993.

    Read the full entry →

    Built 1992 or earlier1887 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look for two small sensor 'eyes' near the floor on each side of the garage door opening.
    2. Check the date on the opener's label.
    3. Test it: lay a 2x4 flat on the floor under the door; the door should reverse when it touches the board.

    If you find itIf the opener does not reverse or has no sensors, replace it with a current UL 325-compliant unit rather than trying to retrofit it. Until then, keep children clear of the door while it moves.

    How commonNo reliable count exists of pre-1993 openers still in use.

    Keep in mindThe 1993 rule can be met by a constant-contact wall button instead of photo-eyes, so a newer opener without eyes is possible. Openers are often added or replaced long after a house is built.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →
  • Missing GFCI shock protection

    Built 1992 or earlier · peakCPSC says houses built before 1973 have no GFCI shock protection unless it was added later, and the code then added it one area at a time: bathrooms in 1975, garages in 1978, some kitchen outlets in 1987.

    CPSC says houses built before 1973 have no GFCI shock protection unless it was added later, and the code then added it one area at a time: bathrooms in 1975, garages in 1978, some kitchen outlets in 1987.

    Read the full entry →

    Built 1992 or earlier1887 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look for outlets with TEST and RESET buttons in bathrooms, at kitchen counters, in the garage, outdoors, in the basement and in the laundry.
    2. Check the panel for breakers with a test button; a GFCI breaker protects a whole circuit.
    3. One GFCI can protect ordinary-looking outlets further along the circuit: press TEST and see which outlets go dead.
    4. Press RESET afterwards. A GFCI that does not trip when you press TEST needs replacing.

    If you find itAn electrician can add GFCI outlets or breakers where they are missing; they are allowed on ungrounded circuits too. Replace any GFCI that does not trip when tested.

    How commonNo reliable count exists on how many older houses have had GFCIs added. CPSC notes that houses built before 1973 have no GFCI protection unless it was installed later.

    Keep in mindThese are national code edition years. States and cities adopted each edition anywhere from the same year to several years later, so a house built just after a milestone may not have that protection. Many older houses have had GFCIs added since, so build year is only a rough guide.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →
  • Non-tempered glass in doors and showers

    Built 1977 or earlier · peakGlass in doors, sliding patio doors and shower enclosures has had to be safety glass since July 1977, so older original glass may be ordinary glass that can cause serious cuts if someone falls through it.

    Glass in doors, sliding patio doors and shower enclosures has had to be safety glass since July 1977, so older original glass may be ordinary glass that can cause serious cuts if someone falls through it.

    Read the full entry →

    Built 1977 or earlier1887 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look in each corner of the glass in doors, sliding doors and shower panels for a small etched or sandblasted mark naming the maker.
    2. A mark reading 'tempered', '16 CFR 1201' or 'ANSI Z97.1' means safety glass.
    3. No mark on a door or shower panel in an older house suggests ordinary glass.

    If you find itReplace unmarked glass in doors and showers with tempered or laminated safety glass, starting with the places people are most likely to fall against.

    How commonNo reliable count exists of original pre-1977 glass still in place.

    Keep in mindSome states may have had their own safety-glazing laws earlier; that was not confirmed. Many doors and shower enclosures have been replaced since 1977.

    Details and 3 sources →
  • Florida home built before the statewide wind code

    Built 2002 or earlierFLFlorida homes built before the statewide Florida Building Code took effect on March 1, 2002 were built to earlier local codes; the statewide code followed Hurricane Andrew.

    Florida homes built before the statewide Florida Building Code took effect on March 1, 2002 were built to earlier local codes; the statewide code followed Hurricane Andrew.

    Read the full entry →

    Built 2002 or earlier

    Approximate era: Dates are an approximate era drawn from trade and reference sources.Likely

    How to check

    1. In the attic at the eaves, look where each truss or rafter meets the top of the wall.
    2. Only angled nails means toe-nailed; a small metal bracket is a clip; a metal strap wrapping over the truss is a wrap, and two straps a double wrap.
    3. Check windows and doors for impact-rated labels or shutter hardware.
    4. Your county permit record gives the original permit date.

    If you find itGet a wind-mitigation inspection by a licensed inspector; it records these features for your insurer. Upgrades such as roof-to-wall straps, re-nailing the roof deck and shutters are usually done at re-roofing time.

    How commonWikipedia puts the number of Florida homes that predate the modern code at about 4.7 million; every Florida home built before March 2002 predates it.

    Keep in mindHouses finished around 2002 can go either way, depending on when they were approved. In South Florida's High-Velocity Hurricane Zones the stricter code dates from 1994. Some pre-2002 homes do have clips or straps.

    Details and 4 sources →
  • Gas water heaters made before 2003 (no flammable-vapor protection)

    Built 2003 or earlierStandard gas tank water heaters made after July 1, 2003 are built to resist igniting gasoline fumes; older ones are not.

    Standard gas tank water heaters made after July 1, 2003 are built to resist igniting gasoline fumes; older ones are not.

    Read the full entry →

    Built 2003 or earlier

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Check whether the water heater is a gas tank model (a burner at the bottom and a vent pipe on top).
    2. Read the label for the words 'Flammable Vapor Ignition Resistant' or 'FVIR'.
    3. Look for the manufacture date in the label or serial number: after July 2003 means it should have the protection.
    4. Notice whether gasoline, paint thinner or solvents are stored near it, especially in a garage.

    If you find itKeep gasoline and solvents well away from any gas appliance. If the heater predates the standard, plan to replace it with a current model.

    How commonAny gas tank heater made before July 2003 lacks it. Many heaters that old have been replaced; no count of how many remain exists.

    Keep in mindThis was a voluntary industry standard, not a federal law, and it covers standard 30, 40 and 50 gallon gas tank heaters. Water heaters are replaced often, so the heater's own date matters far more than the house's.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →
  • Mobile home built before the HUD Code

    Built 1976 or earlierMobile homes made before June 15, 1976 predate the federal HUD Code and cannot get FHA-insured mortgages.

    Mobile homes made before June 15, 1976 predate the federal HUD Code and cannot get FHA-insured mortgages.

    Read the full entry →

    Built 1976 or earlier

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look for a metal certification label, about 2 by 4 inches, riveted to the outside at the tail end of each section.
    2. Look for a paper data plate inside, often in a kitchen cabinet, the electrical panel or a bedroom closet, giving the manufacture date.
    3. No label and no data plate, plus a title showing a pre-1976 year, means pre-HUD Code.

    If you find itFocus on safety upgrades such as smoke alarms, a wiring evaluation and tie-downs. Expect financing limits: FHA insures only manufactured homes built on or after June 15, 1976, and HUD says a removed label cannot be reattached to make a home eligible.

    How commonNo reliable count exists of surviving pre-1976 units. Every mobile home made before the date predates the HUD Code by definition.

    Keep in mindThe date is when the home left the factory, not its model year or when it was placed, so a '1976' home can fall on either side.

    Details and 6 sources →
  • No arc-fault (AFCI) breakers

    Built 2004 or earlier · peakArc-fault breakers, which detect the sparking that can start wiring fires, were first required in bedrooms of new houses in 2002.

    Arc-fault breakers, which detect the sparking that can start wiring fires, were first required in bedrooms of new houses in 2002.

    Read the full entry →

    Built 2004 or earlier1887 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Open the panel door and look for breakers with a TEST button labeled AFCI, 'Arc Fault', 'Combination AFCI' or 'Dual Function'.
    2. Ordinary breakers have no test button.

    If you find itThis is an optional upgrade: an electrician can fit AFCI or dual-function breakers where your panel supports them.

    How commonNo reliable count exists. Houses built before about 2002 will lack AFCIs unless they were added later.

    Keep in mindStates adopt each code edition on their own schedule, so build year is a weak guide on its own. Only the 2002 bedroom date is confirmed by a primary source.

    Details and 2 sources →
  • Outlets without child-safety shutters

    Built 2010 or earlier · peakSince the 2008 electrical code, new houses get outlets with built-in shutters that stop a child pushing a key or hairpin into the slot.

    Since the 2008 electrical code, new houses get outlets with built-in shutters that stop a child pushing a key or hairpin into the slot.

    Read the full entry →

    Built 2010 or earlier1887 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look closely at an outlet: 'TR' embossed on the face between the slots means tamper-resistant.
    2. You can see plastic shutters inside the slots.

    If you find itIf small children live in or visit the house, have outlets replaced with TR-listed ones.

    How commonNo reliable count exists. Houses built before their state adopted the 2008 code will generally lack them unless outlets were replaced.

    Keep in mind2008 is the model code year; states adopted it at different times. As of 2016, the rule did not apply to manufactured homes.

    Details and 3 sources →
  • Built before energy codes

    Built 1979 or earlier · peakThe first US energy standard for buildings, ASHRAE 90, was published in 1975, so a house built before then was not built to any energy code.

    The first US energy standard for buildings, ASHRAE 90, was published in 1975, so a house built before then was not built to any energy code.

    Read the full entry →

    Built 1979 or earlier1887 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Look in the attic at the depth of insulation between and over the joists.
    2. Check what kind of glass the windows have: single pane or double pane.

    If you find itAn energy audit shows where the house loses heat. Air sealing and attic insulation usually come first, then wall insulation.

    How commonNo reliable count exists of how many older houses have been upgraded. A house built before 1975 was built without any energy code.

    Keep in mind1975 is when the first standard was published, not when your state enforced one, and states adopted energy codes on their own schedules. Later code dates were not confirmed.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →
  • Manufactured home built before 1994 wind standards

    Built 1994 or earlierAfter Hurricane Andrew, HUD raised the wind standards for manufactured homes made from July 13, 1994, with zones designed for 100 and 110 mph winds.

    After Hurricane Andrew, HUD raised the wind standards for manufactured homes made from July 13, 1994, with zones designed for 100 and 110 mph winds.

    Read the full entry →

    Built 1994 or earlier

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Find the data plate inside the home, often in a kitchen cabinet, the electrical panel or a bedroom closet.
    2. Read the manufacture date and the wind-zone map showing which zone (I, II or III) the home was designed for.
    3. No wind-zone designation, or a date before July 1994, means the older standard.

    If you find itHave the anchoring and tie-downs checked and brought up to current installation standards. Only replacement gets you the post-1994 structural design.

    How commonNo reliable count exists. Every manufactured home made before the date was built to the older standard.

    Keep in mindDate of manufacture governs, not the year the home was placed. Exactly which counties fall in each wind zone was not confirmed; the higher zones cover the hurricane coast.

    Details and 2 sources →
  • Built before mandatory airtightness testing (2012 energy code)

    Built 2015 or earlierThe 2012 energy code was the first to make new houses pass a whole-house air leakage test.

    The 2012 energy code was the first to make new houses pass a whole-house air leakage test.

    Read the full entry →

    Built 2015 or earlier

    Federal rule: Dates come from a federal rule or a model building code.Likely

    How to check

    1. Look near the electrical panel or furnace for an energy code certificate or a posted blower-door test result.
    2. Ask the seller or builder whether a blower-door test or energy rating was done.
    3. Notice drafts around outlets, attic hatches, recessed lights and window trim on a cold or windy day.

    If you find itNothing is required. If the house feels drafty or bills are high, an energy audit with a blower-door test shows where air sealing would help most.

    How commonHouses built before their state adopted the 2012 code were not required to pass this test. Adoption dates by state were not researched.

    Keep in mindThis is a model code. States and cities adopted it at different times, so the end year here is stretched a few years and is soft. Check your state's adoption date.

    Details and 3 sources →

Everything else, by part of the house

Materials and products often installed in 1887. Open any row for how to check.

Where to look. Each number counts the items in this report for that part of the house.

Electrical2

  • Two-prong outlets with no ground

    Built 1966 or earlier · peakOutlets with only two slots were normal until 1962, when grounded outlets became required in new houses.

    Outlets with only two slots were normal until 1962, when grounded outlets became required in new houses.

    Read the full entry →

    Built 1966 or earlier1887 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Look at the outlets: two slots and no round ground hole means an ungrounded outlet.
    2. Where an older house has three-prong outlets, a plug-in outlet tester from a hardware store will show 'open ground' if no ground is connected.
    3. If an electrician opens the panel, old cables with only two conductors and no bare ground wire are another sign. Do not remove the panel cover yourself.

    If you find itAn electrician can run new grounded circuits, or protect ungrounded outlets with GFCI devices labeled 'No Equipment Ground', an accepted fix according to InterNACHI. A GFCI gives shock protection but is not a true ground.

    How commonNo reliable count exists. Before 1962 the code did not require grounded outlets, so a house of that age started with mostly two-wire circuits; how many have been rewired is unknown.

    Keep in mind1962 is the year trade and reference sources give for new construction; the 1974 date and local adoption lag mean some later houses may have two-wire circuits too. Many older houses have been partly rewired, or had three-prong outlets swapped in with no ground behind them.

    Details and 2 sources →
  • Fuse box and 60-amp service

    Built 1965 or earlierHouses built from 1940 through 1965 commonly got a 60-amp fuse box with four screw-in fuses; after 1965, 100-amp service became common.

    Houses built from 1940 through 1965 commonly got a 60-amp fuse box with four screw-in fuses; after 1965, 100-amp service became common.

    Read the full entry →

    Built 1965 or earliermost likely 1940–1960

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Find the main panel: round screw-in fuses, or pull-out blocks holding cartridge fuses, instead of rows of switches mean a fuse box.
    2. The service size is printed on the main pull-out or main fuse; look for '60'.
    3. If the main fuse or pull-out shows no rating, an electrician can confirm the service size.

    If you find itHave a licensed electrician check that each fuse matches its wire size and assess the service. Upgrading to a 100- to 200-amp breaker service, which involves the utility, is the usual long-term fix. Never fit a larger fuse to stop one blowing.

    How commonNo reliable count exists. Most fused services of this era have probably been upgraded, but no data shows the share.

    Keep in mindThe 1940 to 1965 range comes from one reference source, and the code history of the 100-amp minimum was not confirmed. Many houses of this era have had their service upgraded.

    Details and 1 source →

Plumbing & water1

  • Galvanized steel water pipes

    Built 1960 or earlier · peakGray, threaded galvanized steel was common for water pipes until the 1950s, and it rusts from the inside, slowly choking the flow.

    Gray, threaded galvanized steel was common for water pipes until the 1950s, and it rusts from the inside, slowly choking the flow.

    Read the full entry →

    Built 1960 or earlier1887 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Look at exposed pipe in the basement, crawl space or at the water heater: dull gray, with threaded fittings.
    2. A magnet sticks to it, and a scratch shows silver-gray steel, not copper color.
    3. Symptoms: low pressure on upper floors, rusty water after the taps sit unused, rust stains at joints.

    If you find itHave a plumber assess it. Repiping the house in copper or PEX is the usual remedy. If the service line is galvanized, check the utility's inventory for lead upstream.

    How commonNo reliable count exists for galvanized pipe inside houses. EPA estimated about 2.8 million standalone galvanized service lines in 2023.

    Keep in mindSources disagree by more than a decade on when galvanized stopped being used, and none is a code history. Many houses of this age have been repiped.

    Details and 3 sources →

Kitchen & bath2

  • Uncoated brass gas appliance connectors

    Built 1986 or earlierOld flexible brass gas connectors behind stoves, dryers and water heaters can crack, and CPSC linked them to 35 deaths.

    Old flexible brass gas connectors behind stoves, dryers and water heaters can crack, and CPSC linked them to 35 deaths.

    Read the full entry →

    Built 1986 or earlier

    Court record: Dates come from a court settlement or a product recall.No reliable count exists

    How to check

    1. CPSC says not to move a gas appliance to look; check only where the connector is already visible.
    2. An old connector is a dull brass-colored corrugated tube with no gray or yellow plastic coating.
    3. Modern connectors are stainless steel or coated.

    If you find itHave a qualified gas technician check the connectors on older appliances and replace any uncoated brass one. A connector should never be reused.

    How commonNo reliable count exists. Connectors are usually replaced with the appliance.

    Keep in mindCPSC gave no exact year manufacture stopped, only 'at least the past 10 years' as of 1996. The age of the appliance matters more than the age of the house.

    Details and 2 sources →
  • High-flow toilets and showerheads

    Built 1993 or earlierSince 1994, new toilets can use only 1.6 gallons per flush, less than half the water of most models in use before then.

    Since 1994, new toilets can use only 1.6 gallons per flush, less than half the water of most models in use before then.

    Read the full entry →

    Built 1993 or earlier

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Lift the toilet tank lid: the gallons per flush is usually stamped or printed inside the tank, or on the bowl behind the seat, with a manufacture date.
    2. '1.6 gpf / 6.0 Lpf' or lower means it meets the 1994 rule.
    3. No marking and a large tank suggest a pre-1994 toilet.

    If you find itIf you want lower water bills, replace with a WaterSense-labeled toilet and showerhead, and check whether your utility offers a rebate.

    How commonNo reliable count exists. Toilets and showerheads are replaced often, so many older houses already have newer ones.

    Keep in mindThe rule applied to fixtures made from January 1, 1994, so houses finished in 1994 may still have older stock. Fixtures are swapped so often that build year predicts this poorly.

    Details and 3 sources →

Heating, cooling & chimney2

  • Unlined masonry chimney

    Built 1955 or earlierChimneys built before the 1950s may have no flue liner, just bare brick, which can let a chimney fire or carbon monoxide reach the house.

    Chimneys built before the 1950s may have no flue liner, just bare brick, which can let a chimney fire or carbon monoxide reach the house.

    Read the full entry →

    Built 1955 or earlier

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. With the fire out and cold, look up from the fireplace or down from the clean-out with a flashlight.
    2. Bare brick and mortar means unlined; square orange or buff clay tiles mean lined.
    3. Cracked tiles usually need a camera inspection by a chimney professional.

    If you find itHave a certified chimney sweep inspect it before using the fireplace or connecting an appliance. Fixes include a stainless-steel or cast-in-place liner, new tiles, or closing off the flue.

    How commonNo reliable count exists of how many older chimneys are unlined.

    Keep in mindThere is no single national date; liner rules came in locally and gradually from about the 1950s. Many older chimneys have been relined since.

    Details and 2 sources →
  • R-22 (Freon) air conditioner

    Built 2009 or earlierSince January 1, 2010, EPA has barred making new air conditioners or pre-charged parts with R-22, and US production and import of the refrigerant ended in 2020.

    Since January 1, 2010, EPA has barred making new air conditioners or pre-charged parts with R-22, and US production and import of the refrigerant ended in 2020.

    Read the full entry →

    Built 2009 or earlier

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Read the data plate on the outdoor unit: 'R-22' or 'HCFC-22' means the old refrigerant; newer units say R-410A, R-454B or R-32.
    2. The manufacture date is usually on the same plate.

    If you find itNothing to do while it works. Budget for replacing the outdoor unit and indoor coil together when it fails.

    How commonNo reliable count exists of pre-2010 units still in service.

    Keep in mindAir conditioning is often added or replaced long after a house is built, so the unit's age matters far more than the house's.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 5 sources →

Exterior walls & windows2

  • Unreinforced brick (URM) houses

    Built 1975 or earlierUTAlong Utah's Wasatch Front, many solid-brick houses built before 1975 have no steel reinforcement, and FEMA counts over 185,000 such buildings in the Salt Lake Valley alone.

    Along Utah's Wasatch Front, many solid-brick houses built before 1975 have no steel reinforcement, and FEMA counts over 185,000 such buildings in the Salt Lake Valley alone.

    Read the full entry →

    Built 1975 or earlier

    Federal rule: Dates come from a federal rule or a model building code.Possible

    How to check

    1. Look at the outside brick walls: rows of bricks laid end-on (header courses) every few rows mean solid brick, not veneer.
    2. At a window opening, a wall much thicker than a single brick points to solid masonry.
    3. Star-shaped or square metal plates on the outside wall show past retrofit ties.
    4. Brick veneer over a wood frame has no header rows and is a different, lesser issue.

    If you find itHave a structural engineer assess it, and ask your city whether a local program helps pay for seismic retrofits such as roof-to-wall ties and chimney bracing.

    How commonFEMA P-774: over 185,000 unreinforced masonry buildings in the Salt Lake Valley alone, many of them single-family homes.

    Keep in mindShown for Utah, where the 1975 date is confirmed. California also has unreinforced brick buildings; seismic code requirements began there in the 1930s.

    Details and 5 sources →
  • Urea-formaldehyde foam insulation (UFFI)

    Built 1982 or earlierSome 500,000 homes already had foam insulation pumped into their walls when CPSC banned it in 1982, and a court overturned the ban the next year.

    Some 500,000 homes already had foam insulation pumped into their walls when CPSC banned it in 1982, and a court overturned the ban the next year.

    Read the full entry →

    Built 1982 or earlier

    Court record: Dates come from a court settlement or a product recall.Rare

    How to check

    1. Look on the outside walls for rows of patched 1- to 2-inch plugs in siding or mortar joints, where foam was injected.
    2. In the basement at the sill, or behind an outlet cover on an outside wall (power off first), look for dry, crumbly, off-white to tan foam that powders when touched.

    If you find itUsually nothing needs doing. If anyone has symptoms, an indoor air test for formaldehyde is the next step. Removal means opening the walls and is rarely justified on health grounds. Some state disclosure forms ask about UFFI, so keep a note.

    How commonA commissioner's statement in CPSC's 1982 release referred to some 500,000 homes already insulated with the foam, a small share of US housing.

    Keep in mindIt was installed in new houses and added to existing ones, so build year is a weak guide. The start years are approximate.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 8 sources →

Foundation & basement4

  • Balloon framing

    Built 1950 or earlier · peakIn many older two-story houses the wall cavities run unbroken from the basement to the attic, which lets a fire climb inside the walls.

    In many older two-story houses the wall cavities run unbroken from the basement to the attic, which lets a fire climb inside the walls.

    Read the full entry →

    Built 1950 or earlier1887 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. In the basement, look up where the floor joists meet the outside wall: open stud cavities rising past the joists, with no flat wooden plate on top, mean balloon framing.
    2. In the attic, look down between the studs at the eaves for open cavities.
    3. At the second floor, joists nailed to the sides of studs and resting on a board let into the studs are the giveaway.

    If you find itHave a contractor add fireblocking (lumber, mineral wool or dense-packed insulation) at the basement and attic ends of each stud cavity where they can be reached.

    How commonNo reliable count exists. The concern is mainly in houses of two or more stories, where wall cavities can run through several floors.

    Keep in mindThe end date varies: sources put it from the late 1940s to the mid-1950s, and timing differed by region and builder. Many houses of the 1930s and 1940s are platform framed.

    Details and 3 sources →
  • House not bolted to its foundation

    Built 1979 or earlier · peakCA OR WAMany older West Coast houses on crawl spaces may not be adequately bolted to their foundations, and in a strong earthquake they can slide off.

    Many older West Coast houses on crawl spaces may not be adequately bolted to their foundations, and in a strong earthquake they can slide off.

    Read the full entry →

    Built 1979 or earlier1887 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Go into the crawl space and look along the top of the concrete foundation at the wooden sill plate.
    2. Bolts with nuts and washers along the sill plate mean it is bolted.
    3. If there is a short wood-stud wall between the foundation and the floor, check whether plywood or OSB is nailed to its inside face.
    4. Houses on a concrete slab have no cripple wall.

    If you find itA contractor can bolt the sill and brace the cripple walls with plywood. Ask your city or county whether it publishes retrofit plans or has a program that helps pay for the work.

    How commonNo reliable count exists. Only houses on raised foundations with crawl spaces are affected; slab houses are not.

    Keep in mindThere is no single code year: a reference source says many structures built before 1950 may not be adequately bolted, and the 1979 end used here is an unconfirmed program screen, not a code date. Many houses have already been retrofitted.

    Details and 2 sources →
  • Asbestos pipe and boiler insulation

    Built 1975 or earlierCPSC says houses built between 1930 and 1950 may have asbestos insulation, often as white wrap on heating pipes and boilers in the basement.

    CPSC says houses built between 1930 and 1950 may have asbestos insulation, often as white wrap on heating pipes and boilers in the basement.

    Read the full entry →

    Built 1975 or earliermost likely 1930–1950

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. In the basement or crawl space, look for white or gray wrap on pipes that looks like corrugated cardboard in cross-section.
    2. Look for a hard white plaster-like coating on pipe elbows, boilers and tanks.
    3. Check duct seams and the edges of registers for white paper or cloth tape.
    4. Do not touch frayed material; only a lab test confirms asbestos.

    If you find itIf it is in good condition, a professional can seal and wrap it. If it is damaged, or before you replace a boiler or finish a basement, have it tested and handled by a licensed abatement contractor.

    How commonNo reliable count exists. It depends on whether the house still has an original steam or hot-water system, and much of this insulation has already been removed or sealed.

    Keep in mindCPSC lists steam pipes, boilers and furnace ducts wrapped in asbestos blanket or paper tape, but the sources give no clear end date for the duct tape and paper. Many houses of this era have had this insulation removed or sealed.

    Details and 4 sources →
  • Gravity ('octopus') furnace

    Built 1950 or earlierSome older basements still hold a huge round 'octopus' furnace with fat ducts reaching upward, and its duct wrap may contain asbestos.

    Some older basements still hold a huge round 'octopus' furnace with fat ducts reaching upward, and its duct wrap may contain asbestos.

    Read the full entry →

    Built 1950 or earlier

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. In the basement, look for a very large round or boxy furnace with several large sheet-metal ducts sloping up from the top and no blower compartment.
    2. White or gray cloth-like or corrugated-paper wrap on the ducts may be asbestos; do not disturb it.

    If you find itPlan for replacement: have any duct wrap tested and removed by a licensed asbestos abatement contractor, then install a modern furnace and ducts. InterNACHI advises buyers to negotiate the price to cover this.

    How commonNo reliable count exists of how many remain; most have been replaced.

    Keep in mindThe date range stands in for InterNACHI's 'late 1800s to the mid-20th century'. Most of these furnaces have long since been replaced.

    Details and 1 source →

What’s due at this age

A 1887 house is 139 years old. Here is where its parts stand against their typical life, and which ones have certainly been replaced by now.

In their window
0
Past life, if original
2
Due within 5 yrs
0
Replaced by now
46

46 of the 53 parts we track wear out so much faster than a 1887 house has stood that they have been replaced at least once. Know when something was last replaced? Enter the year (or a decade, like 2010s) and we’ll show where that part stands. It stays on this device only.

Past typical life, if still original

2

Older than the usual range, but not so old that an original is unlikely. Worth finding out whether they have been replaced.

  • Chimney flue tileChimney · lasts 40–120 yrs
    40–120 yrs19 yrs pastif original
  • Heating and cooling ductworkHeating & cooling · lasts 60–100 yrs
    60–100 yrs39 yrs pastif original
Replaced at least once by now: find out when46

A 1887 house has outlasted these parts’ typical life several times over, so what matters is when each was last replaced. Ask the seller or check receipts and date labels; enter a year and the part moves up to where it stands.

  • Carbon monoxide alarmWhole houselasts ~5 yrs≈27 lifetimes
  • Dryer vent (plastic)Whole houselasts ~5 yrs≈27 lifetimes
  • Sump pumpBasement & foundationlasts ~7 yrs≈19 lifetimes
  • DishwasherKitchenlasts ~9 yrs≈15 lifetimes
  • CarpetWalls, ceilings & floorslasts 8–10 yrs≈15 lifetimes
  • Caulking (interior and exterior)Exterior wallslasts 5–10 yrs≈18 lifetimes
  • Exterior paintExterior wallslasts 7–10 yrs≈16 lifetimes
  • Smoke alarmWhole houselasts ~10 yrs≈13 lifetimes
  • Garbage disposalKitchenlasts ~12 yrs≈11 lifetimes
  • Clothes dryerWhole houselasts ~13 yrs≈10 lifetimes
  • RefrigeratorKitchenlasts 9–13 yrs≈12 lifetimes
  • Central air conditionerHeating & coolinglasts 7–15 yrs≈12 lifetimes
  • Electric rangeKitchenlasts 13–15 yrs≈9 lifetimes
  • Garage door openerGaragelasts 10–15 yrs≈11 lifetimes
  • Heat pumpHeating & coolinglasts 10–15 yrs≈11 lifetimes
  • Tank water heaterWater heaterlasts 6–15 yrs≈13 lifetimes
  • Washing machineBathroomlasts 5–15 yrs≈13 lifetimes
  • Well pumpWater pipeslasts ~15 yrs≈9 lifetimes
  • Wood deck boardsDeck & yardlasts ~15 yrs≈9 lifetimes
  • Gas rangeKitchenlasts 15–17 yrs≈8 lifetimes
  • Aluminum windowsWindowslasts 15–20 yrs≈7 lifetimes
  • Asphalt drivewayDeck & yardlasts 15–20 yrs≈7 lifetimes
  • Asphalt shingle roof (3-tab)Rooflasts ~20 yrs≈6 lifetimes
  • Faucets and spray hoseBathroomlasts 15–20 yrs≈7 lifetimes
  • Flat roof (modified bitumen)Rooflasts ~20 yrs≈6 lifetimes
  • Tankless water heaterWater heaterlasts 10–20 yrs≈9 lifetimes
  • Water softenerWater pipeslasts ~20 yrs≈6 lifetimes
  • Flat roof (EPDM rubber)Rooflasts 15–25 yrs≈6 lifetimes
  • Forced-air furnaceHeating & coolinglasts 15–25 yrs≈6 lifetimes
  • Garage doorGaragelasts 20–25 yrs≈6 lifetimes
  • Vinyl floorWalls, ceilings & floorslasts ~25 yrs≈5 lifetimes
  • Wood shake roofRooflasts ~25 yrs≈5 lifetimes
  • Asphalt shingle roof (architectural)Rooflasts ~30 yrs≈4 lifetimes
  • Deck framingDeck & yardlasts 10–30 yrs≈6 lifetimes
  • GFCI outletsKitchenlasts ~30 yrs≈4 lifetimes
  • Wood windowsWindowslasts ~30 yrs≈4 lifetimes
  • Aluminum gutters and downspoutsRooflasts 20–40 yrs≈4 lifetimes
  • Boiler (hot-water or steam)Heating & coolinglasts ~40 yrs≈3 lifetimes
  • Septic systemDrains & sewerlasts 15–40 yrs≈5 lifetimes
  • Vinyl or fiberglass windowsWindowslasts 20–40 yrs≈4 lifetimes
  • Concrete walkwayDeck & yardlasts 40–50 yrs≈3 lifetimes
  • Cast-iron drain pipe (below ground)Drains & sewerlasts 50–60 yrs≈2 lifetimes
  • Electrical service panelElectrical panellasts ~60 yrs≈2 lifetimes
  • Vinyl sidingExterior wallslasts ~60 yrs≈2 lifetimes
  • Copper water supply linesWater pipeslasts 50–70 yrs≈2 lifetimes
  • Metal roofRooflasts 40–80 yrs≈2 lifetimes

Typical lives from InterNACHI Standard Estimated Life Expectancy Chart for Homes, CPSC, U.S. Department of Energy (hosted guide), US Department of Energy, Energy Saver Guide (2022), InterNACHI, Smoke Alarm Inspection, US EPA, New Homebuyer's Guide to Septic Systems, InterNACHI and U.S. Consumer Product Safety Commission. Real lives vary with climate, quality and upkeep.

Your place

Add a ZIP code for a few sourced facts about where the house stands: the homes around it, radon, climate and flood maps. All optional.

Looking up a ZIP code needs JavaScript. Everything else on this page works without it.

Part two

The year in context

What was changing around 1887, how much the country was building, how houses of this era stand today and what homes were like then. All of it describes houses in general, never this one.

The year in context · events

Around 1887: what was changing in homebuilding

The nearest dated events within 3 years either side, then longer changes 1887 falls inside. Each comes with its source and how strong that source is.

6 events on a 1883–1891 axis; the tagged line is 1887. Dashed rings are approximate (circa). Dashed lines below began earlier and run through the whole window.

Nothing in our timeline is dated to 1887 itself.

Nearby, 1889 to 1890within 3 years of 1887

  1. 1889circa

    Plumbing

    Automatic storage-tank gas water heater invented

    The first automatic, storage tank-type gas water heater was invented around 1889. Hot water on demand from a tank was therefore not a feature of houses much before the 1890s, and most older houses had it added later.

    WikipediaReference
    Quote
    “The first automatic, storage tank-type gas water heater was invented around 1889 by Ruud” Wikipedia
  2. 1890

    Electrical

    Fuse patented for electric distribution

    WikipediaReference
  3. 1890circa

    Materials

    Machine-made wire nails replace cut nails

    Round machine-made wire nails came into use around 1890 and are the nails found in houses built after that, replacing the square cut nails of earlier decades.

    InterNACHITrade reference
    Quote
    “Wire nails, used from 1890 through today” InterNACHI
  4. 1890circa

    Materials

    Sackett Board, the ancestor of drywall

    Sackett Board, plaster layered between sheets of felt paper, was invented around 1890 and is the forerunner of modern gypsum wallboard. It was not yet the normal way to finish a wall; plaster on lath was.

    WikipediaReference
    Quote
    “Sackett Board was invented in 1890 by New York Coal Tar Chemical Company employees Augustine Sackett and Fred L. Kane” Wikipedia

Under way in 1887long-running

  1. 1880–1940

    Electrical

    Knob-and-tube wiring is the standard wiring method

    InterNACHITrade referenceWikipediaReference
  2. 1880–1950

    Heating & cooling

    Gravity warm-air furnaces installed

    InterNACHITrade reference

Events come from a researched timeline of 150 dated changes to US homebuilding, each checked against the quoted source. Primary source is a government or standards body, Trade reference a trade body and Reference a general reference such as Wikipedia. A date is when something began or became required, not when every builder followed.

The year in context · building

Housing that year

How many new homes were started across the US in 1887, against every year since 1889. It is the whole country’s building, houses and apartments, not a count of houses like this one.

New homes started · 1887 · US

The national count of new homes starts in 1889, so there is no figure for 1887.

Started
no figure
  • Before 1959 the counts are historical estimates: Historical Statistics of the United States reconstructed them from building permits and other records, in series that change method in 1920, 1930 and 1945. They leave out farm housing. The figures here were transcribed by hand from a scanned copy and checked against the table’s own totals.
  • From 1959 the count is the Census Bureau’s privately owned housing units started; public housing is not in it. Mobile homes, conversions and temporary units are never counted.

Source US Census Bureau, Historical Statistics of the United States, Colonial Times to 1970, Series N 156 (1889–1958); New Residential Construction, annual housing starts (1959–2025).

As they stand today · houses built before 1920

Houses built before 1920, today

No survey recorded how new houses were built in 1887; the Census count starts in 1971. The closest view is the survivors: houses built before 1920 that are still standing and lived in, as they are now, after decades of new roofs, new siding and renovation. Not as they were built.

Showing the whole US · detached single-family houses

Region

Roofs today · built before 1950 · US

About 4 in 5 surviving houses built before 1950 across the US have asphalt shingle roofs today, and about 1 in 8 has a metal roof.

Roof material as reported in 2020. Most roofs have been replaced at least once since these houses were built, so this is what is on them now.

Homes sampled
1,946
Average size
2,102sq ft
  • Asphalt shingles78%
  • Metal12%
  • Wood shakes4%
  • Slate2%
  • Clay tile2%
  • Concrete tile1%
  • Other1%

1,946 homes sampled · EIA RECS 2020

Asphalt shingles, by era built

Roof, walls, window glass and stories come from the EIA survey, which can only group houses built before 1950. Everything else comes from the American Housing Survey’s finer band: houses built before 1920.

The shell

  1. Outside walls

    49% Siding: vinyl, aluminum, fiber cement or steel

    • Siding49%
    • Brick14%
    • Wood22%
    • Stucco9%
    • Stone2%
    • Concrete block2%
    • Other3%

    1,946 homes sampled · EIA RECS 2020

    Siding, by era built

  2. Window glass

    58% Double-pane

    • Single-pane41%
    • Double-pane58%
    • Triple-pane2%

    1,946 homes sampled · EIA RECS 2020

    Double-pane, by era built

  3. Foundation

    44% Full basement

    • Full basement44%
    • Part basement30%
    • Crawl space20%
    • Slab5%
    • Other2%

    1,634 homes sampled · AHS 2023

    Full basement, by era built

  4. Stories

    53% 2 stories

    • 1 story44%
    • 2 stories53%
    • 3 or more3%
    • Split-level1%

    1,946 homes sampled · EIA RECS 2020

    2 stories, by era built

Heating and cooling

  1. Main heating fuel

    54% Piped gas

    • Gas54%
    • Electricity17%
    • Oil13%
    • Propane9%
    • Wood5%
    • Other2%

    1,634 homes sampled · AHS 2023

    Piped gas, by era built

  2. Main heating equipment

    61% Forced warm-air furnace

    • Furnace61%
    • Boiler20%
    • Heat pump4%
    • Electric baseboard3%
    • Wall or room heater6%
    • Stove or fireplace4%
    • Other or none2%

    1,634 homes sampled · AHS 2023

    Forced warm-air furnace, by era built

  3. Air-conditioning

    45% Central air

    • Central air45%
    • Room units only39%
    • None16%

    1,634 homes sampled · AHS 2023

    Central air, by era built

The rooms

  1. Bathrooms

    34% One full bathroom

    • No full bath<0.5%
    • 134%
    • 1½20%
    • 227%
    • 2½10%
    • 3+9%

    1,634 homes sampled · AHS 2023

    One full bathroom, by era built

  2. Fireplace

    74% No usable fireplace

    • Usable fireplace26%
    • None74%

    1,634 homes sampled · AHS 2023

    No usable fireplace, by era built

  3. Size

    27% 1,000 to 1,499 sq ft

    • Under 1,0009%
    • 1,000–1,49927%
    • 1,500–1,99923%
    • 2,000–2,49918%
    • 2,500+24%

    1,490 homes sampled · AHS 2023

    1,000 to 1,499 sq ft, by era built

  4. Garage or carport

    66% Garage or carport

    • Garage or carport66%
    • Neither34%

    1,616 homes sampled · AHS 2023

    Garage or carport, by era built

  • Surviving detached single-family houses as they are today, by the decade their occupants say they were built. Roofs, siding, windows and heating include every replacement since. Houses that were torn down are not in it, so this is not how the era built.
  • In the Census Bureau’s words, “some of the home characteristics … may have been more recent additions or installations and did not come with the home when it was originally built.”
  • Survey estimates from samples of homes: a band with fewer than 30 sampled homes is never shown, and one with fewer than 100 is marked small sample. The EIA survey covers occupied primary homes only; the American Housing Survey also counts vacant ones.

Source US Energy Information Administration, Residential Energy Consumption Survey 2020, public microdata (roof, walls, window glass, stories, size); US Census Bureau and HUD, American Housing Survey 2023, national public use file (everything else); shares computed from the public microdata with the surveys’ weights. Caveat quoted from Census working paper 2011-18.

The year in context · the country

The country in 1940

The 1940 census was the earliest national count of housing, so it is the nearest look at the homes of 1887’s world, 53 years on. These describe every home standing at the time, old and new, not houses built that year.

Housing facts from the 1940 census, the US
FactUS
Lacking complete plumbinghot and cold piped water, a bathtub or shower, and a flush toiletCensus, plumbing45.3%
Main house heating fuelsgas includes bottled gas; electricity was not tabulatedCensus, house heating fuelcoal or coke 54.7%wood 22.8%utility gas 11.3%oil or kerosene 10.0%
No flush toiletCensus, sewage disposal35.3%
Homes owned by the people living in them, 1900Census, homeownership46.5%
Homes built in 1939 or earlier still standing todaythe survey groups everything before 1940ACS 2020-2024, B2503416.9 million 11.7% of homes
Half of all homes standing today were built beforethe median year builtACS 2020-2024, B250351980
Homes in 1950 that had been built in 1919 or earlierhow much of the 1950 stock came from this house’s years1950 Census of Housing45.8%

Census figures are shares of homes counted in 1940. Until 1990 plumbing counted as complete only when the household had it to itself. Today’s count is the US Census Bureau’s American Community Survey, 2020 to 2024, which includes vacant homes and dates them by what residents report. Choose your state above to see it beside the US.

See something in the 1887 report that looks wrong?Report an error on this page