Headline findingCheck first

Polybutylene water pipes

1978–1997 · 1988 is in the peak yearsApproximate era: Dates are an approximate era drawn from trade and reference sources.

Gray plastic polybutylene pipe, stamped PB2110, went into houses from 1978 to the mid-1990s, and its failures led to a class action settled for about $1 billion.

Polybutylene water pipes: 1978–1997; the line is 1988.

29 things on record apply to a 1988 house: 6 to check first, 9 protections it was built without, and 15 more by part of the house.

Where 1988 sits among every issue on record

Point at a band to read it · drag or use the arrow keys to compare years
What the 1988 line crosses29 bands
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

Check these first

The 6 items most worth a look in a 1988 house: safety first, then cost.

  1. Check firstOften present

    Polybutylene water pipes

    Gray plastic polybutylene pipe, stamped PB2110, went into houses from 1978 to the mid-1990s, and its failures led to a class action settled for about $1 billion.

    How to checkWater pipes · Water heater · Kitchen · Bathroom
    1. Look at the pipes entering the water heater, under sinks, at the main shut-off and at the meter.
    2. Polybutylene is flexible, 1/2 to 1 inch across, usually gray (sometimes blue outdoors, black or silver), and stamped 'PB2110'.
    3. Fittings are gray or white plastic, or copper or brass with aluminum or copper crimp rings.
    4. Do not confuse it with PEX (white, red or blue, stamped PEX) or CPVC (rigid and cream-colored).

    If you find itTalk to a plumber about repiping in PEX or copper, the standard recommendation. The Cox v. Shell settlement covered claims filed through May 2009, so that claim window has closed. Check with your insurer, since InterNACHI notes some owners face higher premiums or are refused coverage.

    How commonInterNACHI says polybutylene was installed in up to 10 million US homes. No source gives the share of houses of the era.

    Keep in mindPolybutylene went into several million US and Canadian homes from about 1978 into the 1990s, and sources put the end anywhere from mid-1995 to 1997, so a few later houses are possible. Many polybutylene systems have already been replaced.

    Details and 5 sources →

    1978–19971988 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.Possible
  2. Check firstOften presentCA ID MT OR +1

    Cadet and Encore wall heaters

    More than 1.9 million Cadet and Encore in-wall electric heaters, sold mainly in the Northwest and California from about 1978 to 2000, were recalled as a fire hazard.

    How to checkWalls, ceilings & floors · Heating & cooling
    1. Look through the grille of each electric wall heater for the label on the front of the heater assembly; do not take anything apart.
    2. Recalled models start with FW, FX, LX, TK, ZA, Z, RA, RK, RLX, RX, RW or ZC followed by three digits.
    3. The brand will be Cadet or Encore.

    If you find itStop using any recalled heater and replace it with a current model. The recall remedy was not found to be still running, so contact Cadet to ask before paying for replacements.

    How commonCPSC: more than 1.9 million units, concentrated in five states. No figure gives the share of houses; it applies mainly to houses with electric wall heat.

    Keep in mindCPSC gives the sale years only as 'about' 1978 through 2000, and only the listed model prefixes are affected. Heaters were also fitted as replacements in older houses.

    Details and 7 sources →

    1978–2000

    Court record: Dates come from a court settlement or a product recall.Possible
  3. Check firstOften presentCA

    Consolidated (Premier) attic furnaces

    Between 1983 and 1994, Consolidated Industries built well over 100,000 horizontal furnaces for California homes under many brand names, and CPSC tied them to about 50 fires.

    How to checkAttic · Heating & cooling
    1. Look at the furnace in the attic or crawl space for steel rods mounted above the burners (the 'NOx rods'), without removing any panels, or ask a heating contractor to check; every one of these furnaces has them.
    2. Check the label for Consolidated, Premier, Addison or Weatherking, or private labels including Amana, Bard, Carrier, Goettl, Goodman, Janitrol, Comfort-Aire, Trane and American Standard.
    3. CPSC's notice lists the affected model numbers.

    If you find itIf you find one, replace the furnace; the maker is gone and no recall remedy remains. Until then, CPSC advised having it serviced at least once a year and putting an ionization-type smoke alarm in the attic for early warning.

    How commonCPSC put production at about 140,000 units (2001) or 190,000 (2000), all for California, with about 50 fires reported. Most are now past normal furnace life, and no count of survivors exists.

    Keep in mindThese furnaces went only to California, and most furnaces of these years are other makes. A replacement furnace installed in an older house during these years could also be one.

    Details and 6 sources →

    1983–1994

    Court record: Dates come from a court settlement or a product recall.Rare
  4. Check firstOften present

    Federal Pacific Stab-Lok panels

    Federal Pacific Stab-Lok breaker panels were made from 1950 to 1980, and CPSC's own testing found breakers that failed calibration tests.

    How to checkElectrical panel
    1. Open the panel door (not the inner cover) and read the label for 'Federal Pacific Electric', 'FPE' or 'Federal Pioneer'.
    2. Look for 'Stab-Lok' printed on or near the breakers.
    3. Breaker handles often have a red or orange stripe across the tip.

    If you find itHave a licensed electrician inspect it. Replacing the whole panel is the usual fix. There was never a recall, so there is no manufacturer remedy.

    How commonNo reliable count exists. Claims of 'millions of homes' come from advocacy sources, and no market-share data was found.

    Keep in mindCPSC closed its investigation without a finding either way, saying it had too little data to accept or refute the maker's position. The widely quoted failure rates come from independent testing that could not be checked, and the production years come from a reference source, not from CPSC.

    Details and 6 sources →

    1950–1990most likely 1955–1980

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists
  5. Check firstBuilt without

    Missing or outdated smoke alarms

    Model building codes began requiring smoke alarms in every bedroom, linked so one sets off the rest, in 1988, so many older houses were built with far fewer.

    How to checkWhole house
    1. Count them: one in each bedroom, one outside each sleeping area, and one on every level including the basement.
    2. Press TEST on one: if all of them sound, they are interconnected.
    3. Twist one off its base: a wiring plug behind it means hard-wired; none means battery-only.
    4. Check the manufacture date on the back; over 10 years old means replace it.

    If you find itAdd alarms to every bedroom, hallway and level, using interconnected units; wireless interconnected alarms avoid new wiring. Replace any alarm over 10 years old.

    How commonNo reliable count exists of houses with alarms in every bedroom. NIST: the share of homes with at least one smoke alarm rose from 10% in 1975 to at least 92% by 2000.

    Keep in mindThe code dates come from reference sources and varied by code family and local adoption, so 1988 to 1993 is a transition and later is possible. Many older houses have been upgraded since.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 5 sources →

    Built 1995 or earliermost likely up to 1987

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists
  6. Check firstOften present

    Vermiculite attic insulation

    Loose, pebbly vermiculite insulation in the attic, often sold as Zonolite, may contain asbestos, and EPA advises treating it as if it does.

    How to checkAttic
    1. Look into the attic from the hatch without stepping in or disturbing anything.
    2. Vermiculite is loose, lightweight granules about 1/8 to 1/2 inch, shiny and accordion-like, gray-brown to silver-gold, lying between the joists.
    3. It is often under newer fiberglass or cellulose. InterNACHI tells inspectors that empty Zonolite bags left in the attic are a clue.
    4. EPA advises against relying on a negative lab test.

    If you find itLeave it undisturbed, keep boxes and other stored items out of that attic, and do not try to remove it yourself. EPA advises hiring a professional asbestos contractor before any remodeling that would disturb it. Zonolite Attic Insulation claims against W.R. Grace were settled in its bankruptcy; this guide could not confirm whether any reimbursement is still offered.

    How commonWikipedia reports a US government estimate that vermiculite was used in more than 35 million homes; other estimates are far lower. Even the high figure is a minority of houses.

    Keep in mindThis was largely a do-it-yourself product added to existing houses, so build year is a weak guide. Most houses do not have it, and estimates of how many do disagree widely.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 10 sources →

    Built 1990 or earlier

    Approximate era: Dates are an approximate era drawn from trade and reference sources.Possible

Built without

Protections that became standard after 1988. A house keeps what it was built with unless someone added them, and many have been.

  • Garage door opener without auto-reverse

    Built 1992 or earlier · peakGarage door openers made before 1991 did not have to reverse when they hit something, and photo-eyes or similar protection became required on openers made from 1993.

    Garage door openers made before 1991 did not have to reverse when they hit something, and photo-eyes or similar protection became required on openers made from 1993.

    Read the full entry →

    Built 1992 or earlier1988 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look for two small sensor 'eyes' near the floor on each side of the garage door opening.
    2. Check the date on the opener's label.
    3. Test it: lay a 2x4 flat on the floor under the door; the door should reverse when it touches the board.

    If you find itIf the opener does not reverse or has no sensors, replace it with a current UL 325-compliant unit rather than trying to retrofit it. Until then, keep children clear of the door while it moves.

    How commonNo reliable count exists of pre-1993 openers still in use.

    Keep in mindThe 1993 rule can be met by a constant-contact wall button instead of photo-eyes, so a newer opener without eyes is possible. Openers are often added or replaced long after a house is built.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →
  • Florida home built before the statewide wind code

    Built 2002 or earlierFLFlorida homes built before the statewide Florida Building Code took effect on March 1, 2002 were built to earlier local codes; the statewide code followed Hurricane Andrew.

    Florida homes built before the statewide Florida Building Code took effect on March 1, 2002 were built to earlier local codes; the statewide code followed Hurricane Andrew.

    Read the full entry →

    Built 2002 or earlier

    Approximate era: Dates are an approximate era drawn from trade and reference sources.Likely

    How to check

    1. In the attic at the eaves, look where each truss or rafter meets the top of the wall.
    2. Only angled nails means toe-nailed; a small metal bracket is a clip; a metal strap wrapping over the truss is a wrap, and two straps a double wrap.
    3. Check windows and doors for impact-rated labels or shutter hardware.
    4. Your county permit record gives the original permit date.

    If you find itGet a wind-mitigation inspection by a licensed inspector; it records these features for your insurer. Upgrades such as roof-to-wall straps, re-nailing the roof deck and shutters are usually done at re-roofing time.

    How commonWikipedia puts the number of Florida homes that predate the modern code at about 4.7 million; every Florida home built before March 2002 predates it.

    Keep in mindHouses finished around 2002 can go either way, depending on when they were approved. In South Florida's High-Velocity Hurricane Zones the stricter code dates from 1994. Some pre-2002 homes do have clips or straps.

    Details and 4 sources →
  • Gas water heaters made before 2003 (no flammable-vapor protection)

    Built 2003 or earlierStandard gas tank water heaters made after July 1, 2003 are built to resist igniting gasoline fumes; older ones are not.

    Standard gas tank water heaters made after July 1, 2003 are built to resist igniting gasoline fumes; older ones are not.

    Read the full entry →

    Built 2003 or earlier

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Check whether the water heater is a gas tank model (a burner at the bottom and a vent pipe on top).
    2. Read the label for the words 'Flammable Vapor Ignition Resistant' or 'FVIR'.
    3. Look for the manufacture date in the label or serial number: after July 2003 means it should have the protection.
    4. Notice whether gasoline, paint thinner or solvents are stored near it, especially in a garage.

    If you find itKeep gasoline and solvents well away from any gas appliance. If the heater predates the standard, plan to replace it with a current model.

    How commonAny gas tank heater made before July 2003 lacks it. Many heaters that old have been replaced; no count of how many remain exists.

    Keep in mindThis was a voluntary industry standard, not a federal law, and it covers standard 30, 40 and 50 gallon gas tank heaters. Water heaters are replaced often, so the heater's own date matters far more than the house's.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →
  • Missing GFCI shock protection

    Built 1992 or earlierCPSC says houses built before 1973 have no GFCI shock protection unless it was added later, and the code then added it one area at a time: bathrooms in 1975, garages in 1978, some kitchen outlets in 1987.

    CPSC says houses built before 1973 have no GFCI shock protection unless it was added later, and the code then added it one area at a time: bathrooms in 1975, garages in 1978, some kitchen outlets in 1987.

    Read the full entry →

    Built 1992 or earliermost likely up to 1972

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look for outlets with TEST and RESET buttons in bathrooms, at kitchen counters, in the garage, outdoors, in the basement and in the laundry.
    2. Check the panel for breakers with a test button; a GFCI breaker protects a whole circuit.
    3. One GFCI can protect ordinary-looking outlets further along the circuit: press TEST and see which outlets go dead.
    4. Press RESET afterwards. A GFCI that does not trip when you press TEST needs replacing.

    If you find itAn electrician can add GFCI outlets or breakers where they are missing; they are allowed on ungrounded circuits too. Replace any GFCI that does not trip when tested.

    How commonNo reliable count exists on how many older houses have had GFCIs added. CPSC notes that houses built before 1973 have no GFCI protection unless it was installed later.

    Keep in mindThese are national code edition years. States and cities adopted each edition anywhere from the same year to several years later, so a house built just after a milestone may not have that protection. Many older houses have had GFCIs added since, so build year is only a rough guide.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →
  • No arc-fault (AFCI) breakers

    Built 2004 or earlier · peakArc-fault breakers, which detect the sparking that can start wiring fires, were first required in bedrooms of new houses in 2002.

    Arc-fault breakers, which detect the sparking that can start wiring fires, were first required in bedrooms of new houses in 2002.

    Read the full entry →

    Built 2004 or earlier1988 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Open the panel door and look for breakers with a TEST button labeled AFCI, 'Arc Fault', 'Combination AFCI' or 'Dual Function'.
    2. Ordinary breakers have no test button.

    If you find itThis is an optional upgrade: an electrician can fit AFCI or dual-function breakers where your panel supports them.

    How commonNo reliable count exists. Houses built before about 2002 will lack AFCIs unless they were added later.

    Keep in mindStates adopt each code edition on their own schedule, so build year is a weak guide on its own. Only the 2002 bedroom date is confirmed by a primary source.

    Details and 2 sources →
  • Outlets without child-safety shutters

    Built 2010 or earlier · peakSince the 2008 electrical code, new houses get outlets with built-in shutters that stop a child pushing a key or hairpin into the slot.

    Since the 2008 electrical code, new houses get outlets with built-in shutters that stop a child pushing a key or hairpin into the slot.

    Read the full entry →

    Built 2010 or earlier1988 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look closely at an outlet: 'TR' embossed on the face between the slots means tamper-resistant.
    2. You can see plastic shutters inside the slots.

    If you find itIf small children live in or visit the house, have outlets replaced with TR-listed ones.

    How commonNo reliable count exists. Houses built before their state adopted the 2008 code will generally lack them unless outlets were replaced.

    Keep in mind2008 is the model code year; states adopted it at different times. As of 2016, the rule did not apply to manufactured homes.

    Details and 3 sources →
  • Manufactured home built before 1994 wind standards

    Built 1994 or earlierAfter Hurricane Andrew, HUD raised the wind standards for manufactured homes made from July 13, 1994, with zones designed for 100 and 110 mph winds.

    After Hurricane Andrew, HUD raised the wind standards for manufactured homes made from July 13, 1994, with zones designed for 100 and 110 mph winds.

    Read the full entry →

    Built 1994 or earlier

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Find the data plate inside the home, often in a kitchen cabinet, the electrical panel or a bedroom closet.
    2. Read the manufacture date and the wind-zone map showing which zone (I, II or III) the home was designed for.
    3. No wind-zone designation, or a date before July 1994, means the older standard.

    If you find itHave the anchoring and tie-downs checked and brought up to current installation standards. Only replacement gets you the post-1994 structural design.

    How commonNo reliable count exists. Every manufactured home made before the date was built to the older standard.

    Keep in mindDate of manufacture governs, not the year the home was placed. Exactly which counties fall in each wind zone was not confirmed; the higher zones cover the hurricane coast.

    Details and 2 sources →
  • Built before mandatory airtightness testing (2012 energy code)

    Built 2015 or earlierThe 2012 energy code was the first to make new houses pass a whole-house air leakage test.

    The 2012 energy code was the first to make new houses pass a whole-house air leakage test.

    Read the full entry →

    Built 2015 or earlier

    Federal rule: Dates come from a federal rule or a model building code.Likely

    How to check

    1. Look near the electrical panel or furnace for an energy code certificate or a posted blower-door test result.
    2. Ask the seller or builder whether a blower-door test or energy rating was done.
    3. Notice drafts around outlets, attic hatches, recessed lights and window trim on a cold or windy day.

    If you find itNothing is required. If the house feels drafty or bills are high, an energy audit with a blower-door test shows where air sealing would help most.

    How commonHouses built before their state adopted the 2012 code were not required to pass this test. Adoption dates by state were not researched.

    Keep in mindThis is a model code. States and cities adopted it at different times, so the end year here is stretched a few years and is soft. Check your state's adoption date.

    Details and 3 sources →

Everything else, by part of the house

Materials and products often installed in 1988. Open any row for how to check.

Where to look. Each number counts the items in this report for that part of the house.

Electrical1

  • Challenger breaker panels

    1978–1994 · peakChallenger panels, the successor to the Zinsco line, were sold from 1978 to 1994, and one batch of their GFCI breakers was recalled in 1988.

    Challenger panels, the successor to the Zinsco line, were sold from 1978 to 1994, and one batch of their GFCI breakers was recalled in 1988.

    Read the full entry →

    1978–19941988 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Look for 'Challenger' embossed on the panel door handle or printed on the label inside the door.
    2. Look for 15- or 20-amp breakers with a test button marked HAGF-15 or HAGF-20; those are the recalled types.

    If you find itHave an electrician check the panel for heat damage and for HAGF breakers. If either turns up, or your insurer asks, replacing the panel is the usual route.

    How commonNo reliable count exists. The 1988 recall covered about 9,000 breakers.

    Keep in mindPanels labeled Challenger from 1978 to about 1981 are Zinsco-design panels. Production years come from one reference article, and the recall covered only breakers made in a two-month window in 1988.

    Details and 6 sources →

Plumbing & water1

  • Lead solder in copper water pipes

    1930–1988Copper water pipes installed before mid-1986 were commonly joined with lead solder, and EPA says solder and old brass fixtures are the most common lead source in homes without a lead service line.

    Copper water pipes installed before mid-1986 were commonly joined with lead solder, and EPA says solder and old brass fixtures are the most common lead source in homes without a lead service line.

    Read the full entry →

    1930–1988most likely up to 1986

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look at exposed copper pipe joints in the basement, at the water heater or under sinks. Old lead solder is dull gray and lead-free solder is brighter silver, but age blurs the difference.
    2. A lead swab test kit on a cleaned joint gives a better answer.
    3. The most reliable check is a first-draw water test through your utility or a certified lab.

    If you find itTest your water. If lead shows up, run the cold tap before drinking, use cold water for cooking, and use a filter certified to NSF/ANSI 53 for lead. Replacing old brass faucets with post-2014 ones helps; repiping for solder alone is rarely needed.

    How commonNo reliable count exists of how many houses built before the ban still have lead-solder joints.

    Keep in mindThe federal ban took effect in June 1986, but states had until June 1988 to enforce it, so houses built from 1986 to 1988 are a gray zone. Copper has been used since the 1930s, and many older houses have been partly or fully repiped.

    Details and 8 sources →

Kitchen & bath2

  • Kidde plastic-handle fire extinguishers (2017 recall)

    1973–2017Kidde recalled about 37.8 million fire extinguishers because some may not spray when you need them.

    Kidde recalled about 37.8 million fire extinguishers because some may not spray when you need them.

    Read the full entry →

    1973–2017

    Court record: Dates come from a court settlement or a product recall.No reliable count exists

    How to check

    1. Look under the kitchen sink, in the pantry, garage and utility room for any Kidde extinguisher.
    2. Note whether it has a plastic handle (red, white or silver models) or a push-button Pindicator top.
    3. Read the model number on the label and compare it with the model list on the CPSC recall notice.
    4. On units made in 2007 or later, a 10-digit date code is printed on the side of the cylinder near the bottom.

    If you find itIf the model is on the list, replace it and contact Kidde through the product safety recall page on kidde.com. Check the recall notice for whether the replacement offer is still open.

    How commonAbout 37.8 million units were recalled in the US; no count of affected homes exists.

    Keep in mindExtinguishers are bought, not built in, so the year a house was built predicts little: owners add them to houses of every age. The recall did not cover every Kidde extinguisher, only the listed models.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →
  • High-flow toilets and showerheads

    Built 1993 or earlierSince 1994, new toilets can use only 1.6 gallons per flush, less than half the water of most models in use before then.

    Since 1994, new toilets can use only 1.6 gallons per flush, less than half the water of most models in use before then.

    Read the full entry →

    Built 1993 or earlier

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Lift the toilet tank lid: the gallons per flush is usually stamped or printed inside the tank, or on the bowl behind the seat, with a manufacture date.
    2. '1.6 gpf / 6.0 Lpf' or lower means it meets the 1994 rule.
    3. No marking and a large tank suggest a pre-1994 toilet.

    If you find itIf you want lower water bills, replace with a WaterSense-labeled toilet and showerhead, and check whether your utility offers a rebate.

    How commonNo reliable count exists. Toilets and showerheads are replaced often, so many older houses already have newer ones.

    Keep in mindThe rule applied to fixtures made from January 1, 1994, so houses finished in 1994 may still have older stock. Fixtures are swapped so often that build year predicts this poorly.

    Details and 3 sources →

Heating, cooling & chimney2

  • Plexvent and Ultravent plastic flue pipe

    1988–1994About 250,000 gas furnaces and boilers were vented through gray or black plastic pipe printed Plexvent or Ultravent, which was recalled because joints can crack or separate and leak carbon monoxide.

    About 250,000 gas furnaces and boilers were vented through gray or black plastic pipe printed Plexvent or Ultravent, which was recalled because joints can crack or separate and leak carbon monoxide.

    Read the full entry →

    1988–1994

    Court record: Dates come from a court settlement or a product recall.Rare

    How to check

    1. Follow the flue pipe from the furnace or boiler to where it leaves the house, usually through a side wall.
    2. Gray or black plastic pipe printed 'Plexvent', 'Plexvent II' or 'Ultravent' is the recalled type.
    3. White PVC or CPVC pipe is not part of the recall.

    If you find itHave a heating contractor inspect it promptly. At this age, replacing the vent along with the appliance is often the realistic fix. Whether any recall remedy is still honored is unknown.

    How commonCPSC: about 250,000 systems nationally, about 93,000 of them replaced by October 2005.

    Keep in mindThe full date range of these vents was never published; 1988 to 1994 comes from one subset. Many have already been replaced along with their furnaces.

    Details and 4 sources →
  • R-22 (Freon) air conditioner

    Built 2009 or earlierSince January 1, 2010, EPA has barred making new air conditioners or pre-charged parts with R-22, and US production and import of the refrigerant ended in 2020.

    Since January 1, 2010, EPA has barred making new air conditioners or pre-charged parts with R-22, and US production and import of the refrigerant ended in 2020.

    Read the full entry →

    Built 2009 or earlier

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Read the data plate on the outdoor unit: 'R-22' or 'HCFC-22' means the old refrigerant; newer units say R-410A, R-454B or R-32.
    2. The manufacture date is usually on the same plate.

    If you find itNothing to do while it works. Budget for replacing the outdoor unit and indoor coil together when it fails.

    How commonNo reliable count exists of pre-2010 units still in service.

    Keep in mindAir conditioning is often added or replaced long after a house is built, so the unit's age matters far more than the house's.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 5 sources →

Roof & attic2

  • CertainTeed organic shingles

    1987–2006CertainTeed estimated that about 1.86 million buildings got its felt-based organic shingles between 1987 and 2005, and a class settlement followed.

    CertainTeed estimated that about 1.86 million buildings got its felt-based organic shingles between 1987 and 2005, and a class settlement followed.

    Read the full entry →

    1987–2006

    Court record: Dates come from a court settlement or a product recall.Rare

    How to check

    1. Look for CertainTeed wrappers, invoices or warranty papers and check whether they describe an organic (felt) shingle rather than fiberglass.
    2. A torn shingle shows a brown or black felt core rather than white glass fibers.
    3. Heavy curling at tab corners and blistering on an old roof are typical of organic shingles.

    If you find itIf the roof is failing, re-roof. Contact CertainTeed to ask whether claims are still possible; the claim deadline could not be confirmed.

    How commonCertainTeed's own estimate in court: about 1,857,000 structures were built with these shingles from 1987 to 2005, a small share of roofs laid in those years.

    Keep in mindMany roofs from this period have already been replaced, and the older the house, the less likely the original roof survives. Installation could trail manufacture by a year or so.

    Details and 3 sources →
  • Factory-built roof trusses

    Built 1955 or laterIf your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.

    If your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.

    Read the full entry →

    Built 1955 or later

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. In the attic, look for diagonal 2x4s forming W or M shapes, joined by toothed galvanized steel plates.
    2. Rafters, by contrast, are larger boards running from the ridge to the wall with open space between.
    3. Look for cut or notched members and plates that have backed out of the wood.

    If you find itNothing is needed unless trusses are damaged or altered. Before any attic conversion, skylight or other change that touches a truss, get an engineer's design.

    How commonNo reliable count exists for houses by year built.

    Keep in mindTruss use grew over decades, and many houses still use rafters, especially custom homes and complex roofs. A reference source dates the connector plate to 1955.

    Details and 1 source →

Exterior walls & windows3

  • Synthetic stucco (barrier EIFS)

    1980–1999 · peakSynthetic stucco over wood framing sounds hollow when you knock on it, and the early 'barrier' kind could trap water and rot the wall behind.

    Synthetic stucco over wood framing sounds hollow when you knock on it, and the early 'barrier' kind could trap water and rot the wall behind.

    Read the full entry →

    1980–19991988 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.Rare

    How to check

    1. Knock on or press the wall: synthetic stucco sounds hollow and gives slightly, while traditional stucco is hard.
    2. Look for foam showing at a damaged spot or at the bottom edge, and for finish running right down to or below the ground.
    3. Look for staining below window corners and where decks or roofs meet the wall.

    If you find itBefore buying, or if you see stains, get a moisture-probe inspection by a certified EIFS inspector. Dry walls may need only flashing and sealant work; wet walls may need stripping and re-cladding with a drained system.

    How commonEIFS was about 4% of the US residential siding market in 1997 (Wikipedia, citing a trade source).

    Keep in mindStart and end years are approximate, and the move to drainable EIFS did not happen everywhere at the same time.

    Details and 4 sources →
  • Hardboard siding (Masonite and others)

    1980–1998Hardboard siding swells and rots when water gets in, and in 1996 a jury found Masonite's siding defective.

    Hardboard siding swells and rots when water gets in, and in 1996 a jury found Masonite's siding defective.

    Read the full entry →

    1980–1998

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Look at cut ends or where paint has failed: smooth or embossed board of uniform brown fiber, with no visible strands or plies.
    2. Check bottom edges, butt joints and around nails for swelling, 'mushroomed' nail heads and soft spots.

    If you find itKeep paint and caulk in good shape, replace damaged boards, or re-side when damage spreads. No open claim program was found.

    How commonNo reliable count exists, and no confirmed figure for the size of the Masonite class was found.

    Keep in mindThe 1980 to 1998 range is the reported Masonite class window, which could not be confirmed, and hardboard was used before 1980 too. Brands look alike, so the maker is hard to tell from the outside.

    Details and 2 sources →
  • LP Inner-Seal siding

    1985–1995Louisiana-Pacific's Inner-Seal siding, marketed from 1985, swelled and rotted on enough houses to bring a class settlement covering everything installed before 1996.

    Louisiana-Pacific's Inner-Seal siding, marketed from 1985, swelled and rotted on enough houses to bring a class settlement covering everything installed before 1996.

    Read the full entry →

    1985–1995

    Court record: Dates come from a court settlement or a product recall.No reliable count exists

    How to check

    1. Look at a cut end or the bottom drip edge of the siding: visible wood flakes or strands mean OSB (hardboard shows uniform fiber instead).
    2. Check bottom edges and around nail heads for swelling, crumbling and 'mushrooming'.

    If you find itKeep paint and caulk intact, replace failed boards, and plan to re-side if damage is widespread. The settlement required claims to be filed before January 1, 2003.

    How commonNo reliable count exists. The often-repeated figure of 800,000 homes could not be confirmed.

    Keep in mindThe 1985 start rests on a reference source. Many installs have already been replaced, and this was one brand among many sidings of the era.

    Details and 2 sources →

Foundation & basement3

  • Crumbling concrete foundations (pyrrhotite)

    1983–2015CT MAIn parts of north-central Connecticut and central Massachusetts, some foundations poured with local quarry stone are crumbling because of a mineral called pyrrhotite.

    In parts of north-central Connecticut and central Massachusetts, some foundations poured with local quarry stone are crumbling because of a mineral called pyrrhotite.

    Read the full entry →

    1983–2015

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. In the basement, look at the foundation walls for horizontal cracks and map-pattern (spider-web) cracking.
    2. Look for white powdery deposits, rust-brown staining and flaking.
    3. A clean-looking wall does not rule it out; a licensed engineer's visual inspection and a core sample tested for pyrrhotite confirm it.

    If you find itIf you are in an affected area, have a licensed engineer inspect the foundation, especially before buying, and check with your state about any current testing or repair assistance.

    How commonNo reliable count exists. The problem is tied to aggregate from certain local quarries, so it is limited to parts of central Connecticut and Massachusetts.

    Keep in mindThe 1983 to 2015 window comes from state officials' figures that could not be independently confirmed, and only towns near the source quarries are affected. Most houses in Connecticut and Massachusetts are not at risk.

    Details and 2 sources →
  • Chlordane termite treatment

    1948–1988From 1948 to 1988, chlordane was used in the US as a pesticide, including against termites around houses, and ATSDR says more than 50 million people have lived in treated homes.

    From 1948 to 1988, chlordane was used in the US as a pesticide, including against termites around houses, and ATSDR says more than 50 million people have lived in treated homes.

    Read the full entry →

    1948–1988

    Federal rule: Dates come from a federal rule or a model building code.Possible

    How to check

    1. There is no visible sign. Look for old termite-treatment records or pest-control stickers.
    2. Look for patched drill holes in the slab, garage floor or along the foundation walls.
    3. Only an indoor air or soil lab test confirms it.

    If you find itIf you are concerned, test the indoor air. Seal slab cracks and crawl-space and duct leaks, ventilate basements and crawl spaces, and avoid growing food crops right beside the foundation.

    How commonATSDR: over 50 million people have lived in chlordane-treated homes; Wikipedia puts it at about 30 million homes. Use was heaviest in the deep South and Southwest.

    Keep in mindTreatment was done both during construction and later on existing houses, so any house standing before 1988 in termite country may have been treated. Many houses never were.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 9 sources →
  • Engineered I-joist floors

    Built 1970 or laterBy 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.

    By 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.

    Read the full entry →

    Built 1970 or latermost likely from 2000

    Approximate era: Dates are an approximate era drawn from trade and reference sources.Possible

    How to check

    1. Look up at the basement or garage ceiling for I-shaped joists: a thin OSB or plywood web with small lumber flanges top and bottom.
    2. They are usually printed with the maker's brand name.
    3. If you can see them, they are unprotected from below.

    If you find itConsider covering exposed I-joists with drywall, and make sure working smoke alarms cover every level, including the basement.

    How commonWikipedia: about 50% of wood light-frame floors used I-joists as of 2005.

    Keep in mindNewer model codes are reported to require covering them, but that was not confirmed and code adoption varies by state. The hazard applies only where the joists are exposed.

    Details and 2 sources →

Garage, deck & yard1

  • Arsenic-treated (CCA) deck lumber

    1975–2004 · peakPressure-treated wood in decks and play sets built before 2004 was commonly treated with an arsenic compound, and EPA says never to burn it.

    Pressure-treated wood in decks and play sets built before 2004 was commonly treated with an arsenic compound, and EPA says never to burn it.

    Read the full entry →

    1975–20041988 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.No reliable count exists

    How to check

    1. Look at decks, play sets, fences and garden edging built of pressure-treated wood before 2004.
    2. End tags or ink stamps may read 'CCA' with a number such as 0.40; newer wood reads ACQ, CA or MCA.
    3. Arsenic swab test kits and lab tests exist.

    If you find itWash hands after contact, never burn the wood or use it for garden beds, and wear a mask when cutting it. Sealants may reduce surface arsenic, but CPSC testing found few held up after two years. Replace with alternative-treated wood or composite when the deck is due.

    How commonNo reliable count exists. EPA says CCA-treated wood was used in decks and playsets before 2004, but no market-share figure was found.

    Keep in mindAt manufacturers' request, EPA cancelled CCA for most residential wood, including decks, after December 30, 2003, but old stock could still be sold, so some decks built in 2004 may have used it. The 1975 start is approximate. Decks are often built or replaced long after the house, so the deck's age matters more than the house's.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 10 sources →

What’s due at this age

A 1988 house is 38 years old. Here is where its parts stand against their typical life, and which ones have certainly been replaced by now.

In their window
3
Past life, if original
4
Due within 5 yrs
4
Replaced by now
32

32 of the 53 parts we track wear out so much faster than a 1988 house has stood that they have been replaced at least once. Know when something was last replaced? Enter the year (or a decade, like 2010s) and we’ll show where that part stands. It stays on this device only.

First life ending around now

3

Long-lived parts installed in 1988 reach the end of their typical life about now. If they are original, these are the ones to look at and budget for.

  • Aluminum gutters and downspoutsRoof · lasts 20–40 yrs

    Sagging, leaking seams and water spilling over the edge are the signs. Failed gutters send water to the foundation.

    20–40 yrsIn its windowif original
  • Septic systemDrains & sewer · lasts 15–40 yrs

    Regular pumping and inspection extend life; the drainfield usually fails first. Slow drains, odors and wet or unusually green ground over the drainfield are the warning signs.

    15–40 yrsIn its windowif original
  • Vinyl or fiberglass windowsWindows · lasts 20–40 yrs

    Fogging between panes means the seal has failed. Warped frames and drafts are other signs.

    20–40 yrsIn its windowif original

Past typical life, if still original

4

Older than the usual range, but not so old that an original is unlikely. Worth finding out whether they have been replaced.

  • Asphalt shingle roof (architectural)Roof · lasts ~30 yrs
    ~30 yrs8 yrs pastif original
  • Deck framingDeck & yard · lasts 10–30 yrs
    10–30 yrs8 yrs pastif original
  • GFCI outletsKitchen · lasts ~30 yrs
    ~30 yrs8 yrs pastif original
  • Wood windowsWindows · lasts ~30 yrs
    ~30 yrs8 yrs pastif original

Coming due in the next five years

4

Not yet, but close enough to plan for.

  • Boiler (hot-water or steam)Heating & cooling · lasts ~40 yrs

    InterNACHI's chart puts boilers at about 40 years against 15 to 25 for furnaces. Leaks around the unit, rust and rising pressure problems suggest it is wearing out.

    ~40 yrsIn 2 yrsif original
  • Chimney flue tileChimney · lasts 40–120 yrs

    CPSC says a fireplace can start a fire if the chimney is cracked, blocked or coated with creosote. It advises a professional inspection of chimneys, flues and vents every year, so have one done before using the fireplace in an older house.

    40–120 yrsIn 2 yrsif original
  • Concrete walkwayDeck & yard · lasts 40–50 yrs

    The chart lists walks, not driveways. Heaved or cracked slabs are a trip hazard worth fixing.

    40–50 yrsIn 2 yrsif original
  • Metal roofRoof · lasts 40–80 yrs

    Life depends on the metal and coating. Loose fasteners and flashing are usually what fail first, not the panels.

    40–80 yrsIn 2 yrsif original
Replaced at least once by now: find out when32

A 1988 house has outlasted these parts’ typical life at least once over, so what matters is when each was last replaced. Ask the seller or check receipts and date labels; enter a year and the part moves up to where it stands.

  • Carbon monoxide alarmWhole houselasts ~5 yrs≈7 lifetimes
  • Dryer vent (plastic)Whole houselasts ~5 yrs≈7 lifetimes
  • Sump pumpBasement & foundationlasts ~7 yrs≈5 lifetimes
  • DishwasherKitchenlasts ~9 yrs≈4 lifetimes
  • CarpetWalls, ceilings & floorslasts 8–10 yrs≈4 lifetimes
  • Caulking (interior and exterior)Exterior wallslasts 5–10 yrs≈5 lifetimes
  • Exterior paintExterior wallslasts 7–10 yrs≈4 lifetimes
  • Smoke alarmWhole houselasts ~10 yrs≈3 lifetimes
  • Garbage disposalKitchenlasts ~12 yrs≈3 lifetimes
  • Clothes dryerWhole houselasts ~13 yrs≈2 lifetimes
  • RefrigeratorKitchenlasts 9–13 yrs≈3 lifetimes
  • Central air conditionerHeating & coolinglasts 7–15 yrs≈3 lifetimes
  • Electric rangeKitchenlasts 13–15 yrs≈2 lifetimes
  • Garage door openerGaragelasts 10–15 yrs≈3 lifetimes
  • Heat pumpHeating & coolinglasts 10–15 yrs≈3 lifetimes
  • Tank water heaterWater heaterlasts 6–15 yrs≈3 lifetimes
  • Washing machineBathroomlasts 5–15 yrs≈3 lifetimes
  • Well pumpWater pipeslasts ~15 yrs≈2 lifetimes
  • Wood deck boardsDeck & yardlasts ~15 yrs≈2 lifetimes
  • Gas rangeKitchenlasts 15–17 yrs≈2 lifetimes
  • Aluminum windowsWindowslasts 15–20 yrs≈2 lifetimes
  • Asphalt drivewayDeck & yardlasts 15–20 yrs≈2 lifetimes
  • Asphalt shingle roof (3-tab)Rooflasts ~20 yrs≈1 lifetimes
  • Faucets and spray hoseBathroomlasts 15–20 yrs≈2 lifetimes
  • Flat roof (modified bitumen)Rooflasts ~20 yrs≈1 lifetimes
  • Tankless water heaterWater heaterlasts 10–20 yrs≈2 lifetimes
  • Water softenerWater pipeslasts ~20 yrs≈1 lifetimes
  • Flat roof (EPDM rubber)Rooflasts 15–25 yrs≈1 lifetimes
  • Forced-air furnaceHeating & coolinglasts 15–25 yrs≈1 lifetimes
  • Garage doorGaragelasts 20–25 yrs≈1 lifetimes
  • Vinyl floorWalls, ceilings & floorslasts ~25 yrs≈1 lifetimes
  • Wood shake roofRooflasts ~25 yrs≈1 lifetimes
Further out10
  • Cast-iron drain pipe (below ground)Drains & sewerlasts 50–60 yrsin 12 yrs
  • Copper water supply linesWater pipeslasts 50–70 yrsin 12 yrs
  • Electrical service panelElectrical panellasts ~60 yrsin 22 yrs
  • Heating and cooling ductworkHeating & coolinglasts 60–100 yrsin 22 yrs
  • Vinyl sidingExterior wallslasts ~60 yrsin 22 yrs
  • Clay or concrete tile roofRooflasts ~100 yrsin 62 yrs
  • Fiber cement sidingExterior wallslasts ~100 yrsin 62 yrs
  • Fiberglass exterior doorWhole houselasts ~100 yrsin 62 yrs
  • Hardwood floorWalls, ceilings & floorslasts ~100 yrsin 62 yrs
  • ToiletsBathroomlasts ~100 yrsin 62 yrs

Typical lives from InterNACHI Standard Estimated Life Expectancy Chart for Homes, CPSC, U.S. Department of Energy (hosted guide), US Department of Energy, Energy Saver Guide (2022), InterNACHI, Smoke Alarm Inspection, US EPA, New Homebuyer's Guide to Septic Systems, InterNACHI and U.S. Consumer Product Safety Commission. Real lives vary with climate, quality and upkeep.

Your place

Add a ZIP code for a few sourced facts about where the house stands: the homes around it, radon, climate and flood maps. All optional.

Looking up a ZIP code needs JavaScript. Everything else on this page works without it.

Part two

The year in context

What was changing around 1988, how much the country was building, how houses of this era stand today and what homes were like then. All of it describes houses in general, never this one.

The year in context · events

Around 1988: what was changing in homebuilding

What happened in 1988 first, then the nearest dated events within 2 years either side, then longer changes 1988 falls inside. Each comes with its source and how strong that source is.

8 events on a 1985–1991 axis; the tagged line is 1988. Filled rings are dated to 1988. Dashed rings are approximate (circa). Dashed lines below began earlier and run through the whole window.

In 1988

  1. 1988

    Hazardous materials

    EPA begins its radon program and the Indoor Radon Abatement Act passes

    Since 1988 EPA has run a voluntary program to reduce radon exposure under the Indoor Radon Abatement Act. There is no federal radon requirement for houses, so radon-resistant features in new houses are voluntary or set by local code.

    U.S. Environmental Protection AgencyPrimary source
    Quote
    “Since 1988, EPA has administered a voluntary program to reduce” U.S. Environmental Protection Agency
  2. 1988

    Plumbing

    Massachusetts first to mandate low-flush toilets

    In 1988 Massachusetts became the first state to require low-flush toilets in new construction and remodeling. Before the early 1990s standard US toilets typically used at least 3.5 gallons per flush.

    WikipediaReference
    Quote
    “In 1988, Massachusetts became the first state in the US to mandate the use of low-flush toilets in new construction and remodeling.” Wikipedia

Nearby, 1986 to 1990within 2 years of 1988

  1. 1986

    Plumbing

    Lead pipe, solder and flux banned in drinking-water plumbing

  2. 1987

    Electrical

    GFCI protection required at some kitchen receptacles

  3. 1989

    Hazardous materials

    EPA partial ban on asbestos products

    EPA issued a partial ban on the manufacture, import, processing and distribution of some asbestos products in 1989 and banned new uses. Many asbestos building products already existed, so house materials made around then may still contain it.

    U.S. Environmental Protection AgencyPrimary source
    Quote
    “1989 Partial Ban on the manufacture, import, processing, and distribution of some asbestos-containing products.” U.S. Environmental Protection Agency
  4. 1990

    Industry

    Typical new house in 1990

    In 1990, 76 percent of new single-family houses completed had air conditioning and the median house had 1,905 square feet.

    U.S. Census Bureau, Characteristics of New Housing 2017 (annual tables)Primary source
    Quotes
    “1990 966 731 235 100 76 24” U.S. Census Bureau, Characteristics of New Housing 2017 (annual tables)
    “1990 1,905 1,955 1,850 1,855 1,985 2,080 2,105 2,005 2,055 2,160” U.S. Census Bureau, Characteristics of New Housing 2017 (annual tables)

Under way in 1988long-running

  1. 1980–1989circa

    Electrical

    Receptacle-type GFCIs become common

    GFCIs built into the outlet receptacle became commonplace beginning in the 1980s, after the early 1970s when most were circuit-breaker types.

    WikipediaReference
    Quote
    “GFCIs built into the outlet receptacle became commonplace beginning in the 1980s.” Wikipedia
  2. 1978–1997circa

    Plumbing

    Polybutylene water pipe used in houses

    WikipediaReference

Events come from a researched timeline of 150 dated changes to US homebuilding, each checked against the quoted source. Primary source is a government or standards body, Trade reference a trade body and Reference a general reference such as Wikipedia. A date is when something began or became required, not when every builder followed.

The year in context · building

Housing that year

How many new homes were started across the US in 1988, against every year since 1889. It is the whole country’s building, houses and apartments, not a count of houses like this one.

New homes started · 1988 · US

About 1.49 million new homes (houses and apartments) were started in 1988, the fewest since 1982, and 8% fewer than in 1987.

Started
1.49 million
Median new house price
$112,5001988 $
In one-family buildings
73%
  • Before 1959 the counts are historical estimates: Historical Statistics of the United States reconstructed them from building permits and other records, in series that change method in 1920, 1930 and 1945. They leave out farm housing. The figures here were transcribed by hand from a scanned copy and checked against the table’s own totals.
  • From 1959 the count is the Census Bureau’s privately owned housing units started; public housing is not in it. Mobile homes, conversions and temporary units are never counted.
  • The median new house price is in the dollars of 1988, not adjusted for inflation.

Source US Census Bureau, Historical Statistics of the United States, Colonial Times to 1970, Series N 156 (1889–1958); New Residential Construction, annual housing starts (1959–2025); New Residential Sales, median sales price of new houses sold.

As built · new houses of 1988

The typical new house of 1988

How new single-family houses completed in 1988 across the US were built, from the US Census Bureau’s Survey of Construction. These describe that year’s new houses, not this one, and a house may have been altered since.

Showing the whole US · choose your state above, or a region here

Region

New houses · 1988 · US

Most often: one story or two, with a slab or other foundation or a basement, wood outside, gas heat and air-conditioning.

Median size
1,810sq ft
Completed
1,085,000houses

Median size, sq ft

  1. Floors

    49% 2 stories or more (incl. 1½)

    • 1 story46%
    • 2 or more49%
    • Split-level4%
    • Floors are counted two ways: through 2008, 1 story, 2 or more, and split-level; from 2009, split-level and 1½-story houses count as 2 stories and 3 or more is separate. Only “1 story” is roughly comparable across the change.

    2 or more, over time

  2. Foundation

    41% Slab or other (piers, pilings)

    • Basement39%
    • Slab or other41%
    • Crawl space19%
    • The Census counts slabs together with other foundations such as piers and pilings, so this is “slab or other”, never slab alone.

    Slab or other, over time

  3. Outside walls

    42% Wood

    • Brick17%
    • Wood42%
    • Stucco16%
    • Other, incl. vinyl26%
    • Vinyl siding was not counted separately until 1992. Before then it sits inside “other”, with aluminum, block and stone.
    • Fiber cement was not counted separately until 2005. Before then it sits inside “other”.

    Wood, over time

  4. Heating fuel

    54% Gas (natural or bottled)

    • Gas54%
    • Electricity37%
    • Oil6%
    • Other or none3%
    • Gas includes bottled gas and propane as well as natural gas.

    Gas (natural or bottled), over time

  5. Heating system

    60% Forced-air furnace

    • Forced-air furnace60%
    • Heat pump26%
    • Hot water or steam7%
    • Other or none8%

    Forced-air furnace, over time

  6. Air-conditioning

    75% With air-conditioning

    • With air-conditioning75%
    • Without25%

    With air-conditioning, over time

  7. Bedrooms

    57% 3 bedrooms

    • 2 or fewer17%
    • 357%
    • 4 or more26%

    3 bedrooms, over time

  8. Bathrooms

    44% 2 bathrooms

    • 1½ or fewer15%
    • 244%
    • 2½28%
    • 3 or more14%

    2 bathrooms, over time

  9. Garage

    66% Garage for 2 or more cars

    • 1-car garage12%
    • 2+ car garage66%
    • Carport3%
    • None18%
    • Garages for 3 or more cars were counted with 2-car garages until 1992.

    Garage for 2 or more cars, over time

  10. Fireplaces

    59% 1 fireplace

    • None35%
    • 159%
    • 2 or more6%

    1 fireplace, over time

  • These are new single-family houses completed that year in that region, including houses built for rent. They describe how houses were being built, not any one house.
  • Counts before 1999 include a 3.3 percent upward adjustment for houses built without permits in areas that issue permits, so house counts before and after 1999 are not strictly comparable.
  • These are survey estimates. Sampling error is larger for older years, for single regions and for small categories; “withheld” marks cells the Census did not publish.
  • Roofing is not recorded by this survey. Houses were not counted by state, so a region is the closest view.

Source US Census Bureau, Survey of Construction (Characteristics of New Housing), houses completed. Tables: Stories (2008 report), Foundation, Exterior Wall Material, Heating Fuel, Heating System, Air-Conditioning, Bedrooms, Bathrooms, Parking Facility, Fireplaces, Square feet.

As they stand today · houses built in the 1980s

Houses of the 1980s, today

The typical new house above is how houses were built in 1988. This is the other view: houses built in the 1980s that are still standing and lived in, as they are now, after decades of new roofs, new siding and renovation. Not as they were built.

Showing the whole US · detached single-family houses

Region

Roofs today · built in the 1980s · US

About 4 in 5 surviving houses from the 1980s across the US have asphalt shingle roofs today, and about 1 in 12 has a metal roof.

Roof material as reported in 2020. Most roofs have been replaced at least once since these houses were built, so this is what is on them now.

Homes sampled
1,434
Average size
2,283sq ft
  • Asphalt shingles79%
  • Metal8%
  • Wood shakes5%
  • Slate1%
  • Clay tile5%
  • Concrete tile3%
  • Other1%

1,434 homes sampled · EIA RECS 2020

Asphalt shingles, by era built

The shell

  1. Outside walls

    34% Siding: vinyl, aluminum, fiber cement or steel

    • Siding34%
    • Brick24%
    • Wood24%
    • Stucco13%
    • Stone1%
    • Concrete block4%
    • Other1%

    1,434 homes sampled · EIA RECS 2020

    Siding, by era built

  2. Window glass

    73% Double-pane

    • Single-pane25%
    • Double-pane73%
    • Triple-pane2%

    1,434 homes sampled · EIA RECS 2020

    Double-pane, by era built

  3. Foundation

    45% Slab

    • Full basement24%
    • Part basement9%
    • Crawl space21%
    • Slab45%
    • Other1%

    3,670 homes sampled · AHS 2023

    Slab, by era built

  4. Stories

    55% 1 story

    • 1 story55%
    • 2 stories38%
    • 3 or more3%
    • Split-level4%

    1,434 homes sampled · EIA RECS 2020

    1 story, by era built

Heating and cooling

  1. Main heating fuel

    46% Electricity

    • Gas40%
    • Electricity46%
    • Oil4%
    • Propane6%
    • Wood3%
    • Other1%

    3,670 homes sampled · AHS 2023

    Electricity, by era built

  2. Main heating equipment

    68% Forced warm-air furnace

    • Furnace68%
    • Boiler6%
    • Heat pump16%
    • Electric baseboard3%
    • Wall or room heater3%
    • Stove or fireplace2%
    • Other or none2%

    3,670 homes sampled · AHS 2023

    Forced warm-air furnace, by era built

  3. Air-conditioning

    82% Central air

    • Central air82%
    • Room units only11%
    • None7%

    3,670 homes sampled · AHS 2023

    Central air, by era built

The rooms

  1. Bathrooms

    41% Two full bathrooms

    • No full bath<0.5%
    • 111%
    • 1½8%
    • 241%
    • 2½21%
    • 3+19%

    3,670 homes sampled · AHS 2023

    Two full bathrooms, by era built

  2. Fireplace

    55% Usable fireplace

    • Usable fireplace55%
    • None46%

    3,670 homes sampled · AHS 2023

    Usable fireplace, by era built

  3. Size

    28% 1,500 to 1,999 sq ft

    • Under 1,0007%
    • 1,000–1,49922%
    • 1,500–1,99928%
    • 2,000–2,49919%
    • 2,500+24%

    3,495 homes sampled · AHS 2023

    1,500 to 1,999 sq ft, by era built

  4. Garage or carport

    86% Garage or carport

    • Garage or carport86%
    • Neither14%

    3,653 homes sampled · AHS 2023

    Garage or carport, by era built

  • Surviving detached single-family houses as they are today, by the decade their occupants say they were built. Roofs, siding, windows and heating include every replacement since. Houses that were torn down are not in it, so this is not how the era built.
  • In the Census Bureau’s words, “some of the home characteristics … may have been more recent additions or installations and did not come with the home when it was originally built.”
  • Survey estimates from samples of homes: a band with fewer than 30 sampled homes is never shown, and one with fewer than 100 is marked small sample. The EIA survey covers occupied primary homes only; the American Housing Survey also counts vacant ones.

Source US Energy Information Administration, Residential Energy Consumption Survey 2020, public microdata (roof, walls, window glass, stories, size); US Census Bureau and HUD, American Housing Survey 2023, national public use file (everything else); shares computed from the public microdata with the surveys’ weights. Caveat quoted from Census working paper 2011-18.

The year in context · the country

The country in 1990

From the 1990 census, the one nearest 1988. These describe every home standing at the time, old and new, not houses built that year.

Housing facts from the 1990 census, the US
FactUS
Lacking complete plumbinghot and cold piped water, a bathtub or shower, and a flush toiletCensus, plumbing1.1%
Main house heating fuelsoccupied homesCensus, house heating fuelutility gas 51.0%electricity 25.8%oil or kerosene 12.2%bottled gas 5.7%
On a public sewerseptic tank or cesspool: 24.1% across the USCensus, sewage disposal74.8%
Water from a public system or companyown well: 14.8% across the USCensus, source of water84.2%
Homes owned by the people living in themCensus, homeownership64.2%
Homes built in the 1980s still standing todayACS 2020-2024, B2503418.5 million 12.9% of homes
Half of all homes standing today were built beforethe median year builtACS 2020-2024, B250351980

Census figures are shares of homes counted in 1990. Today’s count is the US Census Bureau’s American Community Survey, 2020 to 2024, which includes vacant homes and dates them by what residents report. Choose your state above to see it beside the US.

See something in the 1988 report that looks wrong?Report an error on this page