About 250,000 gas furnaces and boilers were vented through gray or black plastic pipe printed Plexvent or Ultravent, which was recalled because joints can crack or separate and leak carbon monoxide.

Houses built
1988–1994
Dates from
Court record: Dates come from a court settlement or a product recall.
How common
Rare
Priority
Worth a look
Mainly about
Safety
Where to look
Heating & cooling · Basement & foundation · Exterior walls

What it is

In 1998 CPSC announced a program to replace this high-temperature plastic vent (HTPV) pipe free of charge on about 250,000 systems; about 93,000 had been replaced by October 2005. The danger is carbon monoxide escaping from cracked or separated joints. CPSC gives dates only for a subset on Goodman furnaces, made October 1988 to July 1994.

How sure the dates are

Court record: Dates come from a court settlement or a product recall.

Dates come from a court settlement or a product recall. What the labels mean

How common it is

Rare

CPSC: about 250,000 systems nationally, about 93,000 of them replaced by October 2005.

The years

Houses built from 1988 to 1994 may have it.

Earliest
About 1988An approximate date. It came in gradually, and sources differ by a few years.
Most likely
Not narrowedSources give no narrower window, so treat every year in the range alike.
Latest
About 1994An approximate date. The change came gradually, so a few later houses may have it.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

How to check

  1. Follow the flue pipe from the furnace or boiler to where it leaves the house, usually through a side wall.

  2. Gray or black plastic pipe printed 'Plexvent', 'Plexvent II' or 'Ultravent' is the recalled type.

  3. White PVC or CPVC pipe is not part of the recall.

Where to look
  • Heating & cooling
  • Basement & foundation
  • Exterior walls

What to do

If you find itHave a heating contractor inspect it promptly. At this age, replacing the vent along with the appliance is often the realistic fix. Whether any recall remedy is still honored is unknown.

Sources

4 verified sources, 4 primary. Each quote is copied word for word from the page linked.

  1. CPSC (2009 re-announcement)Primary source

    about 10,000 Plexvent and Ultravent HTPV pipe systems attached to certain Goodman mid-efficiency furnaces manufactured from October 1988 to July 1994

    cpsc.gov/Recalls/2009/CPSC-Goodman-Manufacturing-Co-A… (opens in a new tab)
  2. CPSC (Feb 1998 programme)Primary source

    This program will replace, free of charge, an estimated 250,000 HTPV pipe systems attached to gas or propane furnaces or boilers in consumers' homes.

    cpsc.gov/Recalls/1998/cpsc-manufacturers-announce-rec… (opens in a new tab)
  3. CPSCPrimary source

    The program's purpose is to replace, free of charge, an estimated 250,000 HTPV pipe systems attached to gas or propane furnaces or boilers in consumers' homes.

    cpsc.gov/Newsroom/News-Releases/1999/CPSC-Urges-Seaso… (opens in a new tab)
  4. CPSC (release dated 7 Nov 2005)Primary source

    About 93,000 HTPV pipes have been replaced as of October 1, 2005.

    cpsc.gov/Newsroom/News-Releases/2006/CPSC-Announces-V… (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Applies to houses built

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.