Often present · Heating & cooling
Rinnai EnergySaver wall furnaces (2008 recall)
Some Rinnai direct-vent wall heaters made from 2000 to 2007 have a gasket that can fail and leak carbon monoxide.
- Houses built
- 2000–2007
- Dates from
- Court record: Dates come from a court settlement or a product recall.
- How common
- No reliable count exists
- Priority
- Worth a look
- Mainly about
- Safety
- Where to look
- Heating & cooling
What it is
Rinnai recalled about 52,000 EnergySaver direct-vent wall furnaces, models RHFE-431 and RHFE-556, made from February 2000 to December 2007. A gasket can fail and let carbon monoxide into the home; Rinnai had 11 reports of leaks and no injuries. The notice told owners to stop using the furnace and offered a free repair kit.
How sure the dates are
Court record: Dates come from a court settlement or a product recall.Dates come from a court settlement or a product recall. What the labels mean
How common it is
No reliable count existsAbout 52,000 units were recalled; no count of affected homes exists.
The years
Houses built from 2000 to 2007 may have it.
- Earliest
- 2000A fixed date, set by a rule, a recall or a court record.
- Most likely
- Not narrowedSources give no narrower window, so treat every year in the range alike.
- Latest
- 2007A fixed date, such as a ban, a recall or a code change.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
Year predicts poorly
This was often added to older houses later, so check for it whatever the build year.
How to check
Look for a Rinnai heater mounted on an outside wall with its vent going straight through the wall.
Find the rating plate on the right side of the unit; the model number is at the top.
Look for RHFE-431 or RHFE-556 (with FAIII, WTA or WTA-72B/76B suffixes).
The first four digits of the serial number, at the bottom of the plate, are the year and month made: 0002 through 0712 are in the recall window.
- Heating & cooling
What to do
If you find itIf it matches, contact Rinnai about the free repair kit using the details on the recall notice, and check the notice for whether it is still offered. Make sure there is a working CO alarm nearby.
Sources
5 verified sources, 5 primary. Each quote is copied word for word from the page linked.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2008/rinnai-recalls-wall-furnaces-du… (opens in a new tab)The recall includes only those units manufactured from February 2000 through December 2007.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2008/rinnai-recalls-wall-furnaces-du… (opens in a new tab)About 52,000
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2008/rinnai-recalls-wall-furnaces-du… (opens in a new tab)Rinnai has received 11 reports of carbon monoxide leaking from the furnace. No injuries have been reported.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2008/rinnai-recalls-wall-furnaces-du… (opens in a new tab)Consumers should stop using the furnace immediately and contact the firm to arrange for the installation of a free repair kit.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2008/rinnai-recalls-wall-furnaces-du… (opens in a new tab)Units: About 52,000
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.