Often present · Heating & cooling
Lochinvar, A. O. Smith and State condensing boilers (2020 recall)
Some high-efficiency home boilers sold from 2016 to 2020 have a flue seal that can wear out and let carbon monoxide escape.
- Houses built
- 2016–2020
- Dates from
- Court record: Dates come from a court settlement or a product recall.
- How common
- No reliable count exists
- Priority
- Worth a look
- Mainly about
- Safety
- Where to look
- Heating & cooling
What it is
About 34,300 condensing boilers, combi boilers and packaged systems sold from August 2016 to June 2020 under the Lochinvar, A. O. Smith and State Proline names were recalled. A flue grommet can deteriorate and let carbon monoxide escape. The firm had 7 reports of failing grommets, including one report of two nonfatal carbon monoxide injuries, and the listed remedy is a repair.
How sure the dates are
Court record: Dates come from a court settlement or a product recall.Dates come from a court settlement or a product recall. What the labels mean
How common it is
No reliable count existsAbout 34,300 units were recalled in the US; no count of affected homes exists.
The years
Houses built from 2016 to 2020 may have it.
- Earliest
- 2016A fixed date, set by a rule, a recall or a court record.
- Most likely
- Not narrowedSources give no narrower window, so treat every year in the range alike.
- Latest
- 2020A fixed date, such as a ban, a recall or a code change.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
Year predicts poorly
This was often added to older houses later, so check for it whatever the build year.
How to check
Check whether the boiler is branded Lochinvar, A. O. Smith or State Proline.
Find the rating plate on the outer jacket or the underside of the front panel, with the model and serial number.
The notice lists serial numbers 103475818 through 115078306 and model families such as ACB, KHB, SCB and WHL. Compare yours with the full list.
- Heating & cooling
What to do
If you find itLook up the serial number at waterheaterrecall.com, as the notice directs. If it matches, contact Lochinvar or your installer about the repair and check whether it is still offered. Keep a working CO alarm near the boiler and bedrooms.
Sources
5 verified sources, 5 primary. Each quote is copied word for word from the page linked.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2020/Lochinvar-Recalls-Condensing-Re… (opens in a new tab)About 34,300 (In addition, about 3,642 units were sold in Canada)
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2020/Lochinvar-Recalls-Condensing-Re… (opens in a new tab)from August 2016 through June 2020, for between $8,000 and $25,000, including installation
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2020/Lochinvar-Recalls-Condensing-Re… (opens in a new tab)The firm has received 7 reports of boiler’s flue grommets deteriorating, including one report of two nonfatal injuries involving carbon monoxide poisoning, and two reports of carbon monoxide emission not involving an injury.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2020/Lochinvar-Recalls-Condensing-Re… (opens in a new tab)Remedy: Repair
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2020/Lochinvar-Recalls-Condensing-Re… (opens in a new tab)Check for the recalled boilers’ serial number at: www.waterheaterrecall.com
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.