Synthetic stucco (barrier EIFS)

Synthetic stucco over wood framing sounds hollow when you knock on it, and the early 'barrier' kind could trap water and rot the wall behind.

Houses built
1980–1999
Dates from
Approximate era: Dates are an approximate era drawn from trade and reference sources.
How common
Rare
Priority
Worth a look
Mainly about
Cost
Where to look
Exterior walls · Windows

What it is

EIFS is foam board with a thin stucco-like finish. Leak problems showed up from the late 1980s, and building standards moved houses to drainable EIFS with a drainage cavity. In 1997 EIFS was about 4% of the residential siding market.

How sure the dates are

Approximate era: Dates are an approximate era drawn from trade and reference sources.

Dates are an approximate era drawn from trade and reference sources. What the labels mean

How common it is

Rare

EIFS was about 4% of the US residential siding market in 1997 (Wikipedia, citing a trade source).

The years

Houses built from 1980 to 1999 may have it. It is most likely in houses built 1988 to 1996.

Earliest
About 1980An approximate date. It came in gradually, and sources differ by a few years.
Most likely
1988–1996The years it is most common: the solid part of the band.
Latest
About 1999An approximate date. The change came gradually, so a few later houses may have it.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

How to check

  1. Knock on or press the wall: synthetic stucco sounds hollow and gives slightly, while traditional stucco is hard.

  2. Look for foam showing at a damaged spot or at the bottom edge, and for finish running right down to or below the ground.

  3. Look for staining below window corners and where decks or roofs meet the wall.

Where to look
  • Exterior walls
  • Windows

What to do

If you find itBefore buying, or if you see stains, get a moisture-probe inspection by a certified EIFS inspector. Dry walls may need only flashing and sealant work; wet walls may need stripping and re-cladding with a drained system.

Sources

4 verified sources. Each quote is copied word for word from the page linked.

  1. InterNACHI, Water Damage and EIFSTrade reference

    It has been in use in Europe since the 1950s, and in the U.S. since the late ‘60s. It is often used on wood-framed houses.

    nachi.org/water-damage-eifs.htm (opens in a new tab)
  2. InterNACHI, How to Inspect for Moisture Intrusion (2012)Trade reference

    building standards only allow the use of a new type of drainable EIFS (i.e., drained cavity) on residential construction

    nachi.org/documents2012/How_to_Inspect_for_Moisture_I… (opens in a new tab)
  3. Wikipedia, Exterior insulation finishing systemReference

    As of 1997 EIFS accounted for about 4% of the residential siding market and 12% of the commercial siding market.

    en.wikipedia.org/wiki/Exterior_insulation_finishing_s… (opens in a new tab)
  4. Wikipedia, Exterior insulation finishing system (second excerpt)Reference

    In the late 1980s problems started developing due to water leakage in EIFS-clad buildings.

    en.wikipedia.org/wiki/Exterior_insulation_finishing_s… (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Applies to houses built

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.