Report · houses built in
What a house built in 1998 often has
- Age
- 28yrs
- On record
- 20
- Check first
- 1
- Built without
- 5
Choose one to hide issues that only apply elsewhere.
Headline findingCheck first
Cadet and Encore wall heaters
1978–2000Court record: Dates come from a court settlement or a product recall.
More than 1.9 million Cadet and Encore in-wall electric heaters, sold mainly in the Northwest and California from about 1978 to 2000, were recalled as a fire hazard.
20 things on record apply to a 1998 house: 1 to check first, 5 protections it was built without, and 14 more by part of the house.
Where 1998 sits among every issue on record
Point at a band to read it · drag or use the arrow keys to compare yearsWhat the 1998 line crosses20 bands
- Electrical
- Plumbing
- Hazardous materials
- Roof, walls & windows
- Structure
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
Check these first
The item most worth a look in a 1998 house: safety first, then cost.
Cadet and Encore wall heaters
More than 1.9 million Cadet and Encore in-wall electric heaters, sold mainly in the Northwest and California from about 1978 to 2000, were recalled as a fire hazard.
How to checkWalls, ceilings & floors · Heating & cooling
- Look through the grille of each electric wall heater for the label on the front of the heater assembly; do not take anything apart.
- Recalled models start with FW, FX, LX, TK, ZA, Z, RA, RK, RLX, RX, RW or ZC followed by three digits.
- The brand will be Cadet or Encore.
If you find itStop using any recalled heater and replace it with a current model. The recall remedy was not found to be still running, so contact Cadet to ask before paying for replacements.
How commonCPSC: more than 1.9 million units, concentrated in five states. No figure gives the share of houses; it applies mainly to houses with electric wall heat.
Keep in mindCPSC gives the sale years only as 'about' 1978 through 2000, and only the listed model prefixes are affected. Heaters were also fitted as replacements in older houses.
Details and 7 sources →1978–2000
Court record: Dates come from a court settlement or a product recall.Possible
Built without
Protections that became standard after 1998. A house keeps what it was built with unless someone added them, and many have been.
Florida home built before the statewide wind code
Florida homes built before the statewide Florida Building Code took effect on March 1, 2002 were built to earlier local codes; the statewide code followed Hurricane Andrew.Florida homes built before the statewide Florida Building Code took effect on March 1, 2002 were built to earlier local codes; the statewide code followed Hurricane Andrew.
Read the full entry →Built 2002 or earlier
Approximate era: Dates are an approximate era drawn from trade and reference sources.LikelyHow to check
- In the attic at the eaves, look where each truss or rafter meets the top of the wall.
- Only angled nails means toe-nailed; a small metal bracket is a clip; a metal strap wrapping over the truss is a wrap, and two straps a double wrap.
- Check windows and doors for impact-rated labels or shutter hardware.
- Your county permit record gives the original permit date.
If you find itGet a wind-mitigation inspection by a licensed inspector; it records these features for your insurer. Upgrades such as roof-to-wall straps, re-nailing the roof deck and shutters are usually done at re-roofing time.
How commonWikipedia puts the number of Florida homes that predate the modern code at about 4.7 million; every Florida home built before March 2002 predates it.
Keep in mindHouses finished around 2002 can go either way, depending on when they were approved. In South Florida's High-Velocity Hurricane Zones the stricter code dates from 1994. Some pre-2002 homes do have clips or straps.
Details and 4 sources →Gas water heaters made before 2003 (no flammable-vapor protection)
Standard gas tank water heaters made after July 1, 2003 are built to resist igniting gasoline fumes; older ones are not.Standard gas tank water heaters made after July 1, 2003 are built to resist igniting gasoline fumes; older ones are not.
Read the full entry →Built 2003 or earlier
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Check whether the water heater is a gas tank model (a burner at the bottom and a vent pipe on top).
- Read the label for the words 'Flammable Vapor Ignition Resistant' or 'FVIR'.
- Look for the manufacture date in the label or serial number: after July 2003 means it should have the protection.
- Notice whether gasoline, paint thinner or solvents are stored near it, especially in a garage.
If you find itKeep gasoline and solvents well away from any gas appliance. If the heater predates the standard, plan to replace it with a current model.
How commonAny gas tank heater made before July 2003 lacks it. Many heaters that old have been replaced; no count of how many remain exists.
Keep in mindThis was a voluntary industry standard, not a federal law, and it covers standard 30, 40 and 50 gallon gas tank heaters. Water heaters are replaced often, so the heater's own date matters far more than the house's.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 4 sources →No arc-fault (AFCI) breakers
Arc-fault breakers, which detect the sparking that can start wiring fires, were first required in bedrooms of new houses in 2002.Arc-fault breakers, which detect the sparking that can start wiring fires, were first required in bedrooms of new houses in 2002.
Read the full entry →Built 2004 or earlier1998 is in the peak years
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Open the panel door and look for breakers with a TEST button labeled AFCI, 'Arc Fault', 'Combination AFCI' or 'Dual Function'.
- Ordinary breakers have no test button.
If you find itThis is an optional upgrade: an electrician can fit AFCI or dual-function breakers where your panel supports them.
How commonNo reliable count exists. Houses built before about 2002 will lack AFCIs unless they were added later.
Keep in mindStates adopt each code edition on their own schedule, so build year is a weak guide on its own. Only the 2002 bedroom date is confirmed by a primary source.
Details and 2 sources →Outlets without child-safety shutters
Since the 2008 electrical code, new houses get outlets with built-in shutters that stop a child pushing a key or hairpin into the slot.Since the 2008 electrical code, new houses get outlets with built-in shutters that stop a child pushing a key or hairpin into the slot.
Read the full entry →Built 2010 or earlier1998 is in the peak years
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Look closely at an outlet: 'TR' embossed on the face between the slots means tamper-resistant.
- You can see plastic shutters inside the slots.
If you find itIf small children live in or visit the house, have outlets replaced with TR-listed ones.
How commonNo reliable count exists. Houses built before their state adopted the 2008 code will generally lack them unless outlets were replaced.
Keep in mind2008 is the model code year; states adopted it at different times. As of 2016, the rule did not apply to manufactured homes.
Details and 3 sources →Built before mandatory airtightness testing (2012 energy code)
The 2012 energy code was the first to make new houses pass a whole-house air leakage test.The 2012 energy code was the first to make new houses pass a whole-house air leakage test.
Read the full entry →Built 2015 or earlier
Federal rule: Dates come from a federal rule or a model building code.LikelyHow to check
- Look near the electrical panel or furnace for an energy code certificate or a posted blower-door test result.
- Ask the seller or builder whether a blower-door test or energy rating was done.
- Notice drafts around outlets, attic hatches, recessed lights and window trim on a cold or windy day.
If you find itNothing is required. If the house feels drafty or bills are high, an energy audit with a blower-door test shows where air sealing would help most.
How commonHouses built before their state adopted the 2012 code were not required to pass this test. Adoption dates by state were not researched.
Keep in mindThis is a model code. States and cities adopted it at different times, so the end year here is stretched a few years and is soft. Check your state's adoption date.
Details and 3 sources →
Everything else, by part of the house
Materials and products often installed in 1998. Open any row for how to check.
Where to look. Each number counts the items in this report for that part of the house.
Plumbing & water1
Kitec plumbing
Kitec plumbing, often bright orange and blue pipe with brass fittings, was recalled by its maker in 2005 because the fittings corrode quickly.Kitec plumbing, often bright orange and blue pipe with brass fittings, was recalled by its maker in 2005 because the fittings corrode quickly.
Read the full entry →1992–20071998 is in the peak years
Approximate era: Dates are an approximate era drawn from trade and reference sources.RareHow to check
- Look at the water heater, under sinks and at any manifold: Kitec pipe is usually bright orange (hot) and bright blue (cold).
- Read the print on the pipe for the Kitec name.
- Brass fittings are stamped 'Kitec' or 'KTC'.
- Some houses have a warning sticker inside the electrical panel door.
If you find itIf you find it, talk to a plumber about replacing it; a full repipe is the usual fix. No open compensation program was found.
How commonInterNACHI counts at least 60,000 homes in southern Nevada and New Mexico from lawsuits filed, and says tens of thousands more are likely in parts of Arizona, California and Texas. Nationally it is rare.
Keep in mindThe 1995 to 2007 window is the commonly quoted one; InterNACHI says it was in use from the early 1990s, and the end year is unconfirmed. It is concentrated in a few western markets, and most houses of the era never had it.
Details and 2 sources →
Kitchen & bath1
Kidde plastic-handle fire extinguishers (2017 recall)
Kidde recalled about 37.8 million fire extinguishers because some may not spray when you need them.Kidde recalled about 37.8 million fire extinguishers because some may not spray when you need them.
Read the full entry →1973–2017
Court record: Dates come from a court settlement or a product recall.No reliable count existsHow to check
- Look under the kitchen sink, in the pantry, garage and utility room for any Kidde extinguisher.
- Note whether it has a plastic handle (red, white or silver models) or a push-button Pindicator top.
- Read the model number on the label and compare it with the model list on the CPSC recall notice.
- On units made in 2007 or later, a 10-digit date code is printed on the side of the cylinder near the bottom.
If you find itIf the model is on the list, replace it and contact Kidde through the product safety recall page on kidde.com. Check the recall notice for whether the replacement offer is still open.
How commonAbout 37.8 million units were recalled in the US; no count of affected homes exists.
Keep in mindExtinguishers are bought, not built in, so the year a house was built predicts little: owners add them to houses of every age. The recall did not cover every Kidde extinguisher, only the listed models.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 4 sources →
Heating, cooling & chimney1
R-22 (Freon) air conditioner
Since January 1, 2010, EPA has barred making new air conditioners or pre-charged parts with R-22, and US production and import of the refrigerant ended in 2020.Since January 1, 2010, EPA has barred making new air conditioners or pre-charged parts with R-22, and US production and import of the refrigerant ended in 2020.
Read the full entry →Built 2009 or earlier
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Read the data plate on the outdoor unit: 'R-22' or 'HCFC-22' means the old refrigerant; newer units say R-410A, R-454B or R-32.
- The manufacture date is usually on the same plate.
If you find itNothing to do while it works. Budget for replacing the outdoor unit and indoor coil together when it fails.
How commonNo reliable count exists of pre-2010 units still in service.
Keep in mindAir conditioning is often added or replaced long after a house is built, so the unit's age matters far more than the house's.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 5 sources →
Roof & attic3
Atlas Chalet and Stratford shingles
Atlas Chalet and Stratford shingles, sold from at least 1998 until 2010, drew federal lawsuits, and in 2017 a federal court in Georgia denied class certification.Atlas Chalet and Stratford shingles, sold from at least 1998 until 2010, drew federal lawsuits, and in 2017 a federal court in Georgia denied class certification.
Read the full entry →1998–2010
Court record: Dates come from a court settlement or a product recall.No reliable count existsHow to check
- Look at the roof from the ground: they resemble three-tab shingles with a darker printed shadow band across each tab.
- Look for small pock-like blisters and bald spots.
- Roofers in the Southeast tend to recognize them on sight.
If you find itHave a roofer look if you see blistering. No class settlement was found, so replacement is usually at the owner's cost unless an insurer accepts a storm claim, and because they are discontinued, matching repairs is difficult.
How commonNo reliable count exists, and no data on where they were most used was found.
Keep in mindThe first year of sale is uncertain; the court says only 'in the 1990s'. Many roofs from this period have been replaced, and most houses of the era have other shingles.
Details and 4 sources →CertainTeed organic shingles
CertainTeed estimated that about 1.86 million buildings got its felt-based organic shingles between 1987 and 2005, and a class settlement followed.CertainTeed estimated that about 1.86 million buildings got its felt-based organic shingles between 1987 and 2005, and a class settlement followed.
Read the full entry →1987–2006
Court record: Dates come from a court settlement or a product recall.RareHow to check
- Look for CertainTeed wrappers, invoices or warranty papers and check whether they describe an organic (felt) shingle rather than fiberglass.
- A torn shingle shows a brown or black felt core rather than white glass fibers.
- Heavy curling at tab corners and blistering on an old roof are typical of organic shingles.
If you find itIf the roof is failing, re-roof. Contact CertainTeed to ask whether claims are still possible; the claim deadline could not be confirmed.
How commonCertainTeed's own estimate in court: about 1,857,000 structures were built with these shingles from 1987 to 2005, a small share of roofs laid in those years.
Keep in mindMany roofs from this period have already been replaced, and the older the house, the less likely the original roof survives. Installation could trail manufacture by a year or so.
Details and 3 sources →Factory-built roof trusses
If your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.If your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.
Read the full entry →Built 1955 or later
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- In the attic, look for diagonal 2x4s forming W or M shapes, joined by toothed galvanized steel plates.
- Rafters, by contrast, are larger boards running from the ridge to the wall with open space between.
- Look for cut or notched members and plates that have backed out of the wood.
If you find itNothing is needed unless trusses are damaged or altered. Before any attic conversion, skylight or other change that touches a truss, get an engineer's design.
How commonNo reliable count exists for houses by year built.
Keep in mindTruss use grew over decades, and many houses still use rafters, especially custom homes and complex roofs. A reference source dates the connector plate to 1955.
Details and 1 source →
Exterior walls & windows3
Hardboard siding (Masonite and others)
Hardboard siding swells and rots when water gets in, and in 1996 a jury found Masonite's siding defective.Hardboard siding swells and rots when water gets in, and in 1996 a jury found Masonite's siding defective.
Read the full entry →1980–1998
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Look at cut ends or where paint has failed: smooth or embossed board of uniform brown fiber, with no visible strands or plies.
- Check bottom edges, butt joints and around nails for swelling, 'mushroomed' nail heads and soft spots.
If you find itKeep paint and caulk in good shape, replace damaged boards, or re-side when damage spreads. No open claim program was found.
How commonNo reliable count exists, and no confirmed figure for the size of the Masonite class was found.
Keep in mindThe 1980 to 1998 range is the reported Masonite class window, which could not be confirmed, and hardboard was used before 1980 too. Brands look alike, so the maker is hard to tell from the outside.
Details and 2 sources →Synthetic stucco (barrier EIFS)
Synthetic stucco over wood framing sounds hollow when you knock on it, and the early 'barrier' kind could trap water and rot the wall behind.Synthetic stucco over wood framing sounds hollow when you knock on it, and the early 'barrier' kind could trap water and rot the wall behind.
Read the full entry →1980–1999most likely 1988–1996
Approximate era: Dates are an approximate era drawn from trade and reference sources.RareHow to check
- Knock on or press the wall: synthetic stucco sounds hollow and gives slightly, while traditional stucco is hard.
- Look for foam showing at a damaged spot or at the bottom edge, and for finish running right down to or below the ground.
- Look for staining below window corners and where decks or roofs meet the wall.
If you find itBefore buying, or if you see stains, get a moisture-probe inspection by a certified EIFS inspector. Dry walls may need only flashing and sealant work; wet walls may need stripping and re-cladding with a drained system.
How commonEIFS was about 4% of the US residential siding market in 1997 (Wikipedia, citing a trade source).
Keep in mindStart and end years are approximate, and the move to drainable EIFS did not happen everywhere at the same time.
Details and 4 sources →Pella ProLine casement windows
Pella ProLine aluminum-clad wood casement, awning and transom windows made from 1991 to 2009 were the subject of a class settlement over claims that water could get in and rot the wood.Pella ProLine aluminum-clad wood casement, awning and transom windows made from 1991 to 2009 were the subject of a class settlement over claims that water could get in and rot the wood.
Read the full entry →1991–2009
Court record: Dates come from a court settlement or a product recall.No reliable count existsHow to check
- Look for the Pella name etched in a corner of the glass or on the hardware.
- These windows have aluminum cladding outside and wood inside.
- Check the bottom of each sash for soft or stained wood.
If you find itReplace rotted sashes or whole units. The settlement's claim deadline could not be confirmed, so contact Pella or the settlement administrator to ask whether claims are still open.
How commonNo reliable count exists. This is one product line from one maker.
Keep in mindOnly casement, awning and transom windows in this line were covered. Windows are often replaced, so these can also turn up in older houses.
Details and 2 sources →
Foundation & basement3
Yellow CSST gas tubing without bonding
Flexible yellow stainless-steel gas tubing can be damaged by a nearby lightning strike, and older installs may lack the bonding wire that reduces the risk.Flexible yellow stainless-steel gas tubing can be damaged by a nearby lightning strike, and older installs may lack the bonding wire that reduces the risk.
Read the full entry →1990–2011
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- Look at exposed gas piping in the basement, attic, crawl space or at the furnace and water heater: flexible corrugated tubing in a yellow jacket is CSST (black-jacketed tubing is a newer type).
- Look for bonding: a clamp on a rigid gas fitting with a bare or green copper wire running to the electrical panel or grounding system.
If you find itIf you have yellow CSST and see no bonding wire, have a licensed electrician bond it following the tubing maker's instructions and current code. It is a small job.
How commonNo reliable count exists. It applies only to houses with gas service.
Keep in mindThe start year and the code year that made bonding mandatory were not confirmed, and states adopted codes at different times. CSST is still installed today, with bonding.
Details and 2 sources →Crumbling concrete foundations (pyrrhotite)
In parts of north-central Connecticut and central Massachusetts, some foundations poured with local quarry stone are crumbling because of a mineral called pyrrhotite.In parts of north-central Connecticut and central Massachusetts, some foundations poured with local quarry stone are crumbling because of a mineral called pyrrhotite.
Read the full entry →1983–2015
Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count existsHow to check
- In the basement, look at the foundation walls for horizontal cracks and map-pattern (spider-web) cracking.
- Look for white powdery deposits, rust-brown staining and flaking.
- A clean-looking wall does not rule it out; a licensed engineer's visual inspection and a core sample tested for pyrrhotite confirm it.
If you find itIf you are in an affected area, have a licensed engineer inspect the foundation, especially before buying, and check with your state about any current testing or repair assistance.
How commonNo reliable count exists. The problem is tied to aggregate from certain local quarries, so it is limited to parts of central Connecticut and Massachusetts.
Keep in mindThe 1983 to 2015 window comes from state officials' figures that could not be independently confirmed, and only towns near the source quarries are affected. Most houses in Connecticut and Massachusetts are not at risk.
Details and 2 sources →Engineered I-joist floors
By 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.By 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.
Read the full entry →Built 1970 or latermost likely from 2000
Approximate era: Dates are an approximate era drawn from trade and reference sources.PossibleHow to check
- Look up at the basement or garage ceiling for I-shaped joists: a thin OSB or plywood web with small lumber flanges top and bottom.
- They are usually printed with the maker's brand name.
- If you can see them, they are unprotected from below.
If you find itConsider covering exposed I-joists with drywall, and make sure working smoke alarms cover every level, including the basement.
How commonWikipedia: about 50% of wood light-frame floors used I-joists as of 2005.
Keep in mindNewer model codes are reported to require covering them, but that was not confirmed and code adoption varies by state. The hazard applies only where the joists are exposed.
Details and 2 sources →
Garage, deck & yard1
Arsenic-treated (CCA) deck lumber
Pressure-treated wood in decks and play sets built before 2004 was commonly treated with an arsenic compound, and EPA says never to burn it.Pressure-treated wood in decks and play sets built before 2004 was commonly treated with an arsenic compound, and EPA says never to burn it.
Read the full entry →1975–20041998 is in the peak years
Federal rule: Dates come from a federal rule or a model building code.No reliable count existsHow to check
- Look at decks, play sets, fences and garden edging built of pressure-treated wood before 2004.
- End tags or ink stamps may read 'CCA' with a number such as 0.40; newer wood reads ACQ, CA or MCA.
- Arsenic swab test kits and lab tests exist.
If you find itWash hands after contact, never burn the wood or use it for garden beds, and wear a mask when cutting it. Sealants may reduce surface arsenic, but CPSC testing found few held up after two years. Replace with alternative-treated wood or composite when the deck is due.
How commonNo reliable count exists. EPA says CCA-treated wood was used in decks and playsets before 2004, but no market-share figure was found.
Keep in mindAt manufacturers' request, EPA cancelled CCA for most residential wood, including decks, after December 30, 2003, but old stock could still be sold, so some decks built in 2004 may have used it. The 1975 start is approximate. Decks are often built or replaced long after the house, so the deck's age matters more than the house's.
Year predicts poorlyThis is often added to older houses later, so check whatever the build year.
Details and 10 sources →
Whole house1
Central, Gem and Star O-ring sprinkler heads (2001 recall)
If a house from around 1990 to 2001 has fire sprinklers, some heads from that era were recalled because they may not open in a fire.If a house from around 1990 to 2001 has fire sprinklers, some heads from that era were recalled because they may not open in a fire.
Read the full entry →1989–20011998 is in the peak years
Court record: Dates come from a court settlement or a product recall.RareHow to check
- First check whether the house has sprinklers: small heads on ceilings or high on walls.
- Look at the frame or deflector of each head for 'CENTRAL', 'STAR', the letters 'CSC', a 'G' in a triangle, or a star-shaped symbol.
- Compare any model or date stamped on the head with the CPSC model list.
If you find itThe free replacement program closed on August 31, 2007, so any affected heads would need replacing at your own cost. Have a fire sprinkler contractor confirm and replace them.
How commonNIST said in 2011 that fewer than 5 percent of US homes had fire sprinklers. No reliable count exists of houses with these heads.
Keep in mindDry-type heads in this recall go back to the mid-1970s, but these are rare in houses. Most houses of this era have no sprinklers, so this only matters if yours does.
Details and 7 sources →
What’s due at this age
A 1998 house is 28 years old. Here is where its parts stand against their typical life, and which ones have certainly been replaced by now.
- In their window
- 4
- Past life, if original
- 12
- Due within 5 yrs
- 3
- Replaced by now
- 20
20 of the 53 parts we track wear out so much faster than a 1998 house has stood that they have been replaced at least once. Know when something was last replaced? Enter the year (or a decade, like 2010s) and we’ll show where that part stands. It stays on this device only.
In the replacement window now
4If these are still the originals, they are inside their typical service life range. Worth budgeting for.
- Deck framingDeck & yard · lasts 10–30 yrs
Check for hidden rot where the ledger meets the house and at the posts. A deck that bounces or sways should be checked before anyone uses it.
10–30 yrsIn its windowif original - Aluminum gutters and downspoutsRoof · lasts 20–40 yrs
Sagging, leaking seams and water spilling over the edge are the signs. Failed gutters send water to the foundation.
20–40 yrsIn its windowif original - Septic systemDrains & sewer · lasts 15–40 yrs
Regular pumping and inspection extend life; the drainfield usually fails first. Slow drains, odors and wet or unusually green ground over the drainfield are the warning signs.
15–40 yrsIn its windowif original - Vinyl or fiberglass windowsWindows · lasts 20–40 yrs
Fogging between panes means the seal has failed. Warped frames and drafts are other signs.
20–40 yrsIn its windowif original
Past typical life, if still original
12Older than the usual range, but not so old that an original is unlikely. Worth finding out whether they have been replaced.
- Flat roof (EPDM rubber)Roof · lasts 15–25 yrs15–25 yrs3 yrs pastif original
- Forced-air furnaceHeating & cooling · lasts 15–25 yrs15–25 yrs3 yrs pastif original
- Garage doorGarage · lasts 20–25 yrs20–25 yrs3 yrs pastif original
- Vinyl floorWalls, ceilings & floors · lasts ~25 yrs~25 yrs3 yrs pastif original
- Wood shake roofRoof · lasts ~25 yrs~25 yrs3 yrs pastif original
- Aluminum windowsWindows · lasts 15–20 yrs15–20 yrs8 yrs pastif original
- Asphalt drivewayDeck & yard · lasts 15–20 yrs15–20 yrs8 yrs pastif original
- Asphalt shingle roof (3-tab)Roof · lasts ~20 yrs~20 yrs8 yrs pastif original
- Faucets and spray hoseBathroom · lasts 15–20 yrs15–20 yrs8 yrs pastif original
- Flat roof (modified bitumen)Roof · lasts ~20 yrs~20 yrs8 yrs pastif original
- Tankless water heaterWater heater · lasts 10–20 yrs10–20 yrs8 yrs pastif original
- Water softenerWater pipes · lasts ~20 yrs~20 yrs8 yrs pastif original
Coming due in the next five years
3Not yet, but close enough to plan for.
- Asphalt shingle roof (architectural)Roof · lasts ~30 yrs
Thicker laminated shingles last longer, but heat, hail and severe storms can cut that short. Ask for the roof's install date.
~30 yrsIn 2 yrsif original - GFCI outletsKitchen · lasts ~30 yrs
The chart says up to 30 years, but InterNACHI says much less if they trip regularly. Press the test button monthly; one that will not trip or reset must be replaced.
~30 yrsIn 2 yrsif original - Wood windowsWindows · lasts ~30 yrs
The chart says 30+ years. Paint and sealant upkeep decides it: peeling paint and soft sills mean rot is starting.
~30 yrsIn 2 yrsif original
Replaced at least once by now: find out when20
A 1998 house has outlasted these parts’ typical life at least once over, so what matters is when each was last replaced. Ask the seller or check receipts and date labels; enter a year and the part moves up to where it stands.
- Carbon monoxide alarmWhole houselasts ~5 yrs≈5 lifetimes
- Dryer vent (plastic)Whole houselasts ~5 yrs≈5 lifetimes
- Sump pumpBasement & foundationlasts ~7 yrs≈4 lifetimes
- DishwasherKitchenlasts ~9 yrs≈3 lifetimes
- CarpetWalls, ceilings & floorslasts 8–10 yrs≈3 lifetimes
- Caulking (interior and exterior)Exterior wallslasts 5–10 yrs≈3 lifetimes
- Exterior paintExterior wallslasts 7–10 yrs≈3 lifetimes
- Smoke alarmWhole houselasts ~10 yrs≈2 lifetimes
- Garbage disposalKitchenlasts ~12 yrs≈2 lifetimes
- Clothes dryerWhole houselasts ~13 yrs≈2 lifetimes
- RefrigeratorKitchenlasts 9–13 yrs≈2 lifetimes
- Central air conditionerHeating & coolinglasts 7–15 yrs≈2 lifetimes
- Electric rangeKitchenlasts 13–15 yrs≈2 lifetimes
- Garage door openerGaragelasts 10–15 yrs≈2 lifetimes
- Heat pumpHeating & coolinglasts 10–15 yrs≈2 lifetimes
- Tank water heaterWater heaterlasts 6–15 yrs≈2 lifetimes
- Washing machineBathroomlasts 5–15 yrs≈2 lifetimes
- Well pumpWater pipeslasts ~15 yrs≈1 lifetimes
- Wood deck boardsDeck & yardlasts ~15 yrs≈1 lifetimes
- Gas rangeKitchenlasts 15–17 yrs≈1 lifetimes
Further out14
- Boiler (hot-water or steam)Heating & coolinglasts ~40 yrsin 12 yrs
- Chimney flue tileChimneylasts 40–120 yrsin 12 yrs
- Concrete walkwayDeck & yardlasts 40–50 yrsin 12 yrs
- Metal roofRooflasts 40–80 yrsin 12 yrs
- Cast-iron drain pipe (below ground)Drains & sewerlasts 50–60 yrsin 22 yrs
- Copper water supply linesWater pipeslasts 50–70 yrsin 22 yrs
- Electrical service panelElectrical panellasts ~60 yrsin 32 yrs
- Heating and cooling ductworkHeating & coolinglasts 60–100 yrsin 32 yrs
- Vinyl sidingExterior wallslasts ~60 yrsin 32 yrs
- Clay or concrete tile roofRooflasts ~100 yrsin 72 yrs
- Fiber cement sidingExterior wallslasts ~100 yrsin 72 yrs
- Fiberglass exterior doorWhole houselasts ~100 yrsin 72 yrs
- Hardwood floorWalls, ceilings & floorslasts ~100 yrsin 72 yrs
- ToiletsBathroomlasts ~100 yrsin 72 yrs
Typical lives from InterNACHI Standard Estimated Life Expectancy Chart for Homes, CPSC, U.S. Department of Energy (hosted guide), US Department of Energy, Energy Saver Guide (2022), InterNACHI, Smoke Alarm Inspection, US EPA, New Homebuyer's Guide to Septic Systems, InterNACHI and U.S. Consumer Product Safety Commission. Real lives vary with climate, quality and upkeep.
Your place
Add a ZIP code for a few sourced facts about where the house stands: the homes around it, radon, climate and flood maps. All optional.
Looking up a ZIP code needs JavaScript. Everything else on this page works without it.
Part two
The year in context
What was changing around 1998, how much the country was building, how houses of this era stand today and what homes were like then. All of it describes houses in general, never this one.
The year in context · events
Around 1998: what was changing in homebuilding
The nearest dated events within 2 years either side. Each comes with its source and how strong that source is.
Nothing in our timeline is dated to 1998 itself.
Nearby, 1996 to 1999within 2 years of 1998
- 1978–1997circa
Plumbing
Polybutylene water pipe used in houses
In this report’s record of issues: Polybutylene water pipes
WikipediaReference - 1996
Policy
Lead disclosure rule for pre-1978 housing
HUD and EPA jointly issued the Lead Disclosure Rule in 1996, requiring sellers and landlords of most pre-1978 housing to disclose known lead paint information and provide a pamphlet.
U.S. Department of Housing and Urban DevelopmentPrimary sourceQuote
“by HUD and the Environmental Protection Agency (EPA) in 1996 (61 FR 9063-9088, March 6, 1996)” U.S. Department of Housing and Urban Development
- 1996
Plumbing
Lead leaching standards extended to fittings and fixtures
In 1996 Congress amended the Safe Drinking Water Act to require plumbing fittings and fixtures to meet voluntary lead leaching standards.
U.S. Environmental Protection AgencyPrimary sourceQuote
“In 1996 Congress further amended the Safe Drinking Water Act, requiring plumbing fittings and fixtures” U.S. Environmental Protection Agency
- 1997
Codes
Last edition of the Uniform Building Code
The 1997 edition was the final Uniform Building Code, replaced in 2000 by the International Building Code.
WikipediaReferenceQuote
“Updated editions of the code were published approximately every three years until 1997, which was the final version of the code.” Wikipedia
- 1999
Electrical
1999 NEC adds arc-fault protection and four-wire range and dryer receptacles
In this report’s record of issues: No arc-fault (AFCI) breakers
WikipediaReference - 1999
Policy
HUD Lead Safe Housing Rule
HUD issued the Lead Safe Housing Rule in 1999 for federally assisted pre-1978 housing.
U.S. Department of Housing and Urban DevelopmentPrimary sourceQuote
“The Lead Safe Housing Rule (LSHR) (24 CFR Part 35, subparts B-R) was issued by HUD in 1999” U.S. Department of Housing and Urban Development
Events come from a researched timeline of 150 dated changes to US homebuilding, each checked against the quoted source. Primary source is a government or standards body, Trade reference a trade body and Reference a general reference such as Wikipedia. A date is when something began or became required, not when every builder followed.
The year in context · building
Housing that year
How many new homes were started across the US in 1998, against every year since 1889. It is the whole country’s building, houses and apartments, not a count of houses like this one.
New homes started · 1998 · US
About 1.62 million new homes (houses and apartments) were started in 1998, the most since 1987, and 10% more than in 1997.
- Started
- 1.62 million
- Median new house price
- $152,5001998 $
- In one-family buildings
- 79%
- Before 1959 the counts are historical estimates: Historical Statistics of the United States reconstructed them from building permits and other records, in series that change method in 1920, 1930 and 1945. They leave out farm housing. The figures here were transcribed by hand from a scanned copy and checked against the table’s own totals.
- From 1959 the count is the Census Bureau’s privately owned housing units started; public housing is not in it. Mobile homes, conversions and temporary units are never counted.
- The median new house price is in the dollars of 1998, not adjusted for inflation.
Source US Census Bureau, Historical Statistics of the United States, Colonial Times to 1970, Series N 156 (1889–1958); New Residential Construction, annual housing starts (1959–2025); New Residential Sales, median sales price of new houses sold.
As built · new houses of 1998
The typical new house of 1998
How new single-family houses completed in 1998 across the US were built, from the US Census Bureau’s Survey of Construction. These describe that year’s new houses, not this one, and a house may have been altered since.
Showing the whole US · choose your state above, or a region here
New houses · 1998 · US
Most often: one story or two, on a slab or other foundation, vinyl siding outside, gas heat and air-conditioning.
- Median size
- 2,000sq ft
- Completed
- 1,160,000houses
Median size, sq ft
Floors
50% 2 stories or more (incl. 1½)
- 1 story48%
- 2 or more50%
- Split-level2%
- Floors are counted two ways: through 2008, 1 story, 2 or more, and split-level; from 2009, split-level and 1½-story houses count as 2 stories and 3 or more is separate. Only “1 story” is roughly comparable across the change.
2 or more, over time
Foundation
45% Slab or other (piers, pilings)
- Basement37%
- Slab or other45%
- Crawl space18%
- The Census counts slabs together with other foundations such as piers and pilings, so this is “slab or other”, never slab alone.
Slab or other, over time
Outside walls
37% Vinyl siding
- Brick21%
- Wood16%
- Stucco18%
- Vinyl siding37%
- Other8%
- Fiber cement was not counted separately until 2005. Before then it sits inside “other”.
- Aluminum siding is counted inside “other”, with block and stone.
Vinyl siding, over time
Heating fuel
70% Gas (natural or bottled)
- Gas70%
- Electricity26%
- Oil3%
- Other or none1%
- Gas includes bottled gas and propane as well as natural gas.
Gas (natural or bottled), over time
Heating system
72% Forced-air furnace
- Forced-air furnace72%
- Heat pump21%
- Hot water or steam4%
- Other or none3%
Forced-air furnace, over time
Air-conditioning
83% With air-conditioning
- With air-conditioning83%
- Without17%
With air-conditioning, over time
Bedrooms
55% 3 bedrooms
- 2 or fewer12%
- 355%
- 4 or more33%
3 bedrooms, over time
Bathrooms
41% 2 bathrooms
- 1½ or fewer8%
- 241%
- 2½34%
- 3 or more18%
2 bathrooms, over time
Garage
64% 2-car garage
- 1-car garage7%
- 2-car garage64%
- 3+ car garage15%
- Carport1%
- None12%
2-car garage, over time
Fireplaces
56% 1 fireplace
- None39%
- 156%
- 2 or more5%
1 fireplace, over time
- These are new single-family houses completed that year in that region, including houses built for rent. They describe how houses were being built, not any one house.
- Counts before 1999 include a 3.3 percent upward adjustment for houses built without permits in areas that issue permits, so house counts before and after 1999 are not strictly comparable.
- These are survey estimates. Sampling error is larger for older years, for single regions and for small categories; “withheld” marks cells the Census did not publish.
- Roofing is not recorded by this survey. Houses were not counted by state, so a region is the closest view.
Source US Census Bureau, Survey of Construction (Characteristics of New Housing), houses completed. Tables: Stories (2008 report), Foundation, Exterior Wall Material, Heating Fuel, Heating System, Air-Conditioning, Bedrooms, Bathrooms, Parking Facility, Fireplaces, Square feet.
As they stand today · houses built in the 1990s
Houses of the 1990s, today
The typical new house above is how houses were built in 1998. This is the other view: houses built in the 1990s that are still standing and lived in, as they are now, after decades of new roofs, new siding and renovation. Not as they were built.
Showing the whole US · detached single-family houses
Roofs today · built in the 1990s · US
About 4 in 5 surviving houses from the 1990s across the US have asphalt shingle roofs today, and about 1 in 12 has clay tile.
Roof material as reported in 2020. Most roofs have been replaced at least once since these houses were built, so this is what is on them now.
- Homes sampled
- 1,601
- Average size
- 2,490sq ft
- Asphalt shingles79%
- Metal6%
- Wood shakes3%
- Slate<0.5%
- Clay tile8%
- Concrete tile4%
- Other<0.5%
1,601 homes sampled · EIA RECS 2020
Asphalt shingles, by era built
The shell
Outside walls
44% Siding: vinyl, aluminum, fiber cement or steel
- Siding44%
- Brick20%
- Wood15%
- Stucco16%
- Stone1%
- Concrete block4%
- Other1%
1,601 homes sampled · EIA RECS 2020
Siding, by era built
Window glass
75% Double-pane
- Single-pane22%
- Double-pane75%
- Triple-pane2%
1,601 homes sampled · EIA RECS 2020
Double-pane, by era built
Foundation
43% Slab
- Full basement29%
- Part basement7%
- Crawl space21%
- Slab43%
- Other1%
3,665 homes sampled · AHS 2023
Slab, by era built
Stories
51% 1 story
- 1 story51%
- 2 stories44%
- 3 or more2%
- Split-level3%
1,601 homes sampled · EIA RECS 2020
1 story, by era built
Heating and cooling
Main heating fuel
48% Piped gas
- Gas48%
- Electricity41%
- Oil2%
- Propane6%
- Wood2%
- Other1%
3,665 homes sampled · AHS 2023
Piped gas, by era built
Main heating equipment
75% Forced warm-air furnace
- Furnace75%
- Boiler3%
- Heat pump15%
- Electric baseboard1%
- Wall or room heater3%
- Stove or fireplace1%
- Other or none2%
3,665 homes sampled · AHS 2023
Forced warm-air furnace, by era built
Air-conditioning
88% Central air
- Central air88%
- Room units only7%
- None5%
3,665 homes sampled · AHS 2023
Central air, by era built
The rooms
Bathrooms
35% Two full bathrooms
- No full bath<0.5%
- 16%
- 1½5%
- 235%
- 2½27%
- 3+28%
3,665 homes sampled · AHS 2023
Two full bathrooms, by era built
Fireplace
60% Usable fireplace
- Usable fireplace60%
- None40%
3,665 homes sampled · AHS 2023
Usable fireplace, by era built
Size
35% 2,500 sq ft or more
- Under 1,0004%
- 1,000–1,49916%
- 1,500–1,99924%
- 2,000–2,49921%
- 2,500+35%
3,531 homes sampled · AHS 2023
2,500 sq ft or more, by era built
Garage or carport
89% Garage or carport
- Garage or carport89%
- Neither11%
3,658 homes sampled · AHS 2023
Garage or carport, by era built
- Surviving detached single-family houses as they are today, by the decade their occupants say they were built. Roofs, siding, windows and heating include every replacement since. Houses that were torn down are not in it, so this is not how the era built.
- In the Census Bureau’s words, “some of the home characteristics … may have been more recent additions or installations and did not come with the home when it was originally built.”
- Survey estimates from samples of homes: a band with fewer than 30 sampled homes is never shown, and one with fewer than 100 is marked small sample. The EIA survey covers occupied primary homes only; the American Housing Survey also counts vacant ones.
Source US Energy Information Administration, Residential Energy Consumption Survey 2020, public microdata (roof, walls, window glass, stories, size); US Census Bureau and HUD, American Housing Survey 2023, national public use file (everything else); shares computed from the public microdata with the surveys’ weights. Caveat quoted from Census working paper 2011-18.
The year in context · the country
The country in 2000
From the 2000 census, the one nearest 1998. These describe every home standing at the time, old and new, not houses built that year.
| Fact | US |
|---|---|
| Main house heating fuelsoccupied homesCensus, house heating fuel | utility gas 51.2%electricity 30.3%oil or kerosene 9.0%bottled gas 6.5% |
| Homes owned by the people living in themCensus, homeownership | 66.2% |
| Homes built in the 1990s still standing todayACS 2020-2024, B25034 | 17.8 million 12.4% of homes |
| Half of all homes standing today were built beforethe median year builtACS 2020-2024, B25035 | 1980 |
Census figures are shares of homes counted in 2000. Today’s count is the US Census Bureau’s American Community Survey, 2020 to 2024, which includes vacant homes and dates them by what residents report. Choose your state above to see it beside the US.
See something in the 1998 report that looks wrong?Report an error on this page