Often present · Fire & life safety
Yellow CSST gas tubing without bonding
Flexible yellow stainless-steel gas tubing can be damaged by a nearby lightning strike, and older installs may lack the bonding wire that reduces the risk.
- Houses built
- 1990–2011
- Dates from
- Approximate era: Dates are an approximate era drawn from trade and reference sources.
- How common
- No reliable count exists
- Priority
- Worth a look
- Mainly about
- Safety
- Where to look
- Basement & foundation · Attic · Heating & cooling · Water heater
What it is
Corrugated stainless steel tubing (CSST) in a yellow jacket is a flexible gas piping used in houses. A class action against its makers covered tubing installed in homes as of September 5, 2006, and many local codes require bonding the tubing to the electrical ground. Houses built before bonding became routine may not have it.
How sure the dates are
Approximate era: Dates are an approximate era drawn from trade and reference sources.Dates are an approximate era drawn from trade and reference sources. What the labels mean
How common it is
No reliable count existsIt applies only to houses with gas service.
The years
Houses built from 1990 to 2011 may have it.
- Earliest
- About 1990An approximate date. It came in gradually, and sources differ by a few years.
- Most likely
- Not narrowedSources give no narrower window, so treat every year in the range alike.
- Latest
- About 2011An approximate date. The change came gradually, so a few later houses may have it.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
How to check
Look at exposed gas piping in the basement, attic, crawl space or at the furnace and water heater: flexible corrugated tubing in a yellow jacket is CSST (black-jacketed tubing is a newer type).
Look for bonding: a clamp on a rigid gas fitting with a bare or green copper wire running to the electrical panel or grounding system.
- Basement & foundation
- Attic
- Heating & cooling
- Water heater
What to do
If you find itIf you have yellow CSST and see no bonding wire, have a licensed electrician bond it following the tubing maker's instructions and current code. It is a small job.
Sources
2 verified sources. Each quote is copied word for word from the page linked.
InterNACHI, Lightning: Facts & DangersTrade reference
nachi.org/lightning.htm (opens in a new tab)class-action lawsuit against manufacturers of CCST (Titeflex, Ward, OmegaFlex and Parker Hannifin) installed in homes as of September 5, 2006
Wikipedia, Corrugated stainless steel tubing (article lacks inline citations)Reference
en.wikipedia.org/wiki/Corrugated_stainless_steel_tubing (opens in a new tab)Yellow-jacketed CSST should be bonded (connected to the electrical service panel's ground bus) at its entrance into a building. Many local codes require this.
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.