Year Built

Report · houses built in

What a house built in 2011 often has

Age
15yrs
On record
11
Check first
1
Built without
1

Choose one to hide issues that only apply elsewhere.

About your house

A few optional answers make this report specific to one house.

0 of 11 questions answered.

Headline findingCheck first

Gree-made dehumidifiers (2013 recall)

2005–2013Court record: Dates come from a court settlement or a product recall.

About 2.5 million dehumidifiers sold from 2005 to 2013 under 13 brand names, including Frigidaire, Kenmore and GE, can overheat and catch fire.

Gree-made dehumidifiers (2013 recall): 2005–2013; the line is 2011.

11 things on record apply to a 2011 house: 1 to check first, 1 protection it was built without, and 9 more by part of the house.

Where 2011 sits among every issue on record

Point at a band to read it · drag or use the arrow keys to compare years
What the 2011 line crosses11 bands
Electrical
Nothing for 2011
Plumbing
Nothing for 2011
Hazardous materials
Nothing for 2011
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

Check these first

The item most worth a look in a 2011 house: safety first, then cost.

  1. Check firstOften present

    Gree-made dehumidifiers (2013 recall)

    About 2.5 million dehumidifiers sold from 2005 to 2013 under 13 brand names, including Frigidaire, Kenmore and GE, can overheat and catch fire.

    How to checkBasement & foundation
    1. Look in the basement, crawlspace entry and laundry area for a portable dehumidifier.
    2. Read the brand and pint capacity on the front.
    3. Find the sticker with the model number and date code on the back, front or side of the unit.
    4. Compare the model and date code with the tables on the CPSC recall notice. Many Gree and SoleusAir models are listed as all units.

    If you find itIf it matches, unplug it and stop using it. The remedy was a refund from Gree, not a repair; check the recall notice for whether refunds are still offered.

    How commonAbout 2.2 million units were recalled in the US in 2013, rising to about 2.5 million with the GE-brand expansion; no count of affected homes exists.

    Keep in mindA dehumidifier is a portable appliance, so it may have come with the house or been bought later for a house of any age. A separate 2023 Gree recall covers other models made 2011 to 2014.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 9 sources →

    2005–2013

    Court record: Dates come from a court settlement or a product recall.No reliable count exists

Built without

Protections that became standard after 2011. A house keeps what it was built with unless someone added them, and many have been.

  • Built before mandatory airtightness testing (2012 energy code)

    Built 2015 or earlierThe 2012 energy code was the first to make new houses pass a whole-house air leakage test.

    The 2012 energy code was the first to make new houses pass a whole-house air leakage test.

    Read the full entry →

    Built 2015 or earlier

    Federal rule: Dates come from a federal rule or a model building code.Likely

    How to check

    1. Look near the electrical panel or furnace for an energy code certificate or a posted blower-door test result.
    2. Ask the seller or builder whether a blower-door test or energy rating was done.
    3. Notice drafts around outlets, attic hatches, recessed lights and window trim on a cold or windy day.

    If you find itNothing is required. If the house feels drafty or bills are high, an energy audit with a blower-door test shows where air sealing would help most.

    How commonHouses built before their state adopted the 2012 code were not required to pass this test. Adoption dates by state were not researched.

    Keep in mindThis is a model code. States and cities adopted it at different times, so the end year here is stretched a few years and is soft. Check your state's adoption date.

    Details and 3 sources →

Everything else, by part of the house

Materials and products often installed in 2011. Open any row for how to check.

Where to look. Each number counts the items in this report for that part of the house.

Plumbing & water1

  • Coaire and Quietside tankless water heaters (2014 recall, no remedy)

    2008–2014These tankless water heaters sold from 2008 to 2014 can overheat, and the maker is gone, so there is no fix on offer.

    These tankless water heaters sold from 2008 to 2014 can overheat, and the maker is gone, so there is no fix on offer.

    Read the full entry →

    2008–2014

    Court record: Dates come from a court settlement or a product recall.No reliable count exists

    How to check

    1. Look for a white wall-mounted tankless heater about 25 to 28 inches tall.
    2. Check for 'S-Line Condensing' on the top front.
    3. Check for the brand 'Coaire' or 'Quietside' on the bottom front.

    If you find itIf it matches, stop using it and have it replaced. CPSC says the firm is no longer in business, a remedy is no longer available, and the heater should be disposed of.

    How commonAbout 29,000 units were recalled in the US; no count of affected homes exists.

    Keep in mindTankless heaters are often installed as replacements, so one could be in a house of any age.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 5 sources →

Kitchen & bath1

  • Kidde plastic-handle fire extinguishers (2017 recall)

    1973–2017Kidde recalled about 37.8 million fire extinguishers because some may not spray when you need them.

    Kidde recalled about 37.8 million fire extinguishers because some may not spray when you need them.

    Read the full entry →

    1973–2017

    Court record: Dates come from a court settlement or a product recall.No reliable count exists

    How to check

    1. Look under the kitchen sink, in the pantry, garage and utility room for any Kidde extinguisher.
    2. Note whether it has a plastic handle (red, white or silver models) or a push-button Pindicator top.
    3. Read the model number on the label and compare it with the model list on the CPSC recall notice.
    4. On units made in 2007 or later, a 10-digit date code is printed on the side of the cylinder near the bottom.

    If you find itIf the model is on the list, replace it and contact Kidde through the product safety recall page on kidde.com. Check the recall notice for whether the replacement offer is still open.

    How commonAbout 37.8 million units were recalled in the US; no count of affected homes exists.

    Keep in mindExtinguishers are bought, not built in, so the year a house was built predicts little: owners add them to houses of every age. The recall did not cover every Kidde extinguisher, only the listed models.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →

Heating, cooling & chimney1

  • R-410A air conditioners and heat pumps

    2010–2025 · peakCentral AC installed from about 2010 to 2025 may well run on R-410A, a refrigerant that new equipment is now moving away from.

    Central AC installed from about 2010 to 2025 may well run on R-410A, a refrigerant that new equipment is now moving away from.

    Read the full entry →

    2010–20252011 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.Likely

    How to check

    1. Find the nameplate on the outdoor unit.
    2. Look for the refrigerant listed: R-410A, R-22, or a newer type such as R-454B or R-32.

    If you find itNothing is required for a working system. When it is time to replace it, ask the contractor which refrigerant the new system uses and whether any other parts need changing.

    How commonNo count of homes exists. EPA barred making new equipment with R-22 from January 1, 2010; that most systems since then use R-410A is an inference, not a sourced figure.

    Keep in mindThe 2010 start is approximate. EPA's installation rules depend on when a system's parts were made, so check EPA's current page before relying on a cutoff. Many older houses got an R-410A system as a replacement.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →

Roof & attic1

  • Factory-built roof trusses

    Built 1955 or laterIf your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.

    If your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.

    Read the full entry →

    Built 1955 or later

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. In the attic, look for diagonal 2x4s forming W or M shapes, joined by toothed galvanized steel plates.
    2. Rafters, by contrast, are larger boards running from the ridge to the wall with open space between.
    3. Look for cut or notched members and plates that have backed out of the wood.

    If you find itNothing is needed unless trusses are damaged or altered. Before any attic conversion, skylight or other change that touches a truss, get an engineer's design.

    How commonNo reliable count exists for houses by year built.

    Keep in mindTruss use grew over decades, and many houses still use rafters, especially custom homes and complex roofs. A reference source dates the connector plate to 1955.

    Details and 1 source →

Foundation & basement4

  • Gree-made dehumidifiers (2023 recall, made 2011-2014)

    2011–2014A second Gree dehumidifier recall in 2023 covered models that the 2013 list missed.

    A second Gree dehumidifier recall in 2023 covered models that the 2013 list missed.

    Read the full entry →

    2011–2014

    Court record: Dates come from a court settlement or a product recall.No reliable count exists

    How to check

    1. Look for a portable dehumidifier in the basement, crawlspace entry or laundry area.
    2. Check the brand: Kenmore, GE, SoleusAir, Norpole or Seabreeze.
    3. Read the model number on the unit's label and compare it with the 42 models on the 2023 CPSC notice, which include Kenmore 407.53530310 and GE ADEH50LPQ1.

    If you find itIf it matches, unplug it and stop using it. The notice offers a refund from Gree; check the notice for current details.

    How commonAbout 1.56 million units were recalled; no count of affected homes exists.

    Keep in mindThis is a portable appliance that owners buy for houses of any age, so build year is only a rough guide. The 2023 and 2013 recall lists are separate, and one unit may need checking against both.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 5 sources →
  • Yellow CSST gas tubing without bonding

    1990–2011Flexible yellow stainless-steel gas tubing can be damaged by a nearby lightning strike, and older installs may lack the bonding wire that reduces the risk.

    Flexible yellow stainless-steel gas tubing can be damaged by a nearby lightning strike, and older installs may lack the bonding wire that reduces the risk.

    Read the full entry →

    1990–2011

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. Look at exposed gas piping in the basement, attic, crawl space or at the furnace and water heater: flexible corrugated tubing in a yellow jacket is CSST (black-jacketed tubing is a newer type).
    2. Look for bonding: a clamp on a rigid gas fitting with a bare or green copper wire running to the electrical panel or grounding system.

    If you find itIf you have yellow CSST and see no bonding wire, have a licensed electrician bond it following the tubing maker's instructions and current code. It is a small job.

    How commonNo reliable count exists. It applies only to houses with gas service.

    Keep in mindThe start year and the code year that made bonding mandatory were not confirmed, and states adopted codes at different times. CSST is still installed today, with bonding.

    Details and 2 sources →
  • Crumbling concrete foundations (pyrrhotite)

    1983–2015CT MAIn parts of north-central Connecticut and central Massachusetts, some foundations poured with local quarry stone are crumbling because of a mineral called pyrrhotite.

    In parts of north-central Connecticut and central Massachusetts, some foundations poured with local quarry stone are crumbling because of a mineral called pyrrhotite.

    Read the full entry →

    1983–2015

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. In the basement, look at the foundation walls for horizontal cracks and map-pattern (spider-web) cracking.
    2. Look for white powdery deposits, rust-brown staining and flaking.
    3. A clean-looking wall does not rule it out; a licensed engineer's visual inspection and a core sample tested for pyrrhotite confirm it.

    If you find itIf you are in an affected area, have a licensed engineer inspect the foundation, especially before buying, and check with your state about any current testing or repair assistance.

    How commonNo reliable count exists. The problem is tied to aggregate from certain local quarries, so it is limited to parts of central Connecticut and Massachusetts.

    Keep in mindThe 1983 to 2015 window comes from state officials' figures that could not be independently confirmed, and only towns near the source quarries are affected. Most houses in Connecticut and Massachusetts are not at risk.

    Details and 2 sources →
  • Engineered I-joist floors

    Built 1970 or later · peakBy 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.

    By 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.

    Read the full entry →

    Built 1970 or later2011 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.Possible

    How to check

    1. Look up at the basement or garage ceiling for I-shaped joists: a thin OSB or plywood web with small lumber flanges top and bottom.
    2. They are usually printed with the maker's brand name.
    3. If you can see them, they are unprotected from below.

    If you find itConsider covering exposed I-joists with drywall, and make sure working smoke alarms cover every level, including the basement.

    How commonWikipedia: about 50% of wood light-frame floors used I-joists as of 2005.

    Keep in mindNewer model codes are reported to require covering them, but that was not confirmed and code adoption varies by state. The hazard applies only where the joists are exposed.

    Details and 2 sources →

Whole house1

  • Home fire sprinklers

    Built 2011 or laterCACalifornia has required fire sprinklers in new one- and two-family homes since 2011, so newer California houses generally have small sprinkler heads in the ceilings.

    California has required fire sprinklers in new one- and two-family homes since 2011, so newer California houses generally have small sprinkler heads in the ceilings.

    Read the full entry →

    Built 2011 or later

    Federal rule: Dates come from a federal rule or a model building code.Likely

    How to check

    1. Look up: small sprinkler heads, often under flat white cover plates, in the ceiling of every room.
    2. Find the riser, a pipe with a gauge and flow switch, near the water main or in the garage.

    If you find itKeep the control valve open and never paint over a sprinkler head. Replace any head that has been painted or blocked.

    How commonCalifornia has required sprinklers in all new residential construction since 2011 (Wikipedia). Outside places that require them, they are uncommon in houses.

    Keep in mindSome cities outside California also require sprinklers by local ordinance. Houses permitted before 2011 but finished later may not have them.

    Details and 2 sources →

What’s due at this age

A 2011 house is 15 years old. Here is where its parts stand against their typical life, and which ones have certainly been replaced by now.

In their window
17
Past life, if original
7
Due within 5 yrs
6
Replaced by now
4

4 of the 53 parts we track wear out so much faster than a 2011 house has stood that they have been replaced at least once. Know when something was last replaced? Enter the year (or a decade, like 2010s) and we’ll show where that part stands. It stays on this device only.

In the replacement window now

17

If these are still the originals, they are inside their typical service life range. Worth budgeting for.

  • Central air conditionerHeating & cooling · lasts 7–15 yrs

    Hot or coastal climates and neglected filters shorten life. Weak cooling, ice on the lines and frequent repairs are the signs.

    7–15 yrsIn its windowif original
  • Electric rangeKitchen · lasts 13–15 yrs

    Burner elements and switches can be replaced, so age alone is not a reason to scrap it. Scorched or cracked elements should be replaced.

    13–15 yrsIn its windowif original
  • Garage door openerGarage · lasts 10–15 yrs

    Quality and how often it is used set the life. Test the auto-reverse by laying a board on the floor under the door; an opener that fails to reverse needs replacing.

    10–15 yrsIn its windowif original
  • Heat pumpHeating & cooling · lasts 10–15 yrs

    A heat pump runs for both heating and cooling. Yearly service and clean coils help.

    10–15 yrsIn its windowif original
  • Tank water heaterWater heater · lasts 6–15 yrs

    Mineral-rich water shortens life. Rust at the base, moisture in the pan or rumbling mean it is failing, and a burst tank can flood the area, so replace one past its range before it leaks.

    6–15 yrsIn its windowif original
  • Washing machineBathroom · lasts 5–15 yrs

    Wide range because use varies. Leaks, violent shaking and rust-colored water mean it is failing; check the supply hoses and drain pan.

    5–15 yrsIn its windowif original
  • Well pumpWater pipes · lasts ~15 yrs

    Sediment and frequent cycling shorten life. Short cycling, low pressure or spitting air mean the pump or pressure tank is in trouble.

    ~15 yrsIn its windowif original
  • Wood deck boardsDeck & yard · lasts ~15 yrs

    Sun and moisture decide it. Soft spots, splitting and loose boards are the sign.

    ~15 yrsIn its windowif original
  • Gas rangeKitchen · lasts 15–17 yrs

    Burners and igniters wear first.

    15–17 yrsIn its windowif original
  • Aluminum windowsWindows · lasts 15–20 yrs

    Corroded tracks and failed seals are common. They also conduct heat and cold, so old ones are costly to run.

    15–20 yrsIn its windowif original
  • Asphalt drivewayDeck & yard · lasts 15–20 yrs

    Cracks let water in, which freezing then widens. Sealing and crack repair extend the life.

    15–20 yrsIn its windowif original
  • Faucets and spray hoseBathroom · lasts 15–20 yrs

    Drips and stiff handles mean worn cartridges or seals. A fix is usually cheap.

    15–20 yrsIn its windowif original
  • Tankless water heaterWater heater · lasts 10–20 yrs

    Scale buildup from hard water is the main enemy; periodic descaling helps it reach the long end. Sources differ widely, so treat the range as a guide.

    10–20 yrsIn its windowif original
  • Flat roof (EPDM rubber)Roof · lasts 15–25 yrs

    Seams, edges and penetrations leak first. Ponding water and punctures from foot traffic shorten life.

    15–25 yrsIn its windowif original
  • Forced-air furnaceHeating & cooling · lasts 15–25 yrs

    CPSC lists a breached heat exchanger, vent or chimney among the failures in furnace carbon monoxide incidents, and advises a professional inspection of fuel-burning heating every year. Keep a working CO alarm nearby. Frequent repairs and rising bills are signs of age.

    15–25 yrsIn its windowif original
  • Deck framingDeck & yard · lasts 10–30 yrs

    Check for hidden rot where the ledger meets the house and at the posts. A deck that bounces or sways should be checked before anyone uses it.

    10–30 yrsIn its windowif original
  • Septic systemDrains & sewer · lasts 15–40 yrs

    Regular pumping and inspection extend life; the drainfield usually fails first. Slow drains, odors and wet or unusually green ground over the drainfield are the warning signs.

    15–40 yrsIn its windowif original

Past typical life, if still original

7

Older than the usual range, but not so old that an original is unlikely. Worth finding out whether they have been replaced.

  • Clothes dryerWhole house · lasts ~13 yrs
    ~13 yrs2 yrs pastif original
  • RefrigeratorKitchen · lasts 9–13 yrs
    9–13 yrs2 yrs pastif original
  • Garbage disposalKitchen · lasts ~12 yrs
    ~12 yrs3 yrs pastif original
  • CarpetWalls, ceilings & floors · lasts 8–10 yrs
    8–10 yrs5 yrs pastif original
  • Caulking (interior and exterior)Exterior walls · lasts 5–10 yrs
    5–10 yrs5 yrs pastif original
  • Exterior paintExterior walls · lasts 7–10 yrs
    7–10 yrs5 yrs pastif original
  • Smoke alarmWhole house · lasts ~10 yrs
    ~10 yrs5 yrs pastif original

Coming due in the next five years

6

Not yet, but close enough to plan for.

  • Aluminum gutters and downspoutsRoof · lasts 20–40 yrs
    20–40 yrsIn 5 yrsif original
  • Asphalt shingle roof (3-tab)Roof · lasts ~20 yrs
    ~20 yrsIn 5 yrsif original
  • Flat roof (modified bitumen)Roof · lasts ~20 yrs
    ~20 yrsIn 5 yrsif original
  • Garage doorGarage · lasts 20–25 yrs
    20–25 yrsIn 5 yrsif original
  • Vinyl or fiberglass windowsWindows · lasts 20–40 yrs
    20–40 yrsIn 5 yrsif original
  • Water softenerWater pipes · lasts ~20 yrs
    ~20 yrsIn 5 yrsif original
Replaced at least once by now: find out when4

A 2011 house has outlasted these parts’ typical life at least once over, so what matters is when each was last replaced. Ask the seller or check receipts and date labels; enter a year and the part moves up to where it stands.

  • Carbon monoxide alarmWhole houselasts ~5 yrs≈3 lifetimes
  • Dryer vent (plastic)Whole houselasts ~5 yrs≈3 lifetimes
  • Sump pumpBasement & foundationlasts ~7 yrs≈2 lifetimes
  • DishwasherKitchenlasts ~9 yrs≈1 lifetimes
Further out19
  • Vinyl floorWalls, ceilings & floorslasts ~25 yrsin 10 yrs
  • Wood shake roofRooflasts ~25 yrsin 10 yrs
  • Asphalt shingle roof (architectural)Rooflasts ~30 yrsin 15 yrs
  • GFCI outletsKitchenlasts ~30 yrsin 15 yrs
  • Wood windowsWindowslasts ~30 yrsin 15 yrs
  • Boiler (hot-water or steam)Heating & coolinglasts ~40 yrsin 25 yrs
  • Chimney flue tileChimneylasts 40–120 yrsin 25 yrs
  • Concrete walkwayDeck & yardlasts 40–50 yrsin 25 yrs
  • Metal roofRooflasts 40–80 yrsin 25 yrs
  • Cast-iron drain pipe (below ground)Drains & sewerlasts 50–60 yrsin 35 yrs
  • Copper water supply linesWater pipeslasts 50–70 yrsin 35 yrs
  • Electrical service panelElectrical panellasts ~60 yrsin 45 yrs
  • Heating and cooling ductworkHeating & coolinglasts 60–100 yrsin 45 yrs
  • Vinyl sidingExterior wallslasts ~60 yrsin 45 yrs
  • Clay or concrete tile roofRooflasts ~100 yrsin 85 yrs
  • Fiber cement sidingExterior wallslasts ~100 yrsin 85 yrs
  • Fiberglass exterior doorWhole houselasts ~100 yrsin 85 yrs
  • Hardwood floorWalls, ceilings & floorslasts ~100 yrsin 85 yrs
  • ToiletsBathroomlasts ~100 yrsin 85 yrs

Typical lives from InterNACHI Standard Estimated Life Expectancy Chart for Homes, CPSC, U.S. Department of Energy (hosted guide), US Department of Energy, Energy Saver Guide (2022), InterNACHI, Smoke Alarm Inspection, US EPA, New Homebuyer's Guide to Septic Systems, InterNACHI and U.S. Consumer Product Safety Commission. Real lives vary with climate, quality and upkeep.

Your place

Add a ZIP code for a few sourced facts about where the house stands: the homes around it, radon, climate and flood maps. All optional.

Looking up a ZIP code needs JavaScript. Everything else on this page works without it.

Part two

The year in context

What was changing around 2011, how much the country was building, how houses of this era stand today and what homes were like then. All of it describes houses in general, never this one.

The year in context · events

Around 2011: what was changing in homebuilding

What happened in 2011 first, then the nearest dated events within 3 years either side. Each comes with its source and how strong that source is.

5 events on a 2007–2015 axis; the tagged line is 2011. Filled rings are dated to 2011. Dashed rings are approximate (circa).

In 2011

  1. 2011

    Plumbing

    Lead-free definition tightened to 0.25 percent

    In 2011 Congress passed the Reduction of Lead in Drinking Water Act lowering the lead content of wetted plumbing surfaces from 8 percent to a weighted average of 0.25 percent.

    U.S. Environmental Protection AgencyPrimary source
    Quote
    “In 2011 Congress passed the Reduction of Lead in Drinking Water Act (RLDWA) revising the definition of lead free” U.S. Environmental Protection Agency

Nearby, 2008 to 2014within 3 years of 2011

  1. 2001–2009

    Materials

    Imported Chinese drywall used in houses

  2. 2008

    Policy

    EPA lead renovation, repair and painting rule

    EPA's 2008 RRP Rule, amended in 2010 and 2011, requires lead-safe work practices and certified renovators for paid work disturbing paint in homes built before 1978.

    U.S. Environmental Protection AgencyPrimary source
    Quote
    “EPA’s 2008 Lead-Based Paint Renovation, Repair and Painting (RRP) Rule (as amended in 2010 and 2011)” U.S. Environmental Protection Agency
  3. 2010

    Industry

    New single-family completions fall to 496 thousand

    After the housing collapse only 496 thousand new single-family houses were completed in 2010, versus 1,636 thousand in 2005; heat pumps were in 38 percent of them.

    U.S. Census Bureau, Characteristics of New Housing 2017 (annual tables)Primary source
    Quote
    “2010 496 279 189 12 16 100 56 38 2 3” U.S. Census Bureau, Characteristics of New Housing 2017 (annual tables)
  4. 2014

    Electrical

    Arc-fault protection extended to most residential outlets

    The National Electrical Code has required arc-fault protection for most residential outlets since 2014.

    WikipediaReference
    Quote
    “the US National Electrical Code has required them to protect most residential outlets since 2014” Wikipedia

Events come from a researched timeline of 150 dated changes to US homebuilding, each checked against the quoted source. Primary source is a government or standards body, Trade reference a trade body and Reference a general reference such as Wikipedia. A date is when something began or became required, not when every builder followed.

The year in context · building

Housing that year

How many new homes were started across the US in 2011, against every year since 1889. It is the whole country’s building, houses and apartments, not a count of houses like this one.

New homes started · 2011 · US

About 609,000 new homes (houses and apartments) were started in 2011, well below the long-run median of about 1.1 million a year, and 4% more than in 2010.

Started
609,000
Median new house price
$227,2002011 $
In one-family buildings
71%
  • Before 1959 the counts are historical estimates: Historical Statistics of the United States reconstructed them from building permits and other records, in series that change method in 1920, 1930 and 1945. They leave out farm housing. The figures here were transcribed by hand from a scanned copy and checked against the table’s own totals.
  • From 1959 the count is the Census Bureau’s privately owned housing units started; public housing is not in it. Mobile homes, conversions and temporary units are never counted.
  • The median new house price is in the dollars of 2011, not adjusted for inflation.

Source US Census Bureau, Historical Statistics of the United States, Colonial Times to 1970, Series N 156 (1889–1958); New Residential Construction, annual housing starts (1959–2025); New Residential Sales, median sales price of new houses sold.

As built · new houses of 2011

The typical new house of 2011

How new single-family houses completed in 2011 across the US were built, from the US Census Bureau’s Survey of Construction. These describe that year’s new houses, not this one, and a house may have been altered since.

Showing the whole US · choose your state above, or a region here

Region

New houses · 2011 · US

Most often: two stories, on a slab or other foundation, vinyl siding outside, gas heat and air-conditioning.

Median size
2,233sq ft
Completed
447,000houses

Median size, sq ft

  1. Floors

    50% 2 stories (incl. 1½ and split-level)

    • 1 story46%
    • 2 stories50%
    • 3 or more4%
    • Floors are counted two ways: through 2008, 1 story, 2 or more, and split-level; from 2009, split-level and 1½-story houses count as 2 stories and 3 or more is separate. Only “1 story” is roughly comparable across the change.

    2 stories, over time

  2. Foundation

    53% Slab or other (piers, pilings)

    • Basement30%
    • Slab or other53%
    • Crawl space17%
    • The Census counts slabs together with other foundations such as piers and pilings, so this is “slab or other”, never slab alone.

    Slab or other, over time

  3. Outside walls

    34% Vinyl siding

    • Brick24%
    • Wood8%
    • Stucco17%
    • Vinyl siding34%
    • Fiber cement15%
    • Other2%
    • Aluminum siding is counted inside “other”, with block and stone.

    Vinyl siding, over time

  4. Heating fuel

    55% Gas (natural or bottled)

    • Gas55%
    • Electricity43%
    • Oil1%
    • Other or none2%
    • Gas includes bottled gas and propane as well as natural gas.

    Gas (natural or bottled), over time

  5. Heating system

    56% Forced-air furnace

    • Forced-air furnace56%
    • Heat pump38%
    • Hot water or steam2%
    • Other or none4%

    Forced-air furnace, over time

  6. Air-conditioning

    88% With air-conditioning

    • With air-conditioning88%
    • Without12%

    With air-conditioning, over time

  7. Bedrooms

    48% 3 bedrooms

    • 2 or fewer13%
    • 348%
    • 4 or more39%

    3 bedrooms, over time

  8. Bathrooms

    34% 2 bathrooms

    • 1½ or fewer8%
    • 234%
    • 2½31%
    • 3 or more28%

    2 bathrooms, over time

  9. Garage

    62% 2-car garage

    • 1-car garage6%
    • 2-car garage62%
    • 3+ car garage18%
    • Carport1%
    • None13%

    2-car garage, over time

  10. Fireplaces

    50% No fireplace

    • None50%
    • 144%
    • 2 or more6%

    No fireplace, over time

  • These are new single-family houses completed that year in that region, including houses built for rent. They describe how houses were being built, not any one house.
  • These are survey estimates. Sampling error is larger for older years, for single regions and for small categories; “withheld” marks cells the Census did not publish.
  • Roofing is not recorded by this survey. Houses were not counted by state, so a region is the closest view.

Source US Census Bureau, Survey of Construction (Characteristics of New Housing), houses completed. Tables: Stories, Foundation, Exterior Wall Material, Heating Fuel, Heating System, Air-Conditioning, Bedrooms, Bathrooms, Parking Facility, Fireplaces, Square feet.

As they stand today · houses built 2010 or later

Houses of 2010 or later, today

The typical new house above is how houses were built in 2011. This is the other view: houses built 2010 or later that are still standing and lived in, as they are now, after decades of new roofs, new siding and renovation. Not as they were built.

Showing the whole US · detached single-family houses

Region

Roofs today · built 2010 to 2015 · US

About 4 in 5 surviving houses built 2010 to 2015 across the US have asphalt shingle roofs today, and about 1 in 12 has clay tile.

Roof material as reported in 2020. Most roofs have been replaced at least once since these houses were built, so this is what is on them now.

Homes sampled
586
Average size
2,708sq ft
  • Asphalt shingles80%
  • Metal4%
  • Wood shakes5%
  • Slate1%
  • Clay tile8%
  • Concrete tile2%
  • Other1%

586 homes sampled · EIA RECS 2020

Asphalt shingles, by era built

Roof, walls, window glass and stories come from the EIA survey, which can only group houses built 2010 to 2015. Everything else comes from the American Housing Survey’s finer band: houses built 2010 or later.

The shell

  1. Outside walls

    41% Siding: vinyl, aluminum, fiber cement or steel

    • Siding41%
    • Brick26%
    • Wood8%
    • Stucco18%
    • Stone4%
    • Concrete block3%
    • Other1%

    586 homes sampled · EIA RECS 2020

    Siding, by era built

  2. Window glass

    85% Double-pane

    • Single-pane13%
    • Double-pane85%
    • Triple-pane2%

    586 homes sampled · EIA RECS 2020

    Double-pane, by era built

  3. Foundation

    58% Slab

    • Full basement23%
    • Part basement4%
    • Crawl space14%
    • Slab58%
    • Other1%

    2,654 homes sampled · AHS 2023

    Slab, by era built

  4. Stories

    52% 1 story

    • 1 story52%
    • 2 stories45%
    • 3 or more2%
    • Split-level1%

    586 homes sampled · EIA RECS 2020

    1 story, by era built

Heating and cooling

  1. Main heating fuel

    50% Electricity

    • Gas42%
    • Electricity50%
    • Oil1%
    • Propane6%
    • Wood1%
    • Other1%

    2,654 homes sampled · AHS 2023

    Electricity, by era built

  2. Main heating equipment

    76% Forced warm-air furnace

    • Furnace76%
    • Boiler1%
    • Heat pump17%
    • Electric baseboard1%
    • Wall or room heater3%
    • Stove or fireplace1%
    • Other or none1%

    2,654 homes sampled · AHS 2023

    Forced warm-air furnace, by era built

  3. Air-conditioning

    94% Central air

    • Central air94%
    • Room units only3%
    • None3%

    2,654 homes sampled · AHS 2023

    Central air, by era built

The rooms

  1. Bathrooms

    40% Three or more

    • No full bath<0.5%
    • 14%
    • 1½2%
    • 228%
    • 2½26%
    • 3+40%

    2,654 homes sampled · AHS 2023

    Three or more, by era built

  2. Fireplace

    51% No usable fireplace

    • Usable fireplace49%
    • None51%

    2,654 homes sampled · AHS 2023

    No usable fireplace, by era built

  3. Size

    45% 2,500 sq ft or more

    • Under 1,0002%
    • 1,000–1,49910%
    • 1,500–1,99922%
    • 2,000–2,49921%
    • 2,500+45%

    2,539 homes sampled · AHS 2023

    2,500 sq ft or more, by era built

  4. Garage or carport

    94% Garage or carport

    • Garage or carport94%
    • Neither7%

    2,642 homes sampled · AHS 2023

    Garage or carport, by era built

  • Surviving detached single-family houses as they are today, by the decade their occupants say they were built. Roofs, siding, windows and heating include every replacement since. Houses that were torn down are not in it, so this is not how the era built.
  • In the Census Bureau’s words, “some of the home characteristics … may have been more recent additions or installations and did not come with the home when it was originally built.”
  • Survey estimates from samples of homes: a band with fewer than 30 sampled homes is never shown, and one with fewer than 100 is marked small sample. The EIA survey covers occupied primary homes only; the American Housing Survey also counts vacant ones.

Source US Energy Information Administration, Residential Energy Consumption Survey 2020, public microdata (roof, walls, window glass, stories, size); US Census Bureau and HUD, American Housing Survey 2023, national public use file (everything else); shares computed from the public microdata with the surveys’ weights. Caveat quoted from Census working paper 2011-18.

The year in context · the country

The country’s homes today

The decennial census stopped collecting these details after 2000, so for a house built in 2011 there is only today’s count.

Housing facts, the US
FactUS
Homes built in the 2010s still standing todayACS 2020-2024, B2503413.6 million 9.4% of homes
Half of all homes standing today were built beforethe median year builtACS 2020-2024, B250351980

Today’s count is the US Census Bureau’s American Community Survey, 2020 to 2024, which includes vacant homes and dates them by what residents report. Choose your state above to see it beside the US.

See something in the 2011 report that looks wrong?Report an error on this page