Problem drywall (Chinese drywall)

Some houses built or renovated from 2001 to 2009, mostly in Florida and the Gulf states, got imported drywall that gives off sulfur gases and blackens copper.

Houses built
2001–2009
Dates from
Court record: Dates come from a court settlement or a product recall.
How common
Rare
Priority
Check first
Mainly about
Safety
Where to look
Walls, ceilings & floors · Heating & cooling · Wiring & outlets · Attic

What it is

CPSC has about 4,051 reports of problem drywall from 44 states, and early reports came overwhelmingly from Florida, Louisiana, Mississippi, Alabama and Virginia. The gases corrode air-conditioner coils, wiring and gas fittings. Federal remediation guidance amounts to a gut renovation: remove the drywall and replace wiring components, alarms and some gas piping.

How sure the dates are

Court record: Dates come from a court settlement or a product recall.

Dates come from a court settlement or a product recall. What the labels mean

How common it is

Rare

CPSC has about 4,051 reports. In March 2010, over 90% came from Florida (59%), Louisiana (20%), Mississippi (6%), Alabama (5%) and Virginia (4%). Even there it is a small share of houses built in these years.

The years

Houses built from 2001 to 2009 may have it. It is most likely in houses built 2005 to 2008.

Earliest
About 2001An approximate date. It came in gradually, and sources differ by a few years.
Most likely
2005–2008The years it is most common: the solid part of the band.
Latest
About 2009An approximate date. The change came gradually, so a few later houses may have it.
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

Regional

This applies to houses in Florida, Louisiana, Mississippi, Alabama and Virginia, not nationwide. Reports hide it when you choose another state.

How to check

  1. Look at the copper tubing on the air conditioner's indoor coil: blackened copper, not green, is CPSC's warning sign. An electrician can check the bare ground wires in outlet and switch boxes for the same thing.

  2. Note any sulfur or rotten-egg smell, or repeated air-conditioner coil failures.

  3. In the attic, look at the back of exposed drywall for Chinese manufacturer markings.

  4. A lab test of the drywall or the copper corrosion confirms it.

Where to look
  • Walls, ceilings & floors
  • Heating & cooling
  • Wiring & outlets
  • Attic

What to do

If you find itIf the signs line up, follow CPSC and HUD's identification and remediation guidance and get a specialist inspection. A Senate hearing record described the Louisiana court remediation protocol at about $86 per square foot, more than $200,000 for a 2,400-square-foot home. No open settlement program was found.

Sources

5 verified sources, 4 primary. Each quote is copied word for word from the page linked.

  1. US CPSC Drywall Information CenterPrimary source

    (if drywall was installed between 2005 and 2009, must have at least two of the below. For installations between 2001 and 2004, at least four of the following conditions must be met:)

    cpsc.gov/safety-education/safety-education-centers/dr… (opens in a new tab)
  2. US CPSC Drywall Information CenterPrimary source

    the CPSC has received about 4,051 reports from residents in 44 states, the District of Columbia, American Samoa, and Puerto Rico

    cpsc.gov/safety-education/safety-education-centers/dr… (opens in a new tab)
  3. US CPSC status report, March 2010Primary source

    More than 90% of reports are from Florida (59%), Louisiana (20%), Mississippi (6%) and Alabama (5%) and Virginia (4%).

    cpsc.gov/s3fs-public/pdfs/blk_media_mar2010status.pdf (opens in a new tab)
  4. US Senate hearing record, S. Hrg. 112-348 (December 6, 2011)Primary source

    pegged at $86 per square foot. That would amount to more than $200,000 for a 2,400 square foot home

    govinfo.gov/content/pkg/CHRG-112shrg73876/html/CHRG-1… (opens in a new tab)
  5. Wikipedia, Chinese drywall (secondary)Reference

    Sources estimated that from 60,000 to 100,000 homes could be affected.

    en.wikipedia.org/wiki/Chinese_drywall (opens in a new tab)

A source misread, out of date or missing?Report an error on this page

Applies to houses built

Open the full report for a year to see everything else houses of that age have in common.

A guide to what to look for. Not an inspection.