Square D arc-fault (AFCI) breakers (2004 recall)
Some Square D arc-fault breakers from 2004, the ones with a blue test button, may not catch the sparking they were installed to catch.
- Houses built
- in 2004
- Dates from
- Court record: Dates come from a court settlement or a product recall.
- How common
- No reliable count exists
- Priority
- Good to know
- Mainly about
- Safety
- Where to look
- Electrical panel
What it is
About 700,000 Square D QO and Homeline arc-fault breakers made after March 1, 2004 and sold from March to September 2004 were recalled because they may not detect an arc fault. CPSC says they still work as regular circuit breakers. They were put in to meet the 2002 electrical code rule for bedroom circuits.
How sure the dates are
Court record: Dates come from a court settlement or a product recall.Dates come from a court settlement or a product recall. What the labels mean
How common it is
No reliable count existsAbout 700,000 units were recalled; no count of affected homes exists.
The years
Houses built in 2004 may have it.
- Earliest
- 2004A fixed date, set by a rule, a recall or a court record.
- Most likely
- Not narrowedSources give no narrower window, so treat every year in the range alike.
- Latest
- 2004A fixed date, such as a ban, a recall or a code change.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
How to check
Open the panel door and look for Square D QO or Homeline breakers marked AFCI or arc fault, usually on bedroom circuits.
Note whether the test button is blue.
Have an electrician read the date code stamped in red on the breaker label: CN, DN, EN, FN, GN, HN or JN are the recalled codes.
- Electrical panel
What to do
If you find itIf they match, contact Schneider Electric (Square D) about replacement, and check the recall notice for current details.
Sources
5 verified sources, 5 primary. Each quote is copied word for word from the page linked.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2005/cpsc-schneider-electric-north-a… (opens in a new tab)The recalled units were manufactured after March 1, 2004, and have a blue test button.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2005/cpsc-schneider-electric-north-a… (opens in a new tab)About 700,000
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2005/cpsc-schneider-electric-north-a… (opens in a new tab)They are required to be installed in bedroom circuits in accordance with the 2002 National Electrical Code.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2005/cpsc-schneider-electric-north-a… (opens in a new tab)Although the AFCIs will function as regular circuit breakers, they may not detect an arc fault, posing a safety risk to consumers.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2005/cpsc-schneider-electric-north-a… (opens in a new tab)Electrical distributors and retailers sold the AFCIs between March 2004 and September 2004
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.