Year Built

Report · houses built in

What a house built in 2019 often has

Age
7yrs
On record
6
Check first
0
Built without
0

Choose one to hide issues that only apply elsewhere.

About your house

A few optional answers make this report specific to one house.

0 of 11 questions answered.

Headline finding

Little is known to be wrong with houses this new.

Nothing in the record marks 2019 as a problem year for materials or methods; 6 items below still apply, mostly things any house can have. What matters now is upkeep: 6 parts are already in their replacement window.

First to come due

  1. Sump pumpin its window
  2. Caulking (interior and exterior)in its window
  3. Exterior paintin its window
  4. Central air conditionerin its window
  5. Tank water heaterin its window

Where 2019 sits among every issue on record

Point at a band to read it · drag or use the arrow keys to compare years
What the 2019 line crosses6 bands
Electrical
Nothing for 2019
Plumbing
Nothing for 2019
Hazardous materials
Nothing for 2019
Roof, walls & windows
Nothing for 2019
  • Solid: most likely years
  • Faded edge: approximate date
  • Sharp edge: legal or recall date
  • Hatched: protection missing
  • Check first

What’s due at this age

A 2019 house is 7 years old. Here is where its parts stand against their typical life, and which ones have certainly been replaced by now.

In their window
6
Past life, if original
2
Due within 5 yrs
9
Replaced by now
0

Know when something was last replaced? Enter the year (or a decade, like 2010s) and we’ll show where that part stands. It stays on this device only.

In the replacement window now

6

If these are still the originals, they are inside their typical service life range. Worth budgeting for.

  • Sump pumpBasement & foundation · lasts ~7 yrs

    It only matters when it rains hard, so test it before storm season by pouring water in the pit. A battery backup helps if the power fails.

    ~7 yrsIn its windowif original
  • Caulking (interior and exterior)Exterior walls · lasts 5–10 yrs

    Cracked or pulled-away caulk lets water in around windows, trim and tubs. It is cheap to redo and prevents costly rot.

    5–10 yrsIn its windowif original
  • Exterior paintExterior walls · lasts 7–10 yrs

    Surface preparation and paint quality matter most; sun shortens life. Peeling and chalking mean it is due before the wood underneath is exposed.

    7–10 yrsIn its windowif original
  • Central air conditionerHeating & cooling · lasts 7–15 yrs

    Hot or coastal climates and neglected filters shorten life. Weak cooling, ice on the lines and frequent repairs are the signs.

    7–15 yrsIn its windowif original
  • Tank water heaterWater heater · lasts 6–15 yrs

    Mineral-rich water shortens life. Rust at the base, moisture in the pan or rumbling mean it is failing, and a burst tank can flood the area, so replace one past its range before it leaks.

    6–15 yrsIn its windowif original
  • Washing machineBathroom · lasts 5–15 yrs

    Wide range because use varies. Leaks, violent shaking and rust-colored water mean it is failing; check the supply hoses and drain pan.

    5–15 yrsIn its windowif original

Past typical life, if still original

2

Older than the usual range, but not so old that an original is unlikely. Worth finding out whether they have been replaced.

  • Carbon monoxide alarmWhole house · lasts ~5 yrs
    ~5 yrs2 yrs pastif original
  • Dryer vent (plastic)Whole house · lasts ~5 yrs
    ~5 yrs2 yrs pastif original

Coming due in the next five years

9

Not yet, but close enough to plan for.

  • CarpetWalls, ceilings & floors · lasts 8–10 yrs
    8–10 yrsIn 1 yrif original
  • DishwasherKitchen · lasts ~9 yrs
    ~9 yrsIn 2 yrsif original
  • RefrigeratorKitchen · lasts 9–13 yrs
    9–13 yrsIn 2 yrsif original
  • Deck framingDeck & yard · lasts 10–30 yrs
    10–30 yrsIn 3 yrsif original
  • Garage door openerGarage · lasts 10–15 yrs
    10–15 yrsIn 3 yrsif original
  • Heat pumpHeating & cooling · lasts 10–15 yrs
    10–15 yrsIn 3 yrsif original
  • Smoke alarmWhole house · lasts ~10 yrs
    ~10 yrsIn 3 yrsif original
  • Tankless water heaterWater heater · lasts 10–20 yrs
    10–20 yrsIn 3 yrsif original
  • Garbage disposalKitchen · lasts ~12 yrs
    ~12 yrsIn 5 yrsif original
Further out36
  • Clothes dryerWhole houselasts ~13 yrsin 6 yrs
  • Electric rangeKitchenlasts 13–15 yrsin 6 yrs
  • Aluminum windowsWindowslasts 15–20 yrsin 8 yrs
  • Asphalt drivewayDeck & yardlasts 15–20 yrsin 8 yrs
  • Faucets and spray hoseBathroomlasts 15–20 yrsin 8 yrs
  • Flat roof (EPDM rubber)Rooflasts 15–25 yrsin 8 yrs
  • Forced-air furnaceHeating & coolinglasts 15–25 yrsin 8 yrs
  • Gas rangeKitchenlasts 15–17 yrsin 8 yrs
  • Septic systemDrains & sewerlasts 15–40 yrsin 8 yrs
  • Well pumpWater pipeslasts ~15 yrsin 8 yrs
  • Wood deck boardsDeck & yardlasts ~15 yrsin 8 yrs
  • Aluminum gutters and downspoutsRooflasts 20–40 yrsin 13 yrs
  • Asphalt shingle roof (3-tab)Rooflasts ~20 yrsin 13 yrs
  • Flat roof (modified bitumen)Rooflasts ~20 yrsin 13 yrs
  • Garage doorGaragelasts 20–25 yrsin 13 yrs
  • Vinyl or fiberglass windowsWindowslasts 20–40 yrsin 13 yrs
  • Water softenerWater pipeslasts ~20 yrsin 13 yrs
  • Vinyl floorWalls, ceilings & floorslasts ~25 yrsin 18 yrs
  • Wood shake roofRooflasts ~25 yrsin 18 yrs
  • Asphalt shingle roof (architectural)Rooflasts ~30 yrsin 23 yrs
  • GFCI outletsKitchenlasts ~30 yrsin 23 yrs
  • Wood windowsWindowslasts ~30 yrsin 23 yrs
  • Boiler (hot-water or steam)Heating & coolinglasts ~40 yrsin 33 yrs
  • Chimney flue tileChimneylasts 40–120 yrsin 33 yrs
  • Concrete walkwayDeck & yardlasts 40–50 yrsin 33 yrs
  • Metal roofRooflasts 40–80 yrsin 33 yrs
  • Cast-iron drain pipe (below ground)Drains & sewerlasts 50–60 yrsin 43 yrs
  • Copper water supply linesWater pipeslasts 50–70 yrsin 43 yrs
  • Electrical service panelElectrical panellasts ~60 yrsin 53 yrs
  • Heating and cooling ductworkHeating & coolinglasts 60–100 yrsin 53 yrs
  • Vinyl sidingExterior wallslasts ~60 yrsin 53 yrs
  • Clay or concrete tile roofRooflasts ~100 yrsin 93 yrs
  • Fiber cement sidingExterior wallslasts ~100 yrsin 93 yrs
  • Fiberglass exterior doorWhole houselasts ~100 yrsin 93 yrs
  • Hardwood floorWalls, ceilings & floorslasts ~100 yrsin 93 yrs
  • ToiletsBathroomlasts ~100 yrsin 93 yrs

Typical lives from InterNACHI Standard Estimated Life Expectancy Chart for Homes, CPSC, U.S. Department of Energy (hosted guide), US Department of Energy, Energy Saver Guide (2022), InterNACHI, Smoke Alarm Inspection, US EPA, New Homebuyer's Guide to Septic Systems, InterNACHI and U.S. Consumer Product Safety Commission. Real lives vary with climate, quality and upkeep.

Everything else, by part of the house

Materials and products often installed in 2019. Open any row for how to check.

Where to look. Each number counts the items in this report for that part of the house.

Heating, cooling & chimney2

  • Lochinvar, A. O. Smith and State condensing boilers (2020 recall)

    2016–2020Some high-efficiency home boilers sold from 2016 to 2020 have a flue seal that can wear out and let carbon monoxide escape.

    Some high-efficiency home boilers sold from 2016 to 2020 have a flue seal that can wear out and let carbon monoxide escape.

    Read the full entry →

    2016–2020

    Court record: Dates come from a court settlement or a product recall.No reliable count exists

    How to check

    1. Check whether the boiler is branded Lochinvar, A. O. Smith or State Proline.
    2. Find the rating plate on the outer jacket or the underside of the front panel, with the model and serial number.
    3. The notice lists serial numbers 103475818 through 115078306 and model families such as ACB, KHB, SCB and WHL. Compare yours with the full list.

    If you find itLook up the serial number at waterheaterrecall.com, as the notice directs. If it matches, contact Lochinvar or your installer about the repair and check whether it is still offered. Keep a working CO alarm near the boiler and bedrooms.

    How commonAbout 34,300 units were recalled in the US; no count of affected homes exists.

    Keep in mindBoilers are replaced in older houses too, so the label matters more than build year. Later boiler recalls from other makers exist but were not checked for this guide.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 5 sources →
  • R-410A air conditioners and heat pumps

    2010–2025 · peakCentral AC installed from about 2010 to 2025 may well run on R-410A, a refrigerant that new equipment is now moving away from.

    Central AC installed from about 2010 to 2025 may well run on R-410A, a refrigerant that new equipment is now moving away from.

    Read the full entry →

    2010–20252019 is in the peak years

    Federal rule: Dates come from a federal rule or a model building code.Likely

    How to check

    1. Find the nameplate on the outdoor unit.
    2. Look for the refrigerant listed: R-410A, R-22, or a newer type such as R-454B or R-32.

    If you find itNothing is required for a working system. When it is time to replace it, ask the contractor which refrigerant the new system uses and whether any other parts need changing.

    How commonNo count of homes exists. EPA barred making new equipment with R-22 from January 1, 2010; that most systems since then use R-410A is an inference, not a sourced figure.

    Keep in mindThe 2010 start is approximate. EPA's installation rules depend on when a system's parts were made, so check EPA's current page before relying on a cutoff. Many older houses got an R-410A system as a replacement.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 4 sources →

Roof & attic1

  • Factory-built roof trusses

    Built 1955 or laterIf your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.

    If your attic is a web of diagonal 2x4s joined by toothed metal plates, the roof is built from factory trusses, and cutting even one can badly weaken it.

    Read the full entry →

    Built 1955 or later

    Approximate era: Dates are an approximate era drawn from trade and reference sources.No reliable count exists

    How to check

    1. In the attic, look for diagonal 2x4s forming W or M shapes, joined by toothed galvanized steel plates.
    2. Rafters, by contrast, are larger boards running from the ridge to the wall with open space between.
    3. Look for cut or notched members and plates that have backed out of the wood.

    If you find itNothing is needed unless trusses are damaged or altered. Before any attic conversion, skylight or other change that touches a truss, get an engineer's design.

    How commonNo reliable count exists for houses by year built.

    Keep in mindTruss use grew over decades, and many houses still use rafters, especially custom homes and complex roofs. A reference source dates the connector plate to 1955.

    Details and 1 source →

Foundation & basement1

  • Engineered I-joist floors

    Built 1970 or later · peakBy 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.

    By 2005 about half of wood light-frame floors used engineered I-joists, which perform well day to day but can fail quickly in a fire if left exposed.

    Read the full entry →

    Built 1970 or later2019 is in the peak years

    Approximate era: Dates are an approximate era drawn from trade and reference sources.Possible

    How to check

    1. Look up at the basement or garage ceiling for I-shaped joists: a thin OSB or plywood web with small lumber flanges top and bottom.
    2. They are usually printed with the maker's brand name.
    3. If you can see them, they are unprotected from below.

    If you find itConsider covering exposed I-joists with drywall, and make sure working smoke alarms cover every level, including the basement.

    How commonWikipedia: about 50% of wood light-frame floors used I-joists as of 2005.

    Keep in mindNewer model codes are reported to require covering them, but that was not confirmed and code adoption varies by state. The hazard applies only where the joists are exposed.

    Details and 2 sources →

Whole house2

  • Kidde TruSense smoke alarms (2021 recall)

    2019–2020Some Kidde TruSense alarms sold in 2019 and 2020 can fail to alert to a fire.

    Some Kidde TruSense alarms sold in 2019 and 2020 can fail to alert to a fire.

    Read the full entry →

    2019–2020

    Court record: Dates come from a court settlement or a product recall.No reliable count exists

    How to check

    1. Look for the TruSense logo or the words 'AMBER=FAULT' printed on the front of each alarm.
    2. Take it down and read the model number on the back.
    3. Recalled models: 2040-DSR, 2050-DS10, 2060-ASR, 2070-VDSCR, 2070-VASCR, 2070-VDSR and 2070-VASR.

    If you find itIf it matches, contact Kidde for the free replacement alarm. Check the recall notice for current details.

    How commonAbout 226,000 units were recalled; no count of affected homes exists.

    Keep in mindThese were sold as replacements as well as for new houses, so check the label in a house of any age.

    Year predicts poorlyThis is often added to older houses later, so check whatever the build year.

    Details and 2 sources →
  • Home fire sprinklers

    Built 2011 or laterCACalifornia has required fire sprinklers in new one- and two-family homes since 2011, so newer California houses generally have small sprinkler heads in the ceilings.

    California has required fire sprinklers in new one- and two-family homes since 2011, so newer California houses generally have small sprinkler heads in the ceilings.

    Read the full entry →

    Built 2011 or later

    Federal rule: Dates come from a federal rule or a model building code.Likely

    How to check

    1. Look up: small sprinkler heads, often under flat white cover plates, in the ceiling of every room.
    2. Find the riser, a pipe with a gauge and flow switch, near the water main or in the garage.

    If you find itKeep the control valve open and never paint over a sprinkler head. Replace any head that has been painted or blocked.

    How commonCalifornia has required sprinklers in all new residential construction since 2011 (Wikipedia). Outside places that require them, they are uncommon in houses.

    Keep in mindSome cities outside California also require sprinklers by local ordinance. Houses permitted before 2011 but finished later may not have them.

    Details and 2 sources →

Your place

Add a ZIP code for a few sourced facts about where the house stands: the homes around it, radon, climate and flood maps. All optional.

Looking up a ZIP code needs JavaScript. Everything else on this page works without it.

Part two

The year in context

What was changing around 2019, how much the country was building, how houses of this era stand today and what homes were like then. All of it describes houses in general, never this one.

The year in context · events

Around 2019: what was changing in homebuilding

What happened in 2019 first, then the nearest dated events within 2 years either side. Each comes with its source and how strong that source is.

4 events on a 2016–2022 axis; the tagged line is 2019. Filled rings are dated to 2019. Dashed rings are approximate (circa).

In 2019

  1. 2019

    Hazardous materials

    EPA rule on discontinued asbestos uses

    In April 2019 EPA finalized a rule so discontinued asbestos products cannot return to the market without review.

    U.S. Environmental Protection AgencyPrimary source
    Quote
    “April 2019 Restrictions on Discontinued Uses of Asbestos Rule” U.S. Environmental Protection Agency

Nearby, 2017 to 2020within 2 years of 2019

  1. 2017

    Industry

    Typical new house in 2017

    In 2017, 93 percent of new single-family houses completed had air conditioning, 41 percent used heat pumps, and 37 percent had three or more bathrooms.

    U.S. Census Bureau, Characteristics of New Housing 2017 (annual tables)Primary source
    Quotes
    “2017 795 742 53 100 93 7” U.S. Census Bureau, Characteristics of New Housing 2017 (annual tables)
    “2017 795 451 323 9 13 100 57 41 1 2” U.S. Census Bureau, Characteristics of New Housing 2017 (annual tables)
  2. 2018

    Materials

    Formaldehyde emission standards for composite wood take effect

    The EPA formaldehyde emission standards for plywood, particleboard and fiberboard came into force June 1, 2018.

    U.S. Environmental Protection AgencyPrimary source
    Quote
    “The formaldehyde emission standards come into force beginning June 1, 2018.” U.S. Environmental Protection Agency
  3. 2020

    Plumbing

    EPA final lead-free pipes, fixtures, solder and flux rule

    On September 1, 2020 EPA published the final regulation on lead-free pipes, fittings, fixtures, solder and flux.

    U.S. Environmental Protection AgencyPrimary source
    Quote
    “On September 1, 2020, the U.S. Environmental Protection Agency (EPA) published the final regulation” U.S. Environmental Protection Agency

Events come from a researched timeline of 150 dated changes to US homebuilding, each checked against the quoted source. Primary source is a government or standards body, Trade reference a trade body and Reference a general reference such as Wikipedia. A date is when something began or became required, not when every builder followed.

The year in context · building

Housing that year

How many new homes were started across the US in 2019, against every year since 1889. It is the whole country’s building, houses and apartments, not a count of houses like this one.

New homes started · 2019 · US

About 1.29 million new homes (houses and apartments) were started in 2019, the most since 2007, and 3% more than in 2018.

Started
1.29 million
Median new house price
$321,5002019 $
In one-family buildings
69%
  • Before 1959 the counts are historical estimates: Historical Statistics of the United States reconstructed them from building permits and other records, in series that change method in 1920, 1930 and 1945. They leave out farm housing. The figures here were transcribed by hand from a scanned copy and checked against the table’s own totals.
  • From 1959 the count is the Census Bureau’s privately owned housing units started; public housing is not in it. Mobile homes, conversions and temporary units are never counted.
  • The median new house price is in the dollars of 2019, not adjusted for inflation.

Source US Census Bureau, Historical Statistics of the United States, Colonial Times to 1970, Series N 156 (1889–1958); New Residential Construction, annual housing starts (1959–2025); New Residential Sales, median sales price of new houses sold.

As built · new houses of 2019

The typical new house of 2019

How new single-family houses completed in 2019 across the US were built, from the US Census Bureau’s Survey of Construction. These describe that year’s new houses, not this one, and a house may have been altered since.

Showing the whole US · choose your state above, or a region here

Region

New houses · 2019 · US

Most often: one or two stories, on a slab or other foundation, stucco or vinyl siding outside, gas heat and air-conditioning.

Median size
2,301sq ft
Completed
903,000houses

Median size, sq ft

  1. Floors

    48% 1 story

    • 1 story48%
    • 2 stories47%
    • 3 or more5%
    • Floors are counted two ways: through 2008, 1 story, 2 or more, and split-level; from 2009, split-level and 1½-story houses count as 2 stories and 3 or more is separate. Only “1 story” is roughly comparable across the change.

    1 story, over time

  2. Foundation

    64% Slab or other (piers, pilings)

    • Basement23%
    • Slab or other64%
    • Crawl space14%
    • The Census counts slabs together with other foundations such as piers and pilings, so this is “slab or other”, never slab alone.

    Slab or other, over time

  3. Outside walls

    27% Stucco

    • Brick20%
    • Wood5%
    • Stucco27%
    • Vinyl siding25%
    • Fiber cement21%
    • Other2%
    • Aluminum siding is counted inside “other”, with block and stone.

    Stucco, over time

  4. Heating fuel

    56% Gas (natural or bottled)

    • Gas56%
    • Electricity43%
    • Oil or other1%
    • From 2014 the Census stopped publishing oil separately; oil and kerosene are counted with “other or none”.
    • Gas includes bottled gas and propane as well as natural gas.

    Gas (natural or bottled), over time

  5. Heating system

    57% Forced-air furnace

    • Forced-air furnace57%
    • Heat pump41%
    • Hot water or steam1%
    • Other or none1%

    Forced-air furnace, over time

  6. Air-conditioning

    94% With air-conditioning

    • With air-conditioning94%
    • Without6%

    With air-conditioning, over time

  7. Bedrooms

    46% 3 bedrooms

    • 2 or fewer11%
    • 346%
    • 4 or more43%

    3 bedrooms, over time

  8. Bathrooms

    34% 2 bathrooms

    • 1½ or fewer3%
    • 234%
    • 2½29%
    • 3 or more33%

    2 bathrooms, over time

  9. Garage

    65% 2-car garage

    • 1-car garage7%
    • 2-car garage65%
    • 3+ car garage19%
    • Carport1%
    • None7%

    2-car garage, over time

  10. Fireplaces

    61% No fireplace

    • None61%
    • 134%
    • 2 or more5%

    No fireplace, over time

  • These are new single-family houses completed that year in that region, including houses built for rent. They describe how houses were being built, not any one house.
  • These are survey estimates. Sampling error is larger for older years, for single regions and for small categories; “withheld” marks cells the Census did not publish.
  • Roofing is not recorded by this survey. Houses were not counted by state, so a region is the closest view.

Source US Census Bureau, Survey of Construction (Characteristics of New Housing), houses completed. Tables: Stories, Foundation, Exterior Wall Material, Heating Fuel, Heating System, Air-Conditioning, Bedrooms, Bathrooms, Parking Facility, Fireplaces, Square feet.

As they stand today · houses built 2010 or later

Houses of 2010 or later, today

The typical new house above is how houses were built in 2019. This is the other view: houses built 2010 or later that are still standing and lived in, as they are now, after decades of new roofs, new siding and renovation. Not as they were built.

Showing the whole US · detached single-family houses

Region

Roofs today · built 2016 to 2020 · US

About 4 in 5 surviving houses built 2016 to 2020 across the US have asphalt shingle roofs today, and about 1 in 10 has clay tile.

Roof material as reported in 2020. Most roofs have been replaced at least once since these houses were built, so this is what is on them now.

Homes sampled
481
Average size
2,653sq ft
  • Asphalt shingles78%
  • Metal5%
  • Wood shakes2%
  • Slate1%
  • Clay tile9%
  • Concrete tile3%
  • Other1%

481 homes sampled · EIA RECS 2020

Asphalt shingles, by era built

Roof, walls, window glass and stories come from the EIA survey, which can only group houses built 2016 to 2020. Everything else comes from the American Housing Survey’s finer band: houses built 2010 or later.

The shell

  1. Outside walls

    46% Siding: vinyl, aluminum, fiber cement or steel

    • Siding46%
    • Brick22%
    • Wood6%
    • Stucco20%
    • Stone1%
    • Concrete block4%
    • Other1%

    481 homes sampled · EIA RECS 2020

    Siding, by era built

  2. Window glass

    87% Double-pane

    • Single-pane10%
    • Double-pane87%
    • Triple-pane3%

    481 homes sampled · EIA RECS 2020

    Double-pane, by era built

  3. Foundation

    58% Slab

    • Full basement23%
    • Part basement4%
    • Crawl space14%
    • Slab58%
    • Other1%

    2,654 homes sampled · AHS 2023

    Slab, by era built

  4. Stories

    57% 1 story

    • 1 story57%
    • 2 stories41%
    • 3 or more2%
    • Split-level1%

    481 homes sampled · EIA RECS 2020

    1 story, by era built

Heating and cooling

  1. Main heating fuel

    50% Electricity

    • Gas42%
    • Electricity50%
    • Oil1%
    • Propane6%
    • Wood1%
    • Other1%

    2,654 homes sampled · AHS 2023

    Electricity, by era built

  2. Main heating equipment

    76% Forced warm-air furnace

    • Furnace76%
    • Boiler1%
    • Heat pump17%
    • Electric baseboard1%
    • Wall or room heater3%
    • Stove or fireplace1%
    • Other or none1%

    2,654 homes sampled · AHS 2023

    Forced warm-air furnace, by era built

  3. Air-conditioning

    94% Central air

    • Central air94%
    • Room units only3%
    • None3%

    2,654 homes sampled · AHS 2023

    Central air, by era built

The rooms

  1. Bathrooms

    40% Three or more

    • No full bath<0.5%
    • 14%
    • 1½2%
    • 228%
    • 2½26%
    • 3+40%

    2,654 homes sampled · AHS 2023

    Three or more, by era built

  2. Fireplace

    51% No usable fireplace

    • Usable fireplace49%
    • None51%

    2,654 homes sampled · AHS 2023

    No usable fireplace, by era built

  3. Size

    45% 2,500 sq ft or more

    • Under 1,0002%
    • 1,000–1,49910%
    • 1,500–1,99922%
    • 2,000–2,49921%
    • 2,500+45%

    2,539 homes sampled · AHS 2023

    2,500 sq ft or more, by era built

  4. Garage or carport

    94% Garage or carport

    • Garage or carport94%
    • Neither7%

    2,642 homes sampled · AHS 2023

    Garage or carport, by era built

  • Surviving detached single-family houses as they are today, by the decade their occupants say they were built. Roofs, siding, windows and heating include every replacement since. Houses that were torn down are not in it, so this is not how the era built.
  • In the Census Bureau’s words, “some of the home characteristics … may have been more recent additions or installations and did not come with the home when it was originally built.”
  • Survey estimates from samples of homes: a band with fewer than 30 sampled homes is never shown, and one with fewer than 100 is marked small sample. The EIA survey covers occupied primary homes only; the American Housing Survey also counts vacant ones.

Source US Energy Information Administration, Residential Energy Consumption Survey 2020, public microdata (roof, walls, window glass, stories, size); US Census Bureau and HUD, American Housing Survey 2023, national public use file (everything else); shares computed from the public microdata with the surveys’ weights. Caveat quoted from Census working paper 2011-18.

The year in context · the country

The country’s homes today

The decennial census stopped collecting these details after 2000, so for a house built in 2019 there is only today’s count.

Housing facts, the US
FactUS
Homes built in the 2010s still standing todayACS 2020-2024, B2503413.6 million 9.4% of homes
Half of all homes standing today were built beforethe median year builtACS 2020-2024, B250351980

Today’s count is the US Census Bureau’s American Community Survey, 2020 to 2024, which includes vacant homes and dates them by what residents report. Choose your state above to see it beside the US.

See something in the 2019 report that looks wrong?Report an error on this page