Often present · Fire & life safety
Kidde dual-sensor smoke alarms with a yellow cap (2018 recall)
A yellow cap left on at the factory can block one of the two sensors in some Kidde alarms from 2016 and 2017.
- Houses built
- 2016–2018
- Dates from
- Court record: Dates come from a court settlement or a product recall.
- How common
- No reliable count exists
- Priority
- Worth a look
- Mainly about
- Safety
- Where to look
- Whole house
What it is
Kidde recalled about 452,000 dual-sensor smoke alarms, the hard-wired PI2010 and battery-powered PI9010, with date codes from September 10, 2016 to October 13, 2017. A yellow cap left on during manufacture can cover one sensor, so the alarm may not detect smoke properly. You can see the cap through a side opening.
How sure the dates are
Court record: Dates come from a court settlement or a product recall.Dates come from a court settlement or a product recall. What the labels mean
How common it is
No reliable count existsAbout 452,000 units were recalled in the US; no count of affected homes exists.
The years
Houses built from 2016 to 2018 may have it. It is most likely in houses built 2016 to 2017.
- Earliest
- 2016A fixed date, set by a rule, a recall or a court record.
- Most likely
- 2016–2017The years it is most common: the solid part of the band.
- Latest
- 2018A fixed date, such as a ban, a recall or a code change.
- Solid: most likely years
- Faded edge: approximate date
- Sharp edge: legal or recall date
- Hatched: protection missing
- Check first
Year predicts poorly
This was often added to older houses later, so check for it whatever the build year.
How to check
Look for alarms with 'KIDDE' printed on the front.
Take one down and read the model (PI2010 or PI9010) and date code on the back.
If the date code is between 2016 Sep. 10 and 2017 Oct. 13, look through the side opening for a yellow cap.
- Whole house
What to do
If you find itIf it matches, contact Kidde for the free replacement listed in the notice, and check the notice for current details.
Sources
3 verified sources, 3 primary. Each quote is copied word for word from the page linked.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2018/Kidde-Recalls-Dual-Sensor-Smoke… (opens in a new tab)A yellow cap left on during the manufacturing process can cover one of the two smoke sensors
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2018/Kidde-Recalls-Dual-Sensor-Smoke… (opens in a new tab)About 452,000 in the U.S.
U.S. Consumer Product Safety CommissionPrimary source
cpsc.gov/Recalls/2018/Kidde-Recalls-Dual-Sensor-Smoke… (opens in a new tab)from September 2016 through January 2018 for between $20 and $40
A source misread, out of date or missing?Report an error on this page
Applies to houses built
Open the full report for a year to see everything else houses of that age have in common.
A guide to what to look for. Not an inspection.